Assessment of anterior and posterior corneal indices using two Scheimpflug analyzers

被引:6
|
作者
Fahd, Daoud Charbel [1 ]
Cherfan, Carole George [1 ]
Raad, Claudia [2 ]
Asouad, Marc [2 ]
Awwad, Shady Tanus [1 ]
机构
[1] Amer Univ Beirut, Med Ctr, Dept Ophthalmol, Beirut, Lebanon
[2] LaserVision Inc, Beirut, Lebanon
关键词
Cornea/pathology; Cornea/anatomy & histology; Corneal topography; Corneal pachymetry; Photography/instrumentation; THICKNESS MEASUREMENTS; REPEATABILITY; PENTACAM; ORBSCAN; ULTRASOUND; GALILEI;
D O I
10.5935/0004-2749.20140006
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the agreement between the elevation and curvature measurements of the anterior and posterior corneal surfaces obtained using the Galilei Dual Scheimpflug Analyzer and those obtained using the Pentacam single Scheimpflug system. Methods: This prospective, noninterventional, diagnostic study was conducted at the Department of Ophthalmology at the American University of Beirut (Medical Center) and included 60 eyes of 60 consecutive patients. Measurements were obtained using 2 different Scheimpflug analyzers (Galilei and Pentacam). The best-fit sphere was set at 8 mm in both machines. Pachymetry (CCT), anterior elevation (AE) and posterior elevation (PE), and curvature were assessed. Pearson's correlation coefficients, comparison of means, and Bland-Altman plots were used to evaluate agreement between the 2 systems. Results: The average CCT (at the corneal apex) was 533 +/- 35 mu m and 532 +/- 37 mu m (p=0.980), the average central AE was 1.25 +/- 3.95 mu m and 2.29 +/- 5.28 mu m (p=0.964), and the average central PE was 4.19 +/- 8.18 mu m and 5.42 +/- 14.05 (p=0.956) mu m with the Galilei and Pentacam, respectively. Conclusion: The Scheimpflug analyzers correlated well in the assessment of pachymetry, elevation, and curvature.
引用
收藏
页码:17 / 20
页数:4
相关论文
共 50 条
  • [1] Repeatability, Reproducibility, and Agreement of Two Scheimpflug-Placido Anterior Corneal Analyzers for Posterior Corneal Surface Measurement
    Bao, Fangjun
    Savini, Giacomo
    Shu, Bao
    Zhu, Senmiao
    Gao, Rongrong
    Dang, Guanxin
    Yu, Ayong
    Wang, Qinmei
    Huang, Jinhai
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (08) : 524 - U114
  • [2] Comparison of corneal measurements using two different Scheimpflug analyzers in Sirius and Pentacam devices
    Abdi, Parisa
    Atighehchian, Mehrnaz
    Farsiani, Amir Reza
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [3] Comparison of corneal measurements using two different Scheimpflug analyzers in Sirius and Pentacam devices
    Parisa Abdi
    Mehrnaz Atighehchian
    Amir Reza Farsiani
    Scientific Reports, 13
  • [4] Agreement of corneal biomechanics parameters measured with two dynamic Scheimpflug analyzers
    Iskander, D. Robert
    Buslowicz, Karolina
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [5] Measurements of Anterior and Posterior Corneal Curvatures with OCT and Scheimpflug Biometers in Patients with Low Total Corneal Astigmatism
    Muzyka-Wozniak, Maria
    Oleszko, Adam
    Grzybowski, Andrzej
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (23)
  • [6] Scheimpflug Camera Measurement of Anterior and Posterior Corneal Curvature in Eyes With Previous Radial Keratotomy
    Camellin, Massimo
    Savini, Giacomo
    Hoffer, Kenneth J.
    Carbonelli, Michele
    Barboni, Piero
    JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (04) : 275 - 279
  • [7] Repeatability and agreement of 2 Scheimpflug analyzers in measuring the central corneal thickness and anterior chamber angle, volume, and depth
    Bedei, Andrea
    Appolloni, Ilaria
    Madesani, Antonio
    Pietrelli, Alessia
    Franceschi, Sara
    Barabesi, Lucio
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 : S29 - S32
  • [8] Assessment of corneal biomechanics in anisometropia using Scheimpflug technology
    Gao, Rongrong
    Ren, Yuecheng
    Li, Siheng
    Xu, Huilin
    Lin, Xuanqiao
    McAlinden, Colm
    Ye, Junming
    Huang, Jinhai
    Yu, Jinjin
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [9] Scheimpflug imaged corneal changes on anterior and posterior surfaces after collagen cross-linking
    Hassan, Ziad
    Modis, Laszlo
    Szalai, Eszter
    Berta, Andras
    Nemeth, Gabor
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2014, 7 (02) : 313 - 316
  • [10] Scheimpflug imaged corneal changes on anterior and posterior surfaces after collagen cross-linking
    Ziad Hassan
    Laszlo Modis
    Eszter Szalai
    Andras Berta
    Gabor Nemeth
    International Journal of Ophthalmology, 2014, (02) : 313 - 316