A study on the value of computer-assisted assessment for SPECT/CT-scans in sentinel lymph node diagnostics of penile cancer as well as clinical reliability and morbidity of this procedure

被引:5
作者
Luetzen, Ulf [1 ]
Naumann, Carsten Maik [2 ]
Marx, Marlies [1 ]
Zhao, Yi [1 ]
Jueptner, Michael [1 ]
Baumann, Rene [3 ]
Papp, Laszlo [4 ]
Zsoter, Norbert [5 ]
Aksenov, Alexey [2 ]
Juenemann, Klaus-Peter [2 ]
Zuhayra, Maaz [1 ]
机构
[1] Univ Hosp Schleswig Holstein, Dept Nucl Med Mol Imaging Diagnost & Therapy, Campus Kiel,Feldstr 21,Haus 50, D-24105 Kiel, Germany
[2] Univ Hosp Schleswig Holstein, Dept Urol & Pediat Urol, Campus Kiel, Kiel, Germany
[3] Univ Hosp Schleswig Holstein, Dept Radiotherapy, Campus Kiel, Kiel, Germany
[4] Med Univ Vienna, Div Nucl Med, Vienna, Austria
[5] Mediso Ltd, Budapest, Hungary
关键词
SPECT/CT; Computer-assisted assessment; Penile cancer; Sentinel lymph nodes; Lymph node biopsy; Tc; 99; m-nanocolloid; CAD; SQUAMOUS-CELL CARCINOMA; AIDED DETECTION; BREAST-CANCER; BIOPSY; LYMPHOSCINTIGRAPHY; LOCALIZATION; IMAGES; CAMERA;
D O I
10.1186/s40644-016-0087-z
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Because of the increasing importance of computer-assisted post processing of image data in modern medical diagnostic we studied the value of an algorithm for assessment of single photon emission computed tomography/computed tomography (SPECT/CT)-data, which has been used for the first time for lymph node staging in penile cancer with non-palpable inguinal lymph nodes. In the guidelines of the relevant international expert societies, sentinel lymph node-biopsy (SLNB) is recommended as a diagnostic method of choice. The aim of this study is to evaluate the value of the afore-mentioned algorithm and in the clinical context the reliability and the associated morbidity of this procedure. Methods: Between 2008 and 2015, 25 patients with invasive penile cancer and inconspicuous inguinal lymph node status underwent SLNB after application of the radiotracer Tc-99m labelled nanocolloid. We recorded in a prospective approach the reliability and the complication rate of the procedure. In addition, we evaluated the results of an algorithm for SPECT/CT-data assessment of these patients. Results: SLNB was carried out in 44 groins of 25 patients. In three patients, inguinal lymph node metastases were detected via SLNB. In one patient, bilateral lymph node recurrence of the groins occurred after negative SLNB. There was a false-negative rate of 4 % in relation to the number of patients (1/25), resp. 4.5 % in relation to the number of groins (2/44). Morbidity was 4 % in relation to the number of patients (1/25), resp. 2.3 % in relation to the number of groins (1/44). The results of computer-assisted assessment of SPECT/CT data for sentinel lymph node (SLN)-diagnostics demonstrated high sensitivity of 88.8 % and specificity of 86.7 %. Conclusions: SLNB is a very reliable method, associated with low morbidity. Computer-assisted assessment of SPECT/CT data of the SLN-diagnostics shows high sensitivity and specificity. While it cannot replace the assessment by medical experts, it can still provide substantial supplement and assistance.
引用
收藏
页数:16
相关论文
共 34 条
[1]  
[Anonymous], 2008, 2008 INT S INFORM TE
[2]   Computer-aided detection of colorectal polyps: Can it improve sensitivity of less-experienced readers? Preliminary findings [J].
Baker, Mark E. ;
Bogoni, Luca ;
Obuchowski, Nancy A. ;
Dass, Chandra ;
Kendzierski, Renee M. ;
Remer, Erick M. ;
Einstein, David M. ;
Cathier, Pascal ;
Jerebko, Anna ;
Lakare, Sarang ;
Blum, Andrew ;
Caroline, Dina F. ;
Macari, Michael .
RADIOLOGY, 2007, 245 (01) :140-149
[3]   Sentinel node in breast cancer procedural guidelines [J].
Buscombe, John ;
Paganelli, Giovanni ;
Burak, Zeynep E. ;
Waddington, Wendy ;
Maublant, Jean ;
Prats, Enrique ;
Palmedo, Holger ;
Schillaci, Orazio ;
Maffioli, Lorenzo ;
Lassmann, M. ;
Chiesa, Carlo ;
Bombardieri, Emilio ;
Chiti, Arturo .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (12) :2154-2159
[4]  
Dorn R, 2006, NUKLEARMEDIZINER, V29, P116
[5]   Role of ventilation scintigraphy in diagnosis of acute pulmonary embolism:: an evaluation using artificial neural networks [J].
Evander, E ;
Holst, H ;
Järund, A ;
Ohlsson, M ;
Wollmer, P ;
Åström, K ;
Edenbrandt, L .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (07) :961-965
[6]  
Even-Sapir E, 2003, J NUCL MED, V44, P1413
[7]  
Fuchs J, 2013, UROLOGE, V52, P1447, DOI 10.1007/s00120-013-3166-9
[8]   Nodal Staging in Penile Carcinoma by Dynamic Sentinel Node Biopsy After Previous Therapeutic Primary Tumour Resection [J].
Graafland, Niels M. ;
Olmos, Renato A. Valdes ;
Meinhardt, Willem ;
Bex, Axel ;
van der Poel, Henk G. ;
van Boven, Hester H. ;
Nieweg, Omgo E. ;
Horenblas, Simon .
EUROPEAN UROLOGY, 2010, 58 (05) :748-751
[9]   Automated interpretation of PET/CT images in patients with lung cancer [J].
Gutte, Henrik ;
Jakobsson, David ;
Olofsson, Fredrik ;
Ohlsson, Mattias ;
Valind, Sven ;
Loft, Annika ;
Edenbrandt, Lars ;
Kjaer, Andreas .
NUCLEAR MEDICINE COMMUNICATIONS, 2007, 28 (02) :79-84
[10]  
Hahn S, 2009, AUTOMATISCHE LASIONS