A highly reproducible solenoid micropump system for the analysis of total inorganic carbon and ammonium using gas-diffusion with conductimetric detection

被引:29
作者
Henriquez, Camelia [1 ]
Horstkotte, Burkhard [1 ,2 ]
Cerda, Victor [1 ]
机构
[1] Univ Balearic Isl, Analyt Environm Chem Lab, Palma De Mallorca 07122, Spain
[2] Charles Univ Prague, Dept Analyt Chem, Fac Pharm, CZ-50005 Hradec Kralove, Czech Republic
关键词
Multipumping flow system; Solenoid micropumps; Gas difussion; Total inorganic carbon; Ammonium; Conductimetric detection; FLOW-INJECTION ANALYSIS; IN-SITU; UNIT; CELL;
D O I
10.1016/j.talanta.2013.10.005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a simple, economic, and miniaturized flow-based analyzer based on solenoid micropumps is presented. It was applied to determine two parameters of high environmental interest: ammonium and total inorganic carbon (TIC) in natural waters. The method is based on gas diffusion (GD) of CO2 and NH3 through a hydrophobic gas permeable membrane from an acidic or alkaline donor stream, respectively. The analytes are trapped in an acceptor solution, being slightly alkaline for CO2 and slightly acidic for NH3. The analytes are quantified using a homemade stainless steel conductimetric cell. The proposed system required five solenoid micro-pumps, one for each reagent and sample. Two especially made air bubble traps were placed down-stream of the solendoid pumps, which provided the acceptor solutions, by this increasing the method's reproducibility. Values of RSD lower than 1% were obtained. Achieved limits of detection were 0.27 mu mol L-1 for NH4+ and 50 gmol L-1 for TIC. Add-recovery tests were used to prove the trueness of the method and recoveries of 99.5 +/- 7.5% were obtained for both analytes. The proposed system proved to be adequate for monitoring purpose of TIC and NH4+ due to its high sample throughput and repeatability. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:186 / 194
页数:9
相关论文
共 30 条
[1]   Measuring the CO2 flux at the air/water interface in lakes using flow injection analysis [J].
Almeida, FV ;
Guimarares, JR ;
Jardim, WF .
JOURNAL OF ENVIRONMENTAL MONITORING, 2001, 3 (03) :317-321
[2]   A membraneless gas-diffusion unit - multisyringe flow injection spectrophotometric method for ammonium determination in untreated environmental samples [J].
Almeida, M. Ines G. S. ;
Manuel Estela, Jose ;
Segundo, Marcela A. ;
Cerda, Victor .
TALANTA, 2011, 84 (05) :1244-1252
[3]   Trace Levels Determination of Ammonium by Flow Injection Analysis Using Gas-Diffusion and Capacitively Coupled Contactless Conductivity Detection [J].
Braz, Henrique L. ;
Ito, Debora T. ;
Fracassi da Silva, Jose A. ;
do Lago, Claudimir L. ;
Pedrotti, Jairo J. .
ELECTROANALYSIS, 2011, 23 (11) :2594-2600
[4]  
Capone DG, 2008, NITROGEN IN THE MARINE ENVIRONMENT, 2ND EDITION, P1, DOI 10.1057/9780230226203.3567
[5]   Flow techniques in water analysis [J].
Cerdà, V ;
Estela, JM ;
Forteza, R ;
Cladera, A ;
Becerra, E ;
Altimira, P ;
Sitjar, P .
TALANTA, 1999, 50 (04) :695-705
[6]  
Dickson A. G., 1994, Handbook of methods for the analysis of the various parameters of the carbon dioxide system in sea water
[7]  
Elsholz O., 2008, GIT LABOR FACHZEITSC, V2, P110
[8]  
Franson M.A.H., 1992, METODOS NORMALIZADOS
[9]  
Henriquez C., 2012, INT J ENVIRON AN CH, P1
[10]   A contactless conductivity detection cell for flow injection analysis:: Determination of total inorganic carbon [J].
Hohercáková, Z ;
Opekar, F .
ANALYTICA CHIMICA ACTA, 2005, 551 (1-2) :132-136