Simulation of single fiber pullout response with account of fiber morphology

被引:29
作者
Ellis, B. D. [1 ]
McDowell, D. L. [1 ,2 ]
Zhou, M. [1 ,2 ]
机构
[1] Georgia Inst Technol, Woodruff Sch Mech Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Sch Mat Sci & Engn, Atlanta, GA 30332 USA
关键词
Cementitious composites; Fiber morphology; Finite element analysis; Twisted fibers; STEEL; BEHAVIOR; PERFORMANCE; CONCRETE;
D O I
10.1016/j.cemconcomp.2014.01.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A finite element model was developed at the single fiber length scale to predict the quasi-static pullout response of individual fibers from cementitious composites. The model accounts for energy dissipation through granular flow of the interfacial transition zone (ITZ) and matrix, plastic work in the fiber, and frictional dissipation at the fiber-ITZ interface. The considered fiber morphology was a triangular cross section that had been uniformly twisted along the fiber length. The model was calibrated to published experimental data for fiber pitches of 12.7 and 38.1 mm/revolution pulled from cement mortar with a 44-MPa unconfined compressive strength. The model was used to investigate slip-hardening behavior, tunneling of the cement mortar, in situ pullout behavior of helically twisted fibers at a crack plane, and provide an alternate explanation for the pullout response of twisted fibers from a 84-MPa unconfined compressive strength matrix containing silica fume. Calculations show that twisted fibers can provide up to 5 times the peak pullout force and 10 times the total work compared with,straight fibers and infer work-hardening behavior during fiber pullout. The findings indicate that the tailoring of fiber morphology and control of constituent properties are important avenues for achieving significant improvements in the performance of fiber-reinforced cementitious composites. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:42 / 52
页数:11
相关论文
共 32 条
[1]  
Alwan JM., 1999, Concr. Sci. Eng, V1, P15
[2]  
American Society of Testing and Materials C1609, 2012, STANDARD TEST METHOD, DOI [10.1520/C1609_C1609M-12, DOI 10.1520/C1609_C1609M-12]
[3]  
[Anonymous], 2008, BUILDING CODE REQUIR
[4]  
[Anonymous], 2010, AB V6 10 THEOR MAN
[5]  
[Anonymous], HERON
[6]  
ASTM, 2007, STAND SPEC STEEL WIR
[7]   COEFFICIENT OF FRICTION FOR STEEL ON CONCRETE AT HIGH NORMAL STRESS [J].
Baltay, Peter ;
Gjelsvik, Atle .
JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 1990, 2 (01) :46-49
[8]   Characterising the time-dependant behaviour on the single fibre level of SHCC: Part 2: The rate effects on fibre pull-out tests [J].
Boshoff, William P. ;
Mechtcherine, Viktor ;
van Zijl, Gideon P. A. G. .
CEMENT AND CONCRETE RESEARCH, 2009, 39 (09) :787-797
[9]  
CEB, 1991, CEB FIP MOD COD 1990
[10]  
Chakrabarty J., 2006, Theory of Plasticity