Radiation exposure using laser aiming guide in orthopaedic procedures

被引:14
作者
Harris, I [1 ]
Walker, PM [1 ]
Trieu, L [1 ]
机构
[1] Liverpool Hosp, Dept Orthopaed Surg, Liverpool, NSW, Australia
关键词
fluoroscopy; fractures; lasers; orthopaedic surgery; radiation dosage;
D O I
10.1046/j.1445-2197.2002.02406.x
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Ionizing radiation from intraoperative fluoroscopy presents a serious occupational health and safety concern to orthopaedic surgeons. The long-term effects of ionizing radiation are well known; they include damage to the eyes, increased risk of haematological malignancy and carcinomas throughout the body.(1-3) We studied the effect of using an attachable laser aiming guide on radiation exposure during intraoperative fluoroscopy. Methods: A prospective, randomized controlled trial was performed at a single institution. Eight hundred and eighty consecutive orthopaedic procedures involving fluoroscopy were randomized into two groups. One group had fluoroscopy without an aiming guide, the other group had fluoroscopy with the aiming guide. Total exposure time, number of exposures and the body region examined were recorded. Results: For most regions studied, no significant difference in exposure time or number of exposures was found. For hip fractures, use of the laser aiming device was associated with an increase in the number of exposures (P=0.035), but there was no significant difference in average exposure time (P=0.31). Use of the aiming device was associated with an increased number of exposures (P=0.0025) and an increased exposure time (P=0.0016) for examination of the wrist, but this may represent selection bias. Conclusion: Use of a laser aiming device during intraoperative fluoroscopy was not associated with decreased exposure to radiation.
引用
收藏
页码:349 / 351
页数:3
相关论文
共 16 条
[1]   THE RISK FROM RADIATION EXPOSURE DURING OPERATIVE X-RAY SCREENING IN HAND SURGERY [J].
ARNSTEIN, PM ;
RICHARDS, AM ;
PUTNEY, R .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1994, 19B (03) :393-396
[2]   IMPLEMENTATION OF THE 1990 RECOMMENDATIONS OF ICRP IN THE COUNTRIES OF THE EUROPEAN-COMMUNITY [J].
CLARKE, RH ;
STATHER, JW .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 1993, 32 (02) :151-161
[3]  
COETZEE JC, 1992, S AFR MED J, V81, P312
[4]   A simple laser guide to reduce the screening time during the insertion of dynamic hip screws [J].
Conn, KS ;
Hallett, JP .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1998, 29 (07) :539-541
[5]   Evaluation of thyroid shields for reduction of radiation exposure to orthopaedic surgeons [J].
Dewey, P ;
Incoll, I .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1998, 68 (09) :635-636
[6]   RADIATION EXPOSURE TO THE HANDS OF ORTHOPEDIC SURGEONS DURING PROCEDURES UNDER FLUOROSCOPIC X-RAY CONTROL [J].
GOLDSTONE, KE ;
WRIGHT, IH ;
COHEN, B .
BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (790) :899-901
[7]   HISTORY, CURRENT STATUS, AND TRENDS OF RADIATION PROTECTION STANDARDS [J].
HENDEE, WR .
MEDICAL PHYSICS, 1993, 20 (05) :1303-1314
[8]   RADIATION EXPOSURE TO THE SURGEON DURING CLOSED INTERLOCKING INTRAMEDULLARY NAILING [J].
LEVIN, PE ;
SCHOEN, RW ;
BROWNER, BD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1987, 69A (05) :761-766
[9]   Radiation exposure to the orthopaedic surgical team during fluoroscopy: "How far away is far enough?" [J].
Mehlman, CT ;
DiPasquale, TG .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (06) :392-398
[10]  
MILLER ME, 1983, J BONE JOINT SURG AM, V65, P1