Research on Fault Ride-Through Capacity Enhancement of FSWT Using Fault Current Limiters of Different Types and Impedance

被引:0
作者
Yuan, Jiaxin [1 ,2 ]
Lei, Yang [1 ]
Chen, Baichao [1 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
[2] Ohio State Univ, Elect & Comp Engn, Columbus, OH 43210 USA
来源
2015 IEEE POWER & ENERGY SOCIETY GENERAL MEETING | 2015年
关键词
Resistive-type fault current Iimiters(RFCL); reactor-type fault current limiters(LFCL); fault ride-through(FRT); fixed speed wind turbine(FSWT);
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper analyzed the method of using FCL to enhance FRT capacity of FSWT and compared the performance of resistive-type fault current Iimiters (RFCL) and reactor-type fault current Iimiters (LFCL) of different limiting impedance. The minimum required value of the impedance for maintaining stable operation of FSWT during fault is determined, as well as dynamic stable speed and critical clearing time (CCT). The method has been validated by transient studies in a simple system by PSCADIEMTDC. Simulation results demonstrate that the enhancement of FRT is related highly with the limiting impedance of FCL. The RFCL has the advantage of choosing limiting impedance and transient oscillate, while the LFCL with minimum required impedance has a better performance on the enhancement of FRT.
引用
收藏
页数:5
相关论文
共 10 条
[1]   Optimal Allocation of HTS-FCL for Power System Security and Stability Enhancement [J].
Alaraifi, Surour ;
El Moursi, M. S. ;
Zeineldin, H. H. .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (04) :4701-4711
[2]  
[Anonymous], 2003, ANAL DYNAMIC BEHAV E
[3]   Fault ride-through of large wind farms using series dynamic braking resistors (March 2007) [J].
Causebrook, Andrew ;
Atkinson, David J. ;
Jack, Alan G. .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (03) :966-975
[4]   Fault ride through capability enhancement for self-excited induction generator-based wind parks by installing fault current limiters [J].
El-Moursi, M. S. .
IET RENEWABLE POWER GENERATION, 2011, 5 (04) :269-280
[5]   Analysis of Transient Stability Enhancement of LV-Connected Induction Microgenerators by Using Resistive-Type Fault Current Limiters [J].
Emhemed, Abdullah Swissi ;
Tumilty, Ryan M. ;
Singh, Nand K. ;
Burt, Graeme M. ;
McDonald, James R. .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2010, 25 (02) :885-893
[6]   Improving Fault Ride-Through Capability of Fixed-Speed Wind Turbine by Using Bridge-Type Fault Current Limiter [J].
Firouzi, M. ;
Gharehpetian, G. B. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2013, 28 (02) :361-369
[7]   Robust STATCOM control for the stabilisation of fixed-speed wind turbines during low voltages [J].
Hossain, M. J. ;
Pota, H. R. ;
Ramos, R. A. .
RENEWABLE ENERGY, 2011, 36 (11) :2897-2905
[8]   Low voltage ride through of wind farms with cage generators: STATCOM versus SVC [J].
Molinas, Marta ;
Suul, Jon Are ;
Undeland, Tore .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (03) :1104-1117
[9]   Distributed Generation Interface to the CERTS Microgrid [J].
Nikkhajoei, Hassan ;
Lasseter, Robert H. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (03) :1598-1608
[10]   A Modified Bridge-Type Fault Current Limiter for Fault Ride-Through Capacity Enhancement of Fixed Speed Wind Generator [J].
Rashid, Gilmanur ;
Ali, Mohd. Hasan .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2014, 29 (02) :527-534