Post cataract-intraocular lens (IOL) surgery opacification

被引:68
作者
Trivedi, RH [1 ]
Werner, L [1 ]
Apple, DJ [1 ]
Pandey, SK [1 ]
Izak, AM [1 ]
机构
[1] Med Univ S Carolina, Storm Eye Inst, Dept Ophthalmol, Ctr Res Ocular Therapeut & Biodevices, Charleston, SC 29425 USA
关键词
intraocular lens; complication; opacification; anterior capsule opacification; silicone; calcification; glistening; snowflake; interlenticular opacification; piggyback; posterior capsule opacification;
D O I
10.1038/sj.eye.6700066
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Intraocular lens (IOL) implantation has no doubt been one of the most satisfying advances of medicine. Millions of individuals with visual disability or frank blindness from cataracts had and continue to have benefit from this procedure. It has been reported by ophthalmologists that the modem cataract-intraocular lens (IOL) surgery is safe and complication-free most of the time. This makes the watchword for any cataract surgeon to be 'implantation/ 'implantation,' 'implantation.' In the mid-1980s, as IOLs were evolving rapidly, the watchword of the implant surgeon was 'fixation,' 'fixation,' 'fixation.' Most techniques, lenses and surgical adjuncts now allow us to achieve the basic requirement for successful IOL implantation, namely long-term stable IOL fixation in the capsular bag. However despite this advancement some items 'slipped through cracks.' In this article, we would like to alert the reader to a new watchword, namely 'opacification,' 'opacification,' 'opacification.' Here we will be talking about the good, the bad, and the ugly. Examples of the 'good' include the recent successes now being achieved in reducing the incidence of posterior capsule opacification. Examples of the 'bad' include various proliferations of anterior capsule cells, problems caused by silicone oil adherence to IOLs and problems with piggyback IOLs. The 'ugly' include the sometimes striking and often visually disabling opacifications occurring on and within IOL optics, both on some modem foldable IOLs as well as a poly(methyl methacrylate) (PMMA) optic degradation occurring with some models a decade or more after implantation.
引用
收藏
页码:217 / 241
页数:25
相关论文
共 92 条
  • [1] Apple D J, 2000, Trans Am Ophthalmol Soc, V98, P257
  • [2] Apple D J, 2001, Trans Am Ophthalmol Soc, V99, P95
  • [3] Deposits on the optical surfaces of hydroview intraocular lenses
    Apple, DJ
    Werner, L
    Escobar-Gomez, M
    Pandey, SK
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (06) : 796 - 797
  • [4] Irreversible silicone oil adhesion to silicone intraocular lenses - A clinicopathologic analysis
    Apple, DJ
    Federman, JL
    Krolicki, TJ
    Sims, JCR
    Kent, DG
    Hamburger, HA
    Smiddy, WE
    Cox, MS
    Hassan, TS
    Compton, SM
    Thomas, SG
    [J]. OPHTHALMOLOGY, 1996, 103 (10) : 1555 - 1561
  • [5] Apple DJ, 2001, EYE, V15, P817, DOI 10.1038/eye.2001.270
  • [7] POSTERIOR CAPSULE OPACIFICATION
    APPLE, DJ
    SOLOMON, KD
    TETZ, MR
    ASSIA, EI
    HOLLAND, EY
    LEGLER, UFC
    TSAI, JC
    CASTANEDA, VE
    HOGGATT, JP
    KOSTICK, AMP
    [J]. SURVEY OF OPHTHALMOLOGY, 1992, 37 (02) : 73 - 116
  • [8] Apple DJ, 1999, ARCH OPHTHALMOL-CHIC, V117, P827
  • [9] Eradication of posterior capsule opacification -: Documentation. of a marked decrease in Nd:YAG laser posterior capsulotomy rates noted in an analysis of 5416 pseudophakic human eyes obtained postmortem
    Apple, DJ
    Peng, Q
    Visessook, N
    Werner, L
    Pandey, SK
    Escobar-Gomez, M
    Ram, J
    Auffarth, GU
    [J]. OPHTHALMOLOGY, 2001, 108 (03) : 505 - 518
  • [10] Apple DJ, 2001, ARCH OPHTHALMOL-CHIC, V119, P581