Design considerations for a time-resolved tomographic diagnostic at DARHT

被引:1
|
作者
Kaufman, Morris I. [1 ]
Frayer, Daniel [1 ]
Dreesen, Wendi [1 ]
Johnson, Douglas [1 ]
Meidinger, Alfred [1 ]
机构
[1] NSTec, Los Alamos Operat, 182 E Gate Dr, Los Alamos, NM 87544 USA
来源
NOVEL OPTICAL SYSTEMS DESIGN AND OPTIMIZATION IX | 2006年 / 6289卷
关键词
tomography; image tilt; optomechanical; mechanism design; automation; calibration;
D O I
10.1117/12.681157
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An instrument has been developed to acquire time-resolved tomographic data from the electron beam at the DARHT [Dual-Axis Radiographic Hydrodynamic Test] facility at Los Alamos National Laboratory. The instrument contains four optical lines of sight that view a single tilted object. The lens design optically integrates along one optical axis for each line of sight. These images are relayed via fiber optic arrays to streak cameras, and the recorded streaks are used to reconstruct the original two-dimensional data. Installation of this instrument into the facility requires automation of both the optomechanical adjustments and calibration of the instrument in a constrained space. Additional design considerations include compound tilts on the object and image planes.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Fielding of a time-resolved tomographic diagnostic
    Frayer, Daniel
    Cox, Brian
    Dreesen, Wendi
    Johnson, Douglas
    Jones, Michael
    Kaufman, Morris
    NOVEL OPTICAL SYSTEMS DESIGN AND OPTIMIZATION XI, 2008, 7061
  • [2] Time-Resolved Tomographic Quantification of the Microstructural Evolution of Ice Cream
    Mo, Jingyi
    Guo, Enyu
    McCartney, D. Graham
    Eastwood, David S.
    Bent, Julian
    Van Dalen, Gerard
    Schuetz, Peter
    Rockett, Peter
    Lee, Peter D.
    MATERIALS, 2018, 11 (10)
  • [3] Fidelity of a Time-Resolved Imaging Diagnostic for Electron Beam Profiles
    Frayer, Daniel
    Ekdahl, Carl A.
    Johnson, Douglas
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2014, 42 (10) : 2594 - 2595
  • [4] TIME-RESOLVED OPTICAL TOMOGRAPHY
    HEBDEN, JC
    WONG, KS
    APPLIED OPTICS, 1993, 32 (04): : 372 - 380
  • [5] Higher order analysis of time-resolved proton radiographs
    Doolan, P. J.
    Bentefour, E. H.
    Testa, M.
    Cascio, E.
    Sharp, G.
    Royle, G.
    Lu, H-M
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (05):
  • [6] Tomographic single-shot time-resolved laser-induced incandescence for soot characterization in turbulent flames
    Mueller, Marcel N.
    Wang, Qian
    Cai, Weiwei
    Huber, Franz J. T.
    Abc, Stefan Will
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2024, 40 (1-4)
  • [7] A genetic approach to limited data tomographic reconstruction of time-resolved energy spectrum of short-pulsed neutron sources
    Turcanu, CO
    Craciunescu, T
    PATTERN RECOGNITION LETTERS, 2002, 23 (08) : 967 - 976
  • [8] Time-resolved TEM beyond fast detectors
    Flannigan, D.
    Chen, J.
    Curtis, W.
    Du, D.
    Engen, P.
    VandenBussche, E.
    Zhang, Y.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2021, 77 : C420 - C420
  • [9] Stirrer design for improving fluidization of cohesive powder: A time-resolved X-ray study
    Wu, Kaiqiao
    Kamphorst, Rens
    Bakker, Anna
    Ford, Jasper
    Wagner, Evert C.
    Ochkin-Koenig, Olga
    Franck, Miika
    Weis, Dominik
    Meesters, Gabrie M. H.
    Ommen, J. Ruud van
    CHEMICAL ENGINEERING SCIENCE, 2024, 294
  • [10] Tomoscopy: Time-Resolved Tomography for Dynamic Processes in Materials
    Garcia-Moreno, Francisco
    Kamm, Paul Hans
    Neu, Tillmann Robert
    Bulk, Felix
    Noack, Mike Andreas
    Wegener, Mareike
    von der Eltz, Nadine
    Schleputz, Christian Matthias
    Stampanoni, Marco
    Banhart, John
    ADVANCED MATERIALS, 2021, 33 (45)