Fetal blood flow velocimetry by phase-contrast MRI using a new triggering method and comparison with Doppler ultrasound in a sheep model: a pilot study

被引:19
作者
Schoennagel, Bjoern P. [1 ]
Remus, Chressen C. [1 ]
Yamamura, Jin [1 ]
Kording, Fabian [1 ]
de Sousa, Manuela Tavares [2 ]
Hecher, Kurt [2 ]
Fischer, Roland [3 ,4 ]
Ueberle, Friedrich [5 ]
Boehme, Matthias [1 ]
Adam, Gerhard [1 ]
Kooijman, Hendrik [6 ]
Wedegaertner, Ulrike [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Diagnost & Intervent Radiol, D-20246 Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Obstet & Fetal Med, D-20246 Hamburg, Germany
[3] Univ Med Ctr Hamburg Eppendorf, Dept Pediat Hematol & Oncol, D-20246 Hamburg, Germany
[4] Childrens Hosp & Res Ctr Oakland, Oakland, CA USA
[5] Hamburg Univ Appl Sci, Hamburg, Germany
[6] Philips Med Syst, Hamburg, Germany
关键词
Magnetic resonance imaging; Cardiac triggering; Fetal blood flow; Flow velocimetry; Fetal sheep; INTRAUTERINE GROWTH RESTRICTION; PRENATAL-DIAGNOSIS; DESCENDING AORTA; VENOUS DOPPLER; ANIMAL-MODEL; VELOCITY; VALIDATION; ARTERY; QUANTIFICATION; CIRCULATION;
D O I
10.1007/s10334-013-0397-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We present the first study demonstrating the feasibility of antenatal blood flow velocimetry performing ECG triggered phase-contrast (PC)-MRI in the fetal aorta by using a newly developed Doppler ultrasound trigger. Five pregnant sheep carrying singleton fetuses (gestational age 121 days) were anesthetized to undergo fetal 2D PC-MRI in the fetal descending aorta (1.5 T) using a newly developed MR-compatible Doppler ultrasound trigger for fetal cardiac triggering. Inter-operator variability was assessed for PC-MR measurements and reproducibility was tested by repeated scans in one fetus. Inter-modality comparison was performed by Doppler ultrasound velocimetry. Fetal cardiac triggering was possible in all examinations. PC-MR velocimetry revealed a mean inter-operator variability of 3 +/- A 5 %. Average peak systolic flow velocities of 62.5 +/- A 4.4 cm/s were in good agreement with Doppler ultrasound measurements of 62.0 +/- A 9.2 cm/s (p (Lord's U test) a parts per thousand << 0.05). Fetal PC-MR velocimetry was successfully performed using the newly developed MR-compatible Doppler ultrasound trigger for intrauterine fetal cardiac triggering, demonstrating high inter-operator and inter-modality agreement. This new method has the high potential for alternative assessment of hemodynamic decompensation of the fetal circulation.
引用
收藏
页码:237 / 244
页数:8
相关论文
共 37 条
[1]  
AKBARI HRG, 2003, CARDIOVASCULAR MRI M, P51
[2]   Relationship between arterial and venous Doppler and perinatal outcome in fetal growth restriction [J].
Baschat, AA ;
Gembruch, U ;
Reiss, I ;
Gortner, L ;
Weiner, CP ;
Harman, CR .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2000, 16 (05) :407-413
[3]   Phase-Contrast Magnetic Resonance Angiography Measurements of Global Cerebral Blood Flow in the Neonate [J].
Benders, Manon J. N. L. ;
Hendrikse, Jeroen ;
de Vries, Linda S. ;
van Bel, Frank ;
Groenendaal, Floris .
PEDIATRIC RESEARCH, 2011, 69 (06) :544-547
[4]   Magnetic resonance imaging of the fetal lung: a pictorial essay [J].
Cannie, M. ;
Jani, J. ;
De Keyzer, F. ;
Van Kerkhove, F. ;
Meersschaert, J. ;
Lewi, L. ;
Deprest, J. ;
Dymarkowski, S. .
EUROPEAN RADIOLOGY, 2008, 18 (07) :1364-1374
[5]   Quantitative metabolic profiles of 2nd and 3rd trimester human amniotic fluid using 1H HR-MAS spectroscopy [J].
Cohn, Brad R. ;
Joe, Bonnie N. ;
Zhao, Shoujun ;
Kornak, John ;
Zhang, Vickie Y. ;
Iman, Rahwa ;
Kurhanewicz, John ;
Vahidi, Kiarash ;
Yu, Jingwei ;
Caughey, Aaron B. ;
Swanson, Mark G. .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2009, 22 (06) :343-352
[6]  
CONKLIN KA, 1980, OBSTET GYNECOL, V56, P471
[7]   Umbilical artery Doppler velocimetry - An update [J].
Divon, MY ;
Ferber, A .
SEMINARS IN PERINATOLOGY, 2001, 25 (01) :44-47
[8]   Monitoring of fetuses with intrauterine growth restriction: longitudinal changes in ductus venosus and aortic isthmus flow [J].
Figueras, F. ;
Benavides, A. ;
Del Rio, M. ;
Crispi, F. ;
Eixarch, E. ;
Martinez, J. M. ;
Hernandez-Andrade, E. ;
Gratacos, E. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2009, 33 (01) :39-43
[9]   The magnetic resonance imaging-based fetal-pelvic index: A pilot study in the community hospital [J].
Fox, LK ;
Huerta-Enochian, GS ;
Hamlin, JA ;
Katz, VL .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2004, 190 (06) :1679-1685
[10]  
Glenn OA, 2006, AM J NEURORADIOL, V27, P1604