3D TEE During Catheter-Based Interventions

被引:64
作者
Faletra, Francesco Fulvio [1 ]
Pedrazzini, Giovanni [1 ]
Pasotti, Elena [1 ]
Muzzarelli, Stefano [1 ]
Dequarti, Maria Cristina [1 ]
Murzilli, Romina [1 ]
Schlossbauer, Susanne Anna [1 ]
Slater, Iveta Petrova [1 ]
Moccetti, Tiziano [1 ]
机构
[1] Cardioctr Ticino, Div Cardiol, Lugano, Switzerland
关键词
catheter-based percutaneous interventions; 2-dimensional transesophageal echocardiography; 3-dimensional transesophageal chocardiography; 3-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY; GUIDANCE; REPAIR; ANATOMY;
D O I
10.1016/j.jcmg.2013.10.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Guidance of catheter-based procedures is performed using fluoroscopy and 2-dimensional transesophageal echocardiography (TEE). Both of these imaging modalities have significant limitations. Because of its 3-dimensional (3D) nature, 3D TEE allows visualizing the entire scenario in which catheter-based procedures take place (including long segments of catheters, tips, and the devices) in a single 3D view. Despite these undeniable advantages, 3D TEE has not yet gained wide acceptance among most interventional cardiologists and echocardiographists. One reason for this reluctance is probably the absence of standardized approaches for obtaining 3D perspectives that provide the most comprehensive information for any single step of any specific procedure. Therefore, the purpose of this review is to describe what we believe to be the most useful 3D perspectives in the following catheter-based percutaneous interventions: transseptal puncture; patent foramen ovale/atrial septal defect closure; left atrial appendage occlusion; mitral valve repair; and closure of paravalvular leaks. (C) 2014 by the American College of Cardiology Foundation
引用
收藏
页码:292 / 308
页数:17
相关论文
共 15 条
[1]   Real-Time 3D TEE Allows Optimized Guidance of Percutaneous Edge-to-Edge Repair of the Mitral Valve [J].
Altiok, Ertunc ;
Becker, Michael ;
Hamada, Sandra ;
Grabskaya, Eva ;
Reith, Sebastian ;
Marx, Nikolaus ;
Hoffmann, Rainer .
JACC-CARDIOVASCULAR IMAGING, 2010, 3 (11) :1196-1198
[2]   Real-time three-dimensional transoesophageal echocardiography for guidance of non-coronary interventions in the catheter laboratory [J].
Balzer, Jan ;
Kelm, Malte ;
Kuehl, Harald P. .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (03) :341-349
[3]   Utility of Combined Two-Dimensional and Three-Dimensional Transesophageal Imaging for Catheter-Based Mitral Valve Clip Repair of Mitral Regurgitation [J].
Biner, Simon ;
Perk, Gila ;
Kar, Saibal ;
Rafique, Asim M. ;
Slater, James ;
Shiota, Takahiro ;
Hussaini, Asma ;
Chou, Stanley ;
Kronzon, Itzhak ;
Siegel, Robert J. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (06) :611-617
[4]   Role of Echocardiography in Percutaneous Mitral Valve Interventions [J].
Cavalcante, Joao L. ;
Rodriguez, L. Leonardo ;
Kapadia, Samir ;
Tuzcu, E. Murat ;
Stewart, William J. .
JACC-CARDIOVASCULAR IMAGING, 2012, 5 (07) :733-746
[5]   Left Atrial Appendage Exclusion: State-Of-The-Art [J].
Cruz-Gonzalez, Ignacio ;
Yan, Bryan P. ;
Lam, Yat-Yin .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 75 (05) :806-813
[6]   How to perform a transseptal puncture [J].
Earley, Mark J. .
HEART, 2009, 95 (01) :85-92
[7]   Real-Time 3-Dimensional Transesophageal Echocardiography During Double Percutaneous Mitral Edge-to-Edge Procedure [J].
Faletra, Francesco ;
Grimaldi, Antonio ;
Pasotti, Elena ;
Klimusina, Julija ;
Evangelista, Antonietta ;
Alfieri, Ottavio ;
Moccetti, Tiziano ;
Pedrazzini, Giovanni .
JACC-CARDIOVASCULAR IMAGING, 2009, 2 (08) :1031-1033
[8]   Imaging the Atrial Septum Using Real-Time Three-Dimensional Transesophageal Echocardiography: Technical Tips, Normal Anatomy, and Its Role in Transseptal Puncture [J].
Faletra, Francesco F. ;
Nucifora, Gaetano ;
Ho, Siew Yen .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (06) :593-599
[9]   Anatomy of Right Atrial Structures by Real-Time 3D Transesophageal Echocardiography [J].
Faletra, Francesco F. ;
Ho, Siew Y. ;
Auricchio, Angelo .
JACC-CARDIOVASCULAR IMAGING, 2010, 3 (09) :966-975
[10]   Role of real-time three dimensional transoesophageal echocardiography as guidance imaging modality during catheter based edge-to-edge mitral valve repair [J].
Faletra, Francesco Fulvio ;
Pedrazzini, Giovanni ;
Pasotti, Elena ;
Petrova, Iveta ;
Drasutiene, Agne ;
Dequarti, Maria Cristina ;
Muzzarelli, Stefano ;
Moccetti, Tiziano .
HEART, 2013, 99 (16) :1204-1215