Impingement of metal-polyethylene hip prostheses Potential cause of high systemic titanium levels?

被引:0
|
作者
Lutter, Christoph [1 ]
Kluess, Daniel [1 ]
Enz, Andreas [1 ]
Mittelmeier, Wolfram [1 ]
机构
[1] Univ Med Ctr Rostock, Dept Orthoped, Doberaner Str 142, D-18057 Rostock, Germany
来源
ORTHOPADE | 2020年 / 49卷 / 12期
关键词
Cobalt; Chromium; Nickel; Metal ions; EXERCISE-RELATED RISE; ION LEVELS; ARTHROPLASTY; BLOOD; SERUM; BEARINGS; DEBRIS;
D O I
10.1007/s00132-020-03998-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
High blood metal levels have been described in the past, primarily in metal-on-metal bearings. Other possible causes are often underestimated. This report presents the case of a 70-year-old female patient who suffered from pronounced neurological symptoms (especially fatigue and concentration problems) 13 years after implantation of a hip endoprosthesis with metal-polyethylene (ME-PE) bearing. An osteolysis in the pelvis and loosening of the acetabular component were detected. In addition, large quantities of metallic black discolored granulomas were detected in the periarticular environment during surgery. A ventral impingement with destruction of the titanium cup and the PE insert was identified as the suspected cause of this condition. The postoperative course of the blood metal levels was unexpected as titanium levels increased massively in the blood. Anamnesis, course of the disease and the surgical procedure as well as especially the course of the metal values in the blood of the patient are presented. Possible causes for the excessive occurrence of metal abrasion, the systemic distribution and potential toxic effects of titanium are explained and discussed in detail. In addition, the currently available literature on the subject is critically examined.
引用
收藏
页码:1066 / 1071
页数:6
相关论文
共 50 条
  • [21] Comparison of Ten-Year Survivorship of Hip Prostheses with Use of Conventional Polyethylene, Metal-on-Metal, or Ceramic-on-Ceramic Bearings
    Milosev, Ingrid
    Kovac, Simon
    Trebse, Rihard
    Levasic, Vesna
    Pisot, Venceslav
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (19): : 1756 - 1763
  • [22] Metal-on-metal hip prostheses: Correlation between debris in the synovial fluid and levels of cobalt and chromium ions in the bloodstream
    De Pasquale, Dalila
    Stea, Susanna
    Squarzoni, Stefano
    Bordini, Barbara
    Amabile, Marilina
    Catalani, Simona
    Apostoli, Pietro
    Toni, Aldo
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (03) : 469 - 475
  • [23] Metal-on-metal hip prostheses: Correlation between debris in the synovial fluid and levels of cobalt and chromium ions in the bloodstream
    Dalila De Pasquale
    Susanna Stea
    Stefano Squarzoni
    Barbara Bordini
    Marilina Amabile
    Simona Catalani
    Pietro Apostoli
    Aldo Toni
    International Orthopaedics, 2014, 38 : 469 - 475
  • [24] Metal-on-Metal Hip Prostheses and Systemic Health: A Cross-Sectional Association Study 8 Years after Implantation
    Prentice, Jennifer R.
    Clark, Matthew J.
    Hoggard, Nigel
    Morton, Allison C.
    Tooth, Claire
    Paley, Martyn N.
    Stockley, Ian
    Hadjivassiliou, Marios
    Wilkinson, J. Mark
    PLOS ONE, 2013, 8 (06):
  • [25] Potential Application of Entangled Porous Titanium Alloy Metal Rubber in Artificial Lumbar Disc Prostheses
    Ren, Zhiying
    Huang, Jingfei
    Bai, Hongbai
    Jin, Rui
    Xu, Fangqi
    Xu, Jie
    JOURNAL OF BIONIC ENGINEERING, 2021, 18 (03) : 584 - 599
  • [26] Potential Application of Entangled Porous Titanium Alloy Metal Rubber in Artificial Lumbar Disc Prostheses
    Zhiying Ren
    Jingfei Huang
    Hongbai Bai
    Rui Jin
    Fangqi Xu
    Jie Xu
    Journal of Bionic Engineering, 2021, 18 : 584 - 599
  • [27] Systemic lupus erythematosus induced by adjuvants after metal-on-polyethylene total hip arthroplasty
    Wang Chang-Chao
    Huang Yan
    Huang Ya-Dong
    中华医学杂志英文版, 2020, 133 (12) : 1499 - 1500
  • [28] Systemic lupus erythematosus induced by adjuvants after metal-on-polyethylene total hip arthroplasty
    Wang, Chang-Chao
    Huang, Yan
    Huang, Ya-Dong
    CHINESE MEDICAL JOURNAL, 2020, 133 (12) : 1499 - 1500
  • [29] Is cemented metal-polyethylene 22.2 mm hip arthroplasty a gold standard? Results of a series of 105 primary arthroplasties at a minimum of ten years follow-up
    Mesnil, P.
    Vasseur, L.
    Wavreille, G.
    Fontaine, C.
    Duquennoy, A.
    Migaud, H.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (04) : 369 - 373
  • [30] A closed-form formulation for the conformal articulation of metal-on-polyethylene hip prostheses: Contact mechanics and sliding distance
    Askari, Ehsan
    Andersen, Michael S.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2018, 232 (12) : 1196 - 1208