Magnitude and effects of x-ray scatter in a 256-slice CT scanner

被引:61
作者
Endo, Masahiro [1 ]
Mori, Shinichiro
Tsunoo, Takanori
Miyazaki, Hiroaki
机构
[1] Natl Inst Radiol Sci, Chiba 2638555, Japan
[2] Toshiba Med Syst, Otawara 3248550, Japan
关键词
cone-beam CT; scatter; quantitative imaging; CT technology; CT image quality;
D O I
10.1118/1.2239366
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We developed a prototype 256-slice CT scanner that employs continuous rotation of a cone-beam with a larger cone angle than conventional multidetector CTs (MDCT) to ensure a wide field of view. However, a larger cone angle may result in image deterioration due to increased x-ray scatter. Scattered radiation causes the detected signals to deviate from the true measurement of primary x-ray intensity and may result in artifacts (e.g., cupping and streak artifacts), quantitative inaccuracy in reconstructed CT number, and degradation of contrast-to-noise ratio (CNR). To reduce the effects of scatter, the 256-slice scanner incorporates an antiscatter collimator. Here, we estimated the magnitude of x-ray scatter in the prototype 256-slice CT scanner under clinical scan conditions and quantified the effects of this scatter on CT number accuracy, image noise, uniformity, and low contrast detectability. Although most experiments were performed with the antiscatter collimator, we also estimated the magnitude of x-ray scatter without the collimator to evaluate the scatter rejection efficiency of the collimator. The scatter-to-primary energy fluence ratio (SPR) without the collimator increased as cone angle increased, with estimated values of 49.7% for a 138 mm beam width with a phantom of 200 mm diameter, and 78.5% for a 320 mm diameter phantom. Estimated SPR was drastically decreased with the collimator, with an SPR reduction rate (ratio of SPR with and without the collimator) of 12.7% and 16.8% for the 200 and 320 mm diameter phantoms, respectively. The reduction in x-ray scatter by the collimator resulted in a considerable reduction in scatter effects. The measured uniformity was good and was independent of scatter amount. Although scatter still affected CT number accuracy, this could be corrected by rescaling. Further, although the CNR was decreased, in theory at least, the change was so subtle that it had no substantial effect on low-contrast detectability. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:3359 / 3368
页数:10
相关论文
共 23 条
[11]   SCATTER ESTIMATION FOR A DIGITAL RADIOGRAPHIC SYSTEM USING CONVOLUTION FILTERING [J].
LOVE, LA ;
KRUGER, RA .
MEDICAL PHYSICS, 1987, 14 (02) :178-185
[12]   Enlarged longitudinal dose profiles in cone-beam CT and the need for modified dosimetry [J].
Mori, S ;
Endo, M ;
Nishizawa, K ;
Tsunoo, T ;
Aoyama, T ;
Fujiwara, H ;
Murase, K .
MEDICAL PHYSICS, 2005, 32 (04) :1061-1069
[13]   Clinical potentials of the prototype 256-detector row CT-scanner [J].
Mori, S ;
Endo, M ;
Obata, T ;
Murase, K ;
Fujiwara, H ;
Susumu, K ;
Tanada, S .
ACADEMIC RADIOLOGY, 2005, 12 (02) :148-154
[14]   Physical performance evaluation of a 256-slice CT-scanner for four-dimensional imaging [J].
Mori, S ;
Endo, M ;
Tsunoo, T ;
Kandatsu, S ;
Tanada, S ;
Aradate, H ;
Saito, Y ;
Miyazaki, H ;
Satoh, K ;
Matsushita, S ;
Kusakabe, M .
MEDICAL PHYSICS, 2004, 31 (06) :1348-1356
[15]   GRIDS OR AIR GAPS FOR SCATTER REDUCTION IN DIGITAL RADIOGRAPHY - A MODEL CALCULATION [J].
NEITZEL, U .
MEDICAL PHYSICS, 1992, 19 (02) :475-481
[16]   X-ray scatter correction algorithm for cone beam CT imaging [J].
Ning, R ;
Tang, XY ;
Conover, D .
MEDICAL PHYSICS, 2004, 31 (05) :1195-1202
[17]   X-RAY SCATTER REMOVAL BY DECONVOLUTION [J].
SEIBERT, JA ;
BOONE, JM .
MEDICAL PHYSICS, 1988, 15 (04) :567-575
[18]   A simple, direct method for X-ray scatter estimation and correction in digital radiography and cone-beam CT [J].
Siewerdsen, JH ;
Daly, MJ ;
Bakhtiar, B ;
Moseley, DJ ;
Richard, S ;
Keller, H ;
Jaffray, DA .
MEDICAL PHYSICS, 2006, 33 (01) :187-197
[19]   The influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors [J].
Siewerdsen, JH ;
Moseley, DJ ;
Bakhtiar, B ;
Richard, S ;
Jaffray, DA .
MEDICAL PHYSICS, 2004, 31 (12) :3506-3520
[20]   Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography) [J].
Siewerdsen, JH ;
Jaffray, DA .
MEDICAL PHYSICS, 2000, 27 (08) :1903-1914