From static to dynamic 1.5T MRI-linac prototype: impact of gantry position related magnetic field variation on image fidelity

被引:14
作者
Crijns, Sjoerd [1 ]
Raaymakers, Bas [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiotherapy, NL-3584 CX Utrecht, Netherlands
关键词
MRI-guided radiotherapy; MRI-linac; magnetic field inhomogeneity;
D O I
10.1088/0031-9155/59/13/3241
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recently, the MRI-linac prototype at UMC Utrecht was upgraded with a ring-based gantry, where all linac components are mounted on a ring around the MR scanner. Although adaptations have been made to both linac and MR magnets in order to account for mutual magnetic interference, interference problems cannot be ruled out completely. Therefore, in this paper the impact of gantry position dependent magnetic field inhomogeneity variation on the geometrical accuracy of acquired MR images is quantified. Magnetic field maps were acquired in a large field of view for static gantry positions in shimmed and un-shimmed conditions. Reproducibility of the shim settings was assessed. From the fieldmaps, a minimum gradient strength needed to acquire images with geometric distortions of, at most, 1 mm was derived. Moreover, imaging during gantry rotation was performed for a range of imaging parameters and rotation speeds. From the measurements we conclude that images with good geometric fidelity can be obtained for all static gantry positions, provided that shimming is performed for each new gantry position. This indicates that the present prototype is suitable for static IMRT scenarios. Shim settings are highly reproducible, suggesting that shimming via look-up tables is feasible. Finally, imaging during gantry rotation may produce severely distorted images at present and is likely to require advanced compensation methods such as dynamic shimming or higher order reconstruction.
引用
收藏
页码:3241 / 3247
页数:7
相关论文
共 9 条
  • [1] [Anonymous], RADIOTHER ONCOL S1
  • [2] Spatiotemporal magnetic field monitoring for MR
    Barmet, Christoph
    De Zanche, Nicola
    Pruessmann, Klaas P.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (01) : 187 - 197
  • [3] Dynamic shim updating: A new approach towards optimized whole brain shimming
    Blamire, AM
    Rothman, DL
    Nixon, T
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (01) : 159 - 165
  • [4] Real-time correction of magnetic field inhomogeneity-induced image distortions for MRI-guided conventional and proton radiotherapy
    Crijns, S. P. M.
    Raaymakers, B. W.
    Lagendijk, J. J. W.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (01) : 289 - 297
  • [5] A device for realtime 3D image-guided IMRT
    Dempsey, JF
    Benoit, D
    Fitzsimmons, JR
    Haghighat, A
    Li, JG
    Low, DA
    Mutic, S
    Palta, JR
    Romeijn, HE
    Sjoden, GE
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S202 - S202
  • [6] First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system
    Fallone, B. G.
    Murray, B.
    Rathee, S.
    Stanescu, T.
    Steciw, S.
    Vidakovic, S.
    Blosser, E.
    Tymofichuk, D.
    [J]. MEDICAL PHYSICS, 2009, 36 (06) : 2084 - 2088
  • [7] Fast, automated, N-dimensional phase-unwrapping algorithm
    Jenkinson, M
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) : 193 - 197
  • [8] Integrating a 1.5 T MRI scanner with a 6 MV accelerator: proof of concept
    Raaymakers, B. W.
    Lagendijk, J. J. W.
    Overweg, J.
    Kok, J. G. M.
    Raaijmakers, A. J. E.
    Kerkhof, E. M.
    van der Put, R. W.
    Meijsing, I.
    Crijns, S. P. M.
    Benedosso, F.
    van Vulpen, M.
    de Graaff, C. H. W.
    Allen, J.
    Brown, K. J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (12) : N229 - N237
  • [9] Higher Order Reconstruction for MRI in the Presence of Spatiotemporal Field Perturbations
    Wilm, Bertram J.
    Barmet, Christoph
    Pavan, Matteo
    Pruessmann, Klaas P.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (06) : 1690 - 1701