The Practical Application of Ozone Gas as an Anti-fungal (Anti-mold) Agent

被引:18
作者
Hudson, James B. [1 ]
Sharma, Manju [1 ]
机构
[1] Viroforce Syst Inc Lab, Vancouver, BC, Canada
关键词
Ozone; Fungi; Mold; Anti-Fungal; Healthcare; Environmental Fungi; Stachybotrys chartarium; Trichoderma viride; ESCHERICHIA-COLI; INDOOR AIR; INACTIVATION; WATER; CARE;
D O I
10.1080/01919510903043996
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
We evaluated the ability of a portable ozone generating machine (Viroforce 1000) to inactivate 13 different species of environmental fungi. Samples, prepared as wet or dried films, were subjected to one or two cycles of treatment (35 ppm ozone for 20 minutes, with a short burst of >90% relative humidity), and measured for residual viability. Treatments could inactivate 3 log(10) cfu (colony forming units) of most of the fungi, both in the laboratory and in simulated field conditions, on various surfaces. We conclude that the ozone generator would be a valuable decontamination tool for mold removal in buildings.
引用
收藏
页码:326 / 332
页数:7
相关论文
共 20 条
[1]   Application of gaseous ozone to control populations of Escherichia coli, Bacillus cereus and Bacillus cereus spores in dried figs [J].
Akbas, Meltem Yesilcimen ;
Ozdemir, Murat .
FOOD MICROBIOLOGY, 2008, 25 (02) :386-391
[2]   Decontamination of Escherichia coli O157:H7 and Salmonella enterica on blueberries using ozone and pulsed UV-Light [J].
Bialka, K. L. ;
Demirci, A. .
JOURNAL OF FOOD SCIENCE, 2007, 72 (09) :M391-M396
[3]   Ozone degradation of biological macromolecules: Proteins, hemoglobin, RNA, and DNA [J].
Cataldo, Franco .
OZONE-SCIENCE & ENGINEERING, 2006, 28 (05) :317-328
[4]  
Gniadek A, 2007, ADV MED SCI-POLAND, V52, P283
[5]   Detection of Satratoxin G and H in indoor air from a water-damaged building [J].
Gottschalk, Christoph ;
Bauer, Johann ;
Meyer, Karsten .
MYCOPATHOLOGIA, 2008, 166 (02) :103-107
[6]   Excess dampness and mold growth in homes: An evidence-based review of the aeroirritant effect and its potential causes [J].
Hope, Andrew P. ;
Simon, Ronald A. .
ALLERGY AND ASTHMA PROCEEDINGS, 2007, 28 (03) :262-270
[7]   Inactivation of Norovirus by ozone gas in conditions relevant to healthcare [J].
Hudson, J. B. ;
Sharma, M. ;
Petric, M. .
JOURNAL OF HOSPITAL INFECTION, 2007, 66 (01) :40-45
[8]   Indoor air particles and bioaerosols before and after renovation of moisture-damaged buildings:: The effect on biological activity and microbial flora [J].
Huttunen, Kati ;
Rintala, Helena ;
Hirvonen, Maija-Riitta ;
Vepsalainen, Asko ;
Hyvarinen, Anne ;
Meklin, Teija ;
Toivola, Mika ;
Nevalainen, Aino .
ENVIRONMENTAL RESEARCH, 2008, 107 (03) :291-298
[9]   Characterization of airborne fungal levels after mold remediation [J].
Kleinheinz, G. T. ;
Langolf, B. M. ;
Englebert, E. .
MICROBIOLOGICAL RESEARCH, 2006, 161 (04) :367-376
[10]  
Korzun William, 2008, Clin Lab Sci, V21, P107