Instrumentation optimization for Positron Emission Mammography

被引:20
作者
Moses, WW [1 ]
Qi, JY [1 ]
机构
[1] Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
关键词
Positron Emission Mammography; breast cancer; PEM camera design and optimization; Fisher information matrix;
D O I
10.1016/j.nima.2004.03.066
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The past several years have seen designs for PET cameras optimized to image the breast, commonly known as Positron Emission Mammography (PEM) cameras. The guiding principal behind PEM instrumentation is that a camera whose field of view is restricted to a single breast has higher performance and lower cost than a conventional PET camera. The most common geometry is a pair of parallel planes of detector modules, although geometries that encircle the breast have also been proposed. The ability of the detectors to measure the depth of interaction (DOI) is also a relevant feature. This paper finds that while both the additional solid angle coverage afforded by encircling the breast and the decreased blurring afforded by the DOI measurement improve performance, for small lesions the ability to measure DOI is more important than the ability to encircle the breast. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:76 / 82
页数:7
相关论文
共 13 条
  • [1] Avril N, 2001, J NUCL MED, V42, P9
  • [2] OBJECTIVE ASSESSMENT OF IMAGE QUALITY .2. FISHER INFORMATION, FOURIER CROSSTALK, AND FIGURES OF MERIT FOR TASK-PERFORMANCE
    BARRETT, HH
    DENNY, JL
    WAGNER, RF
    MYERS, KJ
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (05): : 834 - 852
  • [3] Design and evaluation of an LSO PET detector for breast cancer imaging
    Doshi, NK
    Shao, YP
    Silverman, RW
    Cherry, SR
    [J]. MEDICAL PHYSICS, 2000, 27 (07) : 1535 - 1543
  • [4] Dedicated PET scanners for breast imaging
    Freifelder, R
    Karp, JS
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (12) : 2463 - 2480
  • [5] CERIUM-DOPED LUTETIUM OXYORTHOSILICATE - A FAST, EFFICIENT NEW SCINTILLATOR
    MELCHER, CL
    SCHWEITZER, JS
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) : 502 - 505
  • [6] MOSES WW, 1995, J NUCL MED, V36, P69
  • [7] Positron emission mammographic instrument: Initial results
    Murthy, K
    Aznar, M
    Bergman, AM
    Thompson, CJ
    Robar, JL
    Lisbona, R
    Loutfi, A
    Gagnon, JH
    [J]. RADIOLOGY, 2000, 215 (01) : 280 - 285
  • [8] Comparison of rectangular and dual-planar positron emission mammography scanners
    Qi, JY
    Kuo, C
    Huesman, RH
    Klein, GJ
    Moses, WW
    Reutter, BW
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2089 - 2096
  • [9] The potential role of positron emission mammography for detection of breast cancer. A phantom study
    Raylman, RR
    Majewski, S
    Wojcik, R
    Weisenberger, AG
    Kross, B
    Popov, V
    Bishop, HA
    [J]. MEDICAL PHYSICS, 2000, 27 (08) : 1943 - 1954
  • [10] THOMPSON CJ, 1995, IEEE MED IM C, P1074