Biomechanical effects of calcar screws and bone block augmentation on medial support in locked plating of proximal humeral fractures

被引:74
作者
Katthagen, Jan Christoph [1 ]
Schwarze, Michael [2 ]
Meyer-Kobbe, Josefin [1 ]
Voigt, Christine [1 ]
Hurschler, Christof [2 ]
Lill, Helmut [1 ]
机构
[1] Diakoniekrankenhaus Friederikenstift gGmbH, Dept Trauma & Reconstruct Surg, D-30169 Hannover, Germany
[2] MHH, Lab Biomech & Biomat, D-30625 Hannover, Germany
关键词
Proximal humerus; Fracture; Medial support; Calcar screw; Dynamic locking screw; Bone augmentation; INTRAMEDULLARY FIBULAR ALLOGRAFT; LOCKING-PLATE; ENDOSTEAL IMPLANT; UNSTABLE FRACTURES; MINERAL DENSITY; OPEN REDUCTION; JOINT LOADS; IN-VITRO; FIXATION; GRAFT;
D O I
10.1016/j.clinbiomech.2014.06.008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The objective of this study was to investigate the biomechanical effects of medial fracture gap augmentation in locked plating of an unstable 2-part proximal humeral fracture with calcar screws and insertion of a corticocancellous bone block Furthermore the mechanical behavior of dynamic locking screws in the non-parallel arrangement of a proximal humeral plate was of interest. Methods: Thirty-two fresh frozen humeri were randomized in four equal groups. An unstable 2-part fracture was fixed by locked plating in all specimens. The basic screw setup was supplemented by additional calcar screws in one group. Humeral head screws were replaced by dynamic locking screws in a second group. The third group featured an additional corticocancellous femoral head allograft. Assessment of stiffness was followed by cyclic loading and load to failure tests. Resulting stiffness, fracture gap deflection and ultimate load were compared utilizing Bonferroni corrected t-test for independent samples. Findings: The mechanical effect of additional calcar screws was non-significant as compared to the basic screw configuration whereas bone block insertion significantly increased construct stiffness and failure load. The use of dynamic locking screws did not significantly reduce construct stiffness when compared to conventional locking screws. Interpretation: Additional calcar screws alone did not improve the initial biomechanical properties of an unstable 2-part proximal humeral fracture model. However bone block augmentation appeared to be a reliable alternative of additional bony support by raising stiffness and failure load. Dynamic locking screws did not show their expected dynamic component when used in a non-parallel arrangement. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:735 / 741
页数:7
相关论文
共 50 条
[21]   Effect of Calcar Screw Use in Surgical Neck Fractures of the Proximal Humerus With Unstable Medial Support: A Biomechanical Study [J].
Bai, Lu ;
Fu, Zhongguo ;
An, Shuai ;
Zhang, Peixun ;
Zhang, Dianying ;
Jiang, Baoguo .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2014, 28 (08) :452-457
[22]   Results of biological restoration of varus impacted proximal humeral fracture and stabilization with locked plate and calcar screws [J].
Sharaby, Mohamed M. F. .
CURRENT ORTHOPAEDIC PRACTICE, 2016, 27 (05) :524-529
[23]   Locked Plating of Proximal Humeral Fractures: Is Function Affected by Age, Time, and Fracture Patterns? [J].
Jones, Clifford B. ;
Sietsema, Debra L. ;
Williams, Daniel K. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (12) :3307-3316
[24]   Complications of locked plating for proximal humeral fractures-are we getting any better? [J].
Haasters, Florian ;
Siebenbuerger, Georg ;
Helfen, Tobias ;
Daferner, Mark ;
Boecker, Wolfgang ;
Ockert, Ben .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (10) :E295-E303
[25]   Inferomedial cortical bone contact and fixation with calcar screws on the dynamic and static mechanical stability of proximal humerus fractures [J].
Zhang, Xiaofeng ;
Huang, Junwu ;
Zhao, Lin ;
Luo, Yi ;
Mao, Hanxin ;
Huang, Yanfeng ;
Chen, Weibing ;
Chen, Qi ;
Cheng, Bangjun .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (1)
[26]   Reconstruction of proximal humeral fractures with a reduced number of screws and a reinforced bone substitute [J].
Cristofolini, Luca ;
Morellato, Kavin ;
Cavallo, Marco ;
Guerra, Enrico .
MEDICAL ENGINEERING & PHYSICS, 2020, 82 :97-103
[27]   How many cephalic locked screws are needed in valgus proximal humeral fractures? [J].
Moreno Figaredo, Victoria ;
Pons-Villanueva, Juan .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (10) :2370-2372
[28]   The clinical benefit of medial support screws in locking plating of proximal humerus fractures: a prospective randomized study [J].
Lei Zhang ;
Jinyou Zheng ;
Weiliang Wang ;
Guangmao Lin ;
Yijiang Huang ;
Jin Zheng ;
Ghamor-Amegavi Edem Prince ;
Guojing Yang .
International Orthopaedics, 2011, 35 :1655-1661
[29]   The clinical benefit of medial support screws in locking plating of proximal humerus fractures: a prospective randomized study [J].
Zhang, Lei ;
Zheng, Jinyou ;
Wang, Weiliang ;
Lin, Guangmao ;
Huang, Yijiang ;
Zheng, Jin ;
Prince, Ghamor-Amegavi Edem ;
Yang, Guojing .
INTERNATIONAL ORTHOPAEDICS, 2011, 35 (11) :1655-1661
[30]   Effects of medial support screws on locking plating of proxima humerus fractures in elderly patients: a retrospective study [J].
Shen, Pengcheng ;
Zhu, Yu ;
Zhu, Lifan ;
Li, Xiaolin ;
Xu, Yaozeng .
ANNALS OF TRANSLATIONAL MEDICINE, 2019, 7 (20)