Impact of Uniform Methods on Interlaboratory Antibody Titration Variability Antibody Titration and Uniform Methods

被引:34
作者
Bachegowda, Lohith S. [1 ]
Cheng, Yan H. [1 ]
Long, Thomas [2 ]
Shaz, Beth H. [1 ]
机构
[1] New York Blood Ctr, Dept Transfus Med, New York, NY 10021 USA
[2] Coll Amer Pathologists, Biostat, Northfield, IL USA
关键词
INCOMPATIBLE-TRANSPLANTATION-COMMITTEE; PERINATAL IMMUNOHEMATOLOGY; B ANTIBODIES; ABO; GEL; GUIDELINES; TITERS; ASSAY; TUBE;
D O I
10.5858/arpa.2015-0351-OA
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Context.-Substantial variability between different antibody titration methods prompted development and introduction of uniform methods in 2008. Objective.-To determine whether uniform methods consistently decrease interlaboratory variation in proficiency testing. Design.-Proficiency testing data for antibody titration between 2009 and 2013 were obtained from the College of American Pathologists. Each laboratory was supplied plasma and red cells to determine anti-A and anti-D antibody titers by their standard method: gel or tube by uniform or other methods at different testing phases (immediate spin and/or room temperature [anti-A], and/or anti-human globulin [AHG: anti-A and anti-D]) with different additives. Interlaboratory variations were compared by analyzing the distribution of titer results by method and phase. Results.-A median of 574 and 1100 responses were reported for anti-A and anti-D antibody titers, respectively, during a 5-year period. The 3 most frequent (median) methods performed for anti-A antibody were uniform tube room temperature (147.5; range, 119-159), uniform tube AHG (143.5; range, 134-150), and other tube AHG (97; range, 82-116); for anti-D antibody, the methods were other tube (451; range, 431-465), uniform tube (404; range, 382-462), and uniform gel (137; range, 121-153). Of the larger reported methods, uniform gel AHG phase for anti-A and anti-D antibodies had the most participants with the same result (mode). For anti-A antibody, 0 of 8 (uniform versus other tube room temperature) and 1 of 8 (uniform versus other tube AHG), and for anti-D antibody, 0 of 8 (uniform versus other tube) and 0 of 8 (uniform versus other gel) proficiency tests showed significant titer variability reduction. Conclusion.-Uniform methods harmonize laboratory techniques but rarely reduce interlaboratory titer variance in comparison with other methods.
引用
收藏
页码:131 / 138
页数:8
相关论文
共 30 条
[11]  
HAVEMANN H, 1992, CANCER, V69, P252, DOI 10.1002/1097-0142(19920101)69:1<252::AID-CNCR2820690141>3.0.CO
[12]  
2-4
[13]   Comparison of antibody titers in donor specimens and associated AS-1 leukoreduced donor units [J].
Hill, Elizabeth A. ;
Bryant, Barbara J. .
TRANSFUSION, 2014, 54 (06) :1580-1584
[14]   PRENATAL AND PERINATAL IMMUNOHEMATOLOGY - RECOMMENDATIONS FOR SEROLOGIC MANAGEMENT OF THE FETUS, NEWBORN-INFANT, AND OBSTETRIC PATIENT [J].
JUDD, WJ ;
LUBAN, NLC ;
NESS, PM ;
SILBERSTEIN, LE ;
STROUP, M ;
WIDMANN, FK .
TRANSFUSION, 1990, 30 (02) :175-183
[15]   Practice guidelines for prenatal and perinatal immunohematology, revisited [J].
Judd, WJ .
TRANSFUSION, 2001, 41 (11) :1445-1452
[16]   Comparison of ABO Antibody Titers on the Basis of the Antibody Detection Method Used [J].
Kang, Seon Joo ;
Lim, Young Ae ;
Baik, Sae Yun .
ANNALS OF LABORATORY MEDICINE, 2014, 34 (04) :300-306
[17]   Rapid quantitation of immunoglobulin G antibodies specific for blood group antigens A and B by surface plasmon resonance [J].
Kimura, S ;
Yurugi, K ;
Segawa, H ;
Kuroda, J ;
Sato, K ;
Nogawa, M ;
Yuasa, T ;
Egawa, H ;
Tanaka, K ;
Maekawa, T .
TRANSFUSION, 2005, 45 (01) :56-62
[18]   A series of surveys on assay for anti-A/B antibody by Japanese ABO-incompatible Transplantation Committee [J].
Kobayashi, T ;
Saito, K .
XENOTRANSPLANTATION, 2006, 13 (02) :136-140
[19]   Comparing the tube and gel techniques for ABO antibody titration, as performed in three European centers [J].
Kumlien, Gunilla ;
Wilpert, Jochen ;
Safwenberg, Jan ;
Tyden, Gunnar .
TRANSPLANTATION, 2007, 84 (12) :S17-S19
[20]   THE GEL TEST - A NEW WAY TO DETECT RED-CELL ANTIGEN-ANTIBODY REACTIONS [J].
LAPIERRE, Y ;
RIGAL, D ;
ADAM, J ;
JOSEF, D ;
MEYER, F ;
GREBER, S ;
DROT, C .
TRANSFUSION, 1990, 30 (02) :109-113