Impingement of metal-polyethylene hip prostheses Potential cause of high systemic titanium levels?

被引:0
|
作者
Lutter, Christoph [1 ]
Kluess, Daniel [1 ]
Enz, Andreas [1 ]
Mittelmeier, Wolfram [1 ]
机构
[1] Univ Med Ctr Rostock, Dept Orthoped, Doberaner Str 142, D-18057 Rostock, Germany
来源
ORTHOPADE | 2020年 / 49卷 / 12期
关键词
Cobalt; Chromium; Nickel; Metal ions; EXERCISE-RELATED RISE; ION LEVELS; ARTHROPLASTY; BLOOD; SERUM; BEARINGS; DEBRIS;
D O I
10.1007/s00132-020-03998-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
High blood metal levels have been described in the past, primarily in metal-on-metal bearings. Other possible causes are often underestimated. This report presents the case of a 70-year-old female patient who suffered from pronounced neurological symptoms (especially fatigue and concentration problems) 13 years after implantation of a hip endoprosthesis with metal-polyethylene (ME-PE) bearing. An osteolysis in the pelvis and loosening of the acetabular component were detected. In addition, large quantities of metallic black discolored granulomas were detected in the periarticular environment during surgery. A ventral impingement with destruction of the titanium cup and the PE insert was identified as the suspected cause of this condition. The postoperative course of the blood metal levels was unexpected as titanium levels increased massively in the blood. Anamnesis, course of the disease and the surgical procedure as well as especially the course of the metal values in the blood of the patient are presented. Possible causes for the excessive occurrence of metal abrasion, the systemic distribution and potential toxic effects of titanium are explained and discussed in detail. In addition, the currently available literature on the subject is critically examined.
引用
收藏
页码:1066 / 1071
页数:6
相关论文
共 50 条
  • [1] Impingement of metal-polyethylene hip prostheses: Potential cause of high systemic titanium levels?; [Impingement von Metall-Polyethylen-Hüftprothesen: Mögliche Ursache für hohe systemische Titanwerte?]
    Lutter C.
    Klüß D.
    Enz A.
    Mittelmeier W.
    Der Orthopäde, 2020, 49 (12): : 1066 - 1071
  • [2] Results using patellar prostheses with metal-polyethylene backing
    Rader, CP
    Lohr, J
    Wittmann, R
    Eulert, J
    PROBLEMS OF TOTAL KNEE REPLACEMENT, 1997, : 66 - 72
  • [3] Mechanical failure of metal-polyethylene sandwich liner in metal-on-metal total hip replacement
    Oshima, Yasushi
    Fetto, Joseph F.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2015, 26 (01)
  • [4] Systemic toxicity related to metal hip prostheses
    Bradberry, S. M.
    Wilkinson, J. M.
    Ferner, R. E.
    CLINICAL TOXICOLOGY, 2014, 52 (08) : 837 - 847
  • [5] Ceramic-ceramic and metal-polyethylene total hip replacements - Comparison of pseudomembranes after loosening
    Lerouge, S
    Huk, O
    Yahia, L
    Witvoet, J
    Sedel, L
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (01): : 135 - 139
  • [6] Migration of metal-on-metal versus ceramic-on-polyethylene hip prostheses
    Pabinger, C
    Biedermann, R
    Stöckl, B
    Fischer, M
    Krismer, M
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (412) : 103 - 110
  • [7] Thermomechanical analysis of ultra-high molecular weight polyethylene-metal hip prostheses
    Rocchi, M.
    Affatato, S.
    Falasca, G.
    Viceconti, M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2007, 221 (H6) : 561 - 568
  • [8] Impingement of lesser trochanter on ischium as a potential cause for hip pain
    Patti, Jay W.
    Ouellette, Hugue
    Bredella, Miriam A.
    Torriani, Martin
    SKELETAL RADIOLOGY, 2008, 37 (10) : 939 - 941
  • [9] Impingement of lesser trochanter on ischium as a potential cause for hip pain
    Jay W. Patti
    Hugue Ouellette
    Miriam A. Bredella
    Martin Torriani
    Skeletal Radiology, 2008, 37 : 939 - 941
  • [10] The effect of clearance and wear on the contact pressure of metal on polyethylene hip prostheses
    Tudor, A.
    Laurian, T.
    Popescu, V. M.
    TRIBOLOGY INTERNATIONAL, 2013, 63 : 158 - 168