Impingement of metal-polyethylene hip prostheses Potential cause of high systemic titanium levels?

被引:0
|
作者
Lutter, Christoph [1 ]
Kluess, Daniel [1 ]
Enz, Andreas [1 ]
Mittelmeier, Wolfram [1 ]
机构
[1] Univ Med Ctr Rostock, Dept Orthoped, Doberaner Str 142, D-18057 Rostock, Germany
来源
ORTHOPADE | 2020年 / 49卷 / 12期
关键词
Cobalt; Chromium; Nickel; Metal ions; EXERCISE-RELATED RISE; ION LEVELS; ARTHROPLASTY; BLOOD; SERUM; BEARINGS; DEBRIS;
D O I
10.1007/s00132-020-03998-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
High blood metal levels have been described in the past, primarily in metal-on-metal bearings. Other possible causes are often underestimated. This report presents the case of a 70-year-old female patient who suffered from pronounced neurological symptoms (especially fatigue and concentration problems) 13 years after implantation of a hip endoprosthesis with metal-polyethylene (ME-PE) bearing. An osteolysis in the pelvis and loosening of the acetabular component were detected. In addition, large quantities of metallic black discolored granulomas were detected in the periarticular environment during surgery. A ventral impingement with destruction of the titanium cup and the PE insert was identified as the suspected cause of this condition. The postoperative course of the blood metal levels was unexpected as titanium levels increased massively in the blood. Anamnesis, course of the disease and the surgical procedure as well as especially the course of the metal values in the blood of the patient are presented. Possible causes for the excessive occurrence of metal abrasion, the systemic distribution and potential toxic effects of titanium are explained and discussed in detail. In addition, the currently available literature on the subject is critically examined.
引用
收藏
页码:1066 / 1071
页数:6
相关论文
共 50 条
  • [31] Surveillance of Patients with Metal-on-Metal Hip Resurfacing and Total Hip Prostheses A Prospective Cohort Study to Investigate the Relationship Between Blood Metal Ion Levels and Implant Failure
    Hart, A. J.
    Sabah, S. A.
    Sampson, B.
    Skinner, J. A.
    Powell, J. J.
    Palla, L.
    Pajamaki, K. J. J.
    Puolakka, T.
    Reito, A.
    Eskelinen, A.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (13): : 1091 - 1099
  • [32] Metal-on-Metal Hip Joint Prostheses: a Retrospective Case Series Investigating the Association of Systemic Toxicity with Serum Cobalt and Chromium Concentrations
    Ho J.H.
    Leikin J.B.
    Dargan P.I.
    Archer J.R.H.
    Wood D.M.
    Brent J.
    Journal of Medical Toxicology, 2017, 13 (4) : 321 - 328
  • [33] Metal-on-metal hip joint prostheses: a retrospective case series investigating association of systemic toxicity with serum cobalt and chromium concentrations
    Ho, James
    Wax, Paul
    Leikin, Jerrold B.
    Archer, John R. H.
    Wood, David M.
    Dargan, Paul I.
    Brent, Jeffrey
    CLINICAL TOXICOLOGY, 2016, 54 (04) : 430 - 431
  • [34] The validity of serum levels as a surrogate measure of systemic exposure to metal ions in hip replacement
    Daniel, J.
    Ziaee, H.
    Pynsent, P. B.
    McMinn, D. J. W.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (06): : 736 - 741
  • [35] Low-wear effect of high-dose gamma-irradiated crosslinked polyethylene in total hip prostheses
    Oonishi, H
    Clarke, IC
    Good, VD
    Tsuji, E
    Ikada, Y
    Ishimaru, H
    Tateishi, T
    Fujisawa, A
    Masuda, S
    Kumakura, M
    JOINT ARTHROPLASTY, 1999, : 97 - 108
  • [36] Potential presence of metals in patients treated with metal–metal coupling prostheses for hip arthroplasty at 7 and 10 years of follow-up
    Sessa G.
    Testa G.
    Gioitta Iachino S.
    Costarella L.
    Puma Pagliarello C.
    Ferrante M.
    Grasso A.
    Pavone V.
    European Journal of Orthopaedic Surgery & Traumatology, 2018, 28 (4) : 637 - 643
  • [37] Mechanisms of damage to metal-on-polyethylene articulating surfaces of total hip prostheses: influence of intra-articulate migration of metallic debris
    Najjar, D
    Iost, A
    Bigerelle, M
    Coorevits, T
    Girard, J
    Migaud, H
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2004, 90 (08): : 732 - 740
  • [38] Metal serum levels in 48 patients bearing a chromium-cobalt total hip arthroplasty with a metal-on-polyethylene combination
    Damie, F
    Favard, L
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2004, 90 (03): : 241 - 248
  • [39] Serum Metal Levels for Diagnosis of Adverse Local Tissue Reactions Secondary to Corrosion in Metal-on-Polyethylene Total Hip Arthroplasty
    Fillingham, Yale A.
    Della Valle, Craig J.
    Bohl, Daniel D.
    Kelly, Mick P.
    Hall, Deborah J.
    Pourzal, Robin
    Jacobs, Joshua J.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (09): : S272 - S277
  • [40] A Case of Titanium Pseudotumor and Systemic Toxicity After Total Hip Arthroplasty Polyethylene Failure (vol 6, pg 710, 2020)
    Tarpada, Sandip P.
    Loloi, Jeremy
    Schwechter, Evan M.
    ARTHROPLASTY TODAY, 2022, 15 : 238 - 238