Direct determination of iron in acidified (pH 1.7) seawater samples by flow injection analysis with catalytic spectrophotometric detection: Application and intercomparison

被引:64
作者
Lohan, Maeve C. [1 ]
Aguilar-Islas, Ana M.
Bruland, Kenneth W.
机构
[1] Univ Calif Santa Cruz, Inst Marine Sci, Santa Cruz, CA 95064 USA
[2] Univ Plymouth, Sch Earth Ocean & Environm Sci, Plymouth PL4 8AA, Devon, England
[3] Univ Calif Santa Cruz, Dept Ocean Sci, Santa Cruz, CA 95064 USA
关键词
D O I
10.4319/lom.2006.4.164
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
A sensitive flow injection method for determining iron in seawater developed by Measures et al. (1995) has been substantially modified to allow the direct preconcentration of dissolved iron in acidified seawater samples (pH 1.7) onto a nitrilotriacetic acid (NTA) chelating resin. This removes the need to adjust the pH and buffer samples before the preconcentration step, and the low pH eliminates potential interference from the presence of strong iron-binding organic ligands. As part of an international intercalibration exercise for the Sampling and Analysis of Fe (SAFe), we investigated at sea the precision and accuracy of this flow injection method with its preconcentration step plus catalytic spectrophotometric detection with N,N-dimethyl-p-phenylenediamine dihydrochloride (FI-NTA-DPD). Acidified seawater samples analyzed using FI-NTA-DPD were shown to be in excellent agreement with other ship- and lab-based methods. The acidification of seawater samples to pH 1.7 is an important protocol if total dissolved iron in seawater is to be determined within hours of collection. A ship- and lab-based analytical intercomparison of two flow injection methods (FI-NTA-DPD and FI-NTA-ICP-SFMS) for the determination of total dissolved iron in seawater was carried out on SAFe samples collected from surface waters and at 1000 m depth from the North Pacific Ocean. For the two methods, total dissolved iron concentrations in surface samples were 0.101 +/- 0.009 and 0.098 +/- 0.009 nM, respectively, and in samples from 1000 m, 0.93 +/- 0.04 and 0.92 +/- 0.08 nM. No statistical difference between the FI-NTA-DPD and FI-NTA-ICP-SFMS methods was observed (P = 0.05).
引用
收藏
页码:164 / 171
页数:8
相关论文
共 21 条
[1]   Determination of iron in seawater [J].
Achterberg, EP ;
Holland, TW ;
Bowie, AR ;
Fauzi, R ;
Mantoura, C ;
Worsfold, PJ .
ANALYTICA CHIMICA ACTA, 2001, 442 (01) :1-14
[2]   Photochemical cycling of iron in the surface ocean mediated by microbial iron(III)-binding ligands [J].
Barbeau, K ;
Rue, EL ;
Bruland, KW ;
Butler, A .
NATURE, 2001, 413 (6854) :409-413
[3]   Analytical intercomparison between flow injection-chemiluminescence and flow injection-spectrophotometry for the determination of picomolar concentrations of iron in seawater [J].
Bowie, AR ;
Sedwick, PN ;
Worsfold, PJ .
LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2004, 2 :42-54
[4]  
Bruland K.W., 2001, BIOGEOCHEMISTRY IRON, P255
[5]   Iron, macronutrients and diatom blooms in the Peru upwelling regime: brown and blue waters of Peru [J].
Bruland, KW ;
Rue, EL ;
Smith, GJ ;
DiTullio, GR .
MARINE CHEMISTRY, 2005, 93 (2-4) :81-103
[6]   SAMPLING AND ANALYTICAL METHODS FOR THE DETERMINATION OF COPPER, CADMIUM, ZINC, AND NICKEL AT THE NANOGRAM PER LITER LEVEL IN SEA-WATER [J].
BRULAND, KW ;
FRANKS, RP ;
KNAUER, GA ;
MARTIN, JH .
ANALYTICA CHIMICA ACTA, 1979, 105 (01) :233-245
[7]   REACTIVE TRACE-METALS IN THE STRATIFIED CENTRAL NORTH PACIFIC [J].
BRULAND, KW ;
ORIANS, KJ ;
COWEN, JP .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1994, 58 (15) :3171-3182
[8]   DIRECT DETERMINATION OF DISSOLVED COBALT AND NICKEL IN SEAWATER BY DIFFERENTIAL PULSE CATHODIC STRIPPING VOLTAMMETRY PRECEDED BY ADSORPTIVE COLLECTION OF CYCLOHEXANE-1,2-DIONE DIOXIME COMPLEXES [J].
DONAT, JR ;
BRULAND, KW .
ANALYTICAL CHEMISTRY, 1988, 60 (03) :240-244
[9]   DETERMINATION OF COMPLEXATION OF IRON(III) WITH NATURAL ORGANIC COMPLEXING LIGANDS IN SEAWATER USING CATHODIC STRIPPING VOLTAMMETRY [J].
GLEDHILL, M ;
VAN DEN BERG, CMG .
MARINE CHEMISTRY, 1994, 47 (01) :41-54
[10]  
HURST MP, 2006, IN PRESS GEOCHIM COS