摘要
A sensitive and simple flow-injection chemiluminescence (FI-CL) method, which was based on the CL intensity generated from the redoxreaction of potassium permanganate (KMnO4)-formaldehyde in vitriol (H2SO4) medium, has been developed, validated and applied for the determination of naphazoline hydrochloride and oxymetazoline hydrochloride. Besides oxidants and sensitizers, the effect of the concentration of H2SO4, KMnO4, and formaldehyde was investigated. Under the optimum conditions, the linear range was 1.0 x 10(-2)-7.0 mg/L for naphazoline hydrochloride and 5.0 x 10(-2)-10.0 mg/L for oxymetazoline hydrochloride. During seven repeated inter-day and intra-day precision tests of 0.1, 1.0 and 10.0 mg/L samples, the relative standard deviations all corresponded to reference values. The detection limit was 8.69 x 10(-3) mg/L for naphazoline hydrochloride and 3.47 x 10(-2) mg/L for oxymetazoline hydrochloride (signal-to-noise ratio <= 3). This method has been successfully implemented for the determination of naphazoline hydrochloride and oxymetazoline hydrochloride in pharmaceuticals. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:178 / 182
页数:5
相关论文
共 50 条
  • [21] Determination of promethazine hydrochloride by flow injection analysis with chemiluminescence detection
    Xue, YY
    He, YH
    Feng, ML
    Lu, JR
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 27 (04) : 427 - 429
  • [22] Determination of phenylephrine hydrochloride by flow injection analysis with chemiluminescence detection
    Mestre, YF
    Zamora, LL
    Calatayud, JM
    JOURNAL OF AOAC INTERNATIONAL, 2001, 84 (01) : 13 - 18
  • [23] Determination of procaine hydrochloride using flow injection inhibitory chemiluminescence
    Li, NB
    Chi, YW
    Wang, J
    Duan, JP
    Chen, GN
    LUMINESCENCE, 2003, 18 (03) : 125 - 130
  • [24] FLOW-INJECTION TURBIDIMETRIC DETERMINATION OF FLUOXETINE HYDROCHLORIDE IN PHARMACEUTICAL FORMULATIONS
    Suarez, Willian Toito
    Sartori, Elen Romao
    Batista, Erica Ferreira
    Fatibello-Filho, Orlando
    QUIMICA NOVA, 2009, 32 (09): : 2396 - 2400
  • [25] Flow injection analysis of oxymetazoline hydrochloride with inhibited chemiluminescent detection
    García-Campaña, AM
    Sendra, JMB
    Vargas, MPB
    Baeyens, WRG
    Zhang, XR
    ANALYTICA CHIMICA ACTA, 2004, 516 (1-2) : 245 - 249
  • [26] Determination of ascorbic acid by flow-injection chemiluminescence method
    Yu, J.
    Zhang, C.
    Tan, Y.
    Ge, S.
    Dai, P.
    Zha, Y.
    LUMINESCENCE, 2008, 23 (02) : 107 - 107
  • [27] Flow-injection chemiluminescence method for the determination of hydrocortisone and progesterone
    Li, HN
    Ci, YX
    APPLIED SPECTROSCOPY, 1997, 51 (10) : 1484 - 1487
  • [28] Determination of ofloxacin using a chemiluminescence flow-injection method
    Rao, Y
    Tong, Y
    Zhang, XR
    Luo, G
    Baeyens, WRG
    ANALYTICA CHIMICA ACTA, 2000, 416 (02) : 227 - 230
  • [29] Chemiluminescence determination of ultramicro DNA with a flow-injection method
    Chen, H
    Zhou, M
    Jin, XY
    Song, YM
    Zhang, ZY
    Ma, YJ
    ANALYTICA CHIMICA ACTA, 2003, 478 (01) : 31 - 36
  • [30] SELECTIVE DETERMINATION OF TRIPHOSPHONUCLEOTIDE BY A FLOW-INJECTION CHEMILUMINESCENCE METHOD
    OHNO, Y
    HOBO, T
    TAMURA, R
    ISHII, M
    BUNSEKI KAGAKU, 1993, 42 (03) : 183 - 190