Fabrication and Evaluation of a Bioactive Sr-Ca-P Contained Micro-Arc Oxidation Coating on Magnesium Strontium Alloy for Bone Repair Application

被引:70
作者
Han, Junjie [1 ,2 ]
Wan, Peng [2 ]
Sun, Yu [3 ]
Liu, Zongyuan [2 ]
Fan, Xinmin [1 ]
Tan, Lili [2 ]
Yang, Ke [2 ]
机构
[1] Nanjing Univ Sci & Technol, Dept Mat Sci & Engn, Nanjing 210094, Jiangsu, Peoples R China
[2] Chinese Acad Sci, Inst Met Res, Shenyang 110016, Peoples R China
[3] China Med Univ, Shenyang 110002, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
Magnesium alloy; Strontium; Ca-P coating; Degradation; Micro-arc oxidation; IN-VIVO CORROSION; ANTIFRACTURE EFFICACY; MG ALLOYS; VITRO; HYDROXYAPATITE; BEHAVIOR; RANELATE; BIOMATERIALS; MECHANISM; CALCIUM;
D O I
10.1016/j.jmst.2015.11.012
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Considering the compatibility between degradation and bioactivity of magnesium-based implants for bone repair, micro-arc oxidation is used to modify the magnesium alloy surface in aqueous electrolytes, allowing strontium, calcium, and phosphorus to be incorporated into the coating. The thickness, composition, morphology and phase of this Sr-Ca-P containing coating are characterized by scanning electron microscopy equipped with energy dispersive X-ray spectrometer and X-ray diffraction. The in vitro and in vivo degradation of the coating is evaluated by immersion test, electrochemical test and implantation test. Moreover, the cytocompatibility is tested with osteoblast cell according to ISO 10993. The results show that Sr, Ca and P elements are incorporated into the oxide coating, and a refined structure with tiny discharging micro-pores is observed on the surface of the coating. The Sr-Ca-P coating possesses a better corrosion resistance in vitro and retards the degradation in vivo. Such coating is expected to have significant medical applications on orthopedic implants and bone repair materials. Copyright (C) 2015, The editorial office of Journal of Materials Science & Technology. Published by Elsevier Limited. All rights reserved.
引用
收藏
页码:233 / 244
页数:12
相关论文
共 52 条
  • [41] Effect of microplasma modes and electrolyte composition on micro-arc oxidation coatings on titanium for medical applications
    Terleeva, O. P.
    Sharkeev, Yu P.
    Slonova, A. I.
    Mironov, I. V.
    Legostaeva, E. V.
    Khlusov, I. A.
    Matykina, E.
    Skeldon, P.
    Thompson, G. E.
    [J]. SURFACE & COATINGS TECHNOLOGY, 2010, 205 (06) : 1723 - 1729
  • [42] Vormann Juergen, 2003, Molecular Aspects of Medicine, V24, P27, DOI 10.1016/S0098-2997(02)00089-4
  • [43] Influence of albumin and inorganic ions on electrochemical corrosion behavior of plasma electrolytic oxidation coated magnesium for surgical implants
    Wan, Peng
    Lin, Xiao
    Tan, LiLi
    Li, Lugee
    Li, WeiRong
    Yang, Ke
    [J]. APPLIED SURFACE SCIENCE, 2013, 282 : 186 - 194
  • [44] APPLICATION OF HIGH RESOLUTION TRANSMISSION X-RAY TOMOGRAPHY IN MATERIAL SCIENCE
    Wang Shaogang
    Wang Sucheng
    Zhang Lei
    [J]. ACTA METALLURGICA SINICA, 2013, 49 (08) : 897 - 910
  • [45] (D)egradation and biological properties of Ca-P contained micro-arc oxidation self-sealing coating on pure magnesium for bone fixation
    Wang, Weidan
    Wan, Peng
    Liu, Chen
    Tan, Lili
    Li, Weirong
    Li, Lugee
    Yang, Ke
    [J]. REGENERATIVE BIOMATERIALS, 2015, 2 (02) : 107 - 118
  • [46] Characteristic and in vitro bioactivity of a microarc-oxidized TiO2-based coating after chemical treatment
    Wei, Daqing
    Zhou, Yu
    Jia, Dechang
    Wang, Yaming
    [J]. ACTA BIOMATERIALIA, 2007, 3 (05) : 817 - 827
  • [47] Biodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: short term results of the first prospective, randomized, controlled clinical pilot study
    Windhagen, Henning
    Radtke, Kerstin
    Weizbauer, Andreas
    Diekmann, Julia
    Noll, Yvonne
    Kreimeyer, Ulrike
    Schavan, Robert
    Stukenborg-Colsman, Christina
    Waizy, Hazibullah
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2013, 12
  • [48] In vivo corrosion of four magnesium alloys and the associated bone response
    Witte, F
    Kaese, V
    Haferkamp, H
    Switzer, E
    Meyer-Lindenberg, A
    Wirth, CJ
    Windhagen, H
    [J]. BIOMATERIALS, 2005, 26 (17) : 3557 - 3563
  • [49] In vivo corrosion and corrosion protection of magnesium alloy LAE442
    Witte, F.
    Fischer, J.
    Nellesen, J.
    Vogt, C.
    Vogt, J.
    Donath, T.
    Beckmann, F.
    [J]. ACTA BIOMATERIALIA, 2010, 6 (05) : 1792 - 1799
  • [50] The history of biodegradable magnesium implants: A review
    Witte, Frank
    [J]. ACTA BIOMATERIALIA, 2010, 6 (05) : 1680 - 1692