Three-dimensional volumetric measurement of red blood cell motion using digital holographic microscopy

被引:118
作者
Choi, Yong-Seok [1 ]
Lee, Sang-Joon [1 ]
机构
[1] Pohang Univ Sci & Technol, Dept Mech Engn, Ctr Biofluid & Biomimet Res, Pohang 790784, South Korea
关键词
FLOW; TRACKING; HEMATOCRIT;
D O I
10.1364/AO.48.002983
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Measurement of blood flow with high spatial and temporal resolutions in a three-dimensional (3D) volume is a challenge in biomedical research fields. In this study, digital holographic microscopy is used to measure the 3D motion of human red blood cells (RBCs) in a microscale volume. The cinematographic holography technique, which uses a high-speed camera, enabled the continuous tracking of individual RBCs in a microtube flow. Several autofocus functions that quantify the sharpness of reconstructed RBC images are evaluated to locate the accurate depthwise position of RBCs. In this study, the squared Laplacian function yields the smallest depth of focus and locates the depthwise positions of RBCs with a root mean square error of 2.3 mu m. By applying this method, we demonstrate the measurement of four-dimensional (space and time) trajectories as well as 3D velocity profiles of RBCs. The measurement uncertainties of the present method are also discussed. (C) 2009 Optical Society of America
引用
收藏
页码:2983 / 2990
页数:8
相关论文
共 20 条
[1]   A new two-frame particle tracking algorithm using match probability [J].
Baek, SJ ;
Lee, SJ .
EXPERIMENTS IN FLUIDS, 1996, 22 (01) :23-32
[2]  
Goodman J., 1996, Opt. Eng
[3]   A COMPARISON OF DIFFERENT FOCUS FUNCTIONS FOR USE IN AUTOFOCUS ALGORITHMS [J].
GROEN, FCA ;
YOUNG, IT ;
LIGTHART, G .
CYTOMETRY, 1985, 6 (02) :81-91
[4]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[5]   In vitro hemorheological study on the hematocrit effect of human blood flow in a microtube [J].
Ji, Ho Seong ;
Lee, Sang Joon .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2008, 40 (01) :19-30
[6]   Measurement of 3D laminar flow inside a micro tube using micro digital holographic particle tracking velocimetry [J].
Kim, Seok ;
Lee, Sang Joon .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2007, 17 (10) :2157-2162
[7]   Autofocusing in digital holographic phase contrast microscopy on pure phase objects for live cell imaging [J].
Langehanenberg, Patrik ;
Kemper, Bjoern ;
Dirksen, Dieter ;
von Bally, Gert .
APPLIED OPTICS, 2008, 47 (19) :D176-D182
[8]   In vitro confocal micro-PIV measurements of blood flow in a square microchannel: The effect of the haematocrit on instantaneous velocity profiles [J].
Lima, Rui ;
Wada, Shigeo ;
Takeda, Motohiro ;
Tsubota, Ken-ichi ;
Yamaguchi, Takami .
JOURNAL OF BIOMECHANICS, 2007, 40 (12) :2752-2757
[9]   Holographic particle image velocimetry: from film to digital recording [J].
Meng, H ;
Pan, G ;
Pu, Y ;
Woodward, SH .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (04) :673-685
[10]   Computational reconstruction of images from holograms [J].
Milgram, JH ;
Li, WC .
APPLIED OPTICS, 2002, 41 (05) :853-864