Hierarchical reserve allocation with air conditioning loads considering lock time using Benders decomposition

被引:18
作者
Cheng, Dingyi [1 ]
Zhang, Wen [1 ]
Wang, Kai [2 ]
机构
[1] Shandong Univ, Minist Educ, Key Lab Power Syst Intelligent Dispatch & Control, Jinan 250061, Shandong, Peoples R China
[2] State Grid Jibei Elect Power Co Ltd, Dispatch Ctr, Beijing 100054, Peoples R China
基金
美国国家科学基金会; 国家重点研发计划;
关键词
Air conditioning loads; Lock time; Reserve allocation; Hierarchical; Benders decomposition; DYNAMIC ECONOMIC-DISPATCH; DEMAND RESPONSE; ENERGY; DESIGN; OPTIMIZATION; TRANSMISSION; INTEGRATION; SECURITY; STORAGE; MODEL;
D O I
10.1016/j.ijepes.2019.03.014
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the integration of more and more renewable energy in the power system, more reserves are needed to cope with the intermittent and stochastic characteristics of the renewable energy. To relieve the stress of the reserve supply by the generation side, air conditioning loads can be considered to participate in reserve allocation in dynamic economic dispatch owing to their high proportion in the demand and thermal energy storage characteristics. The lock time of air conditioners should not be ignored since it can avoid the short cycling of compressor. This paper proposes a hierarchical reserve allocation model with air conditioning loads considering lock time to coordinate the power system dispatch and the control of air conditioning loads. An aggregate model of air conditioning loads considering the lock time is proposed and linear constraints of the air conditioning loads are developed. Among these constraints, lockout constraints are linear slack constraints for convenient in computation and the validity of the slack form has been proved. These constraints are integrated into the reserve allocation in dynamic economic dispatch. In such a state, the problem has multi-time scale characteristics and thus, is difficult to solve; therefore, this problem is reconstructed as a three-level hierarchical problem, and Benders decomposition is applied. The first level (operation level) represents the operation of the power system in normal conditions. Each N-1 contingency is placed in the second level (contingency level). The third level (load control level) considers the constraints of the air conditioning loads. To increase the calculation efficiency, we propose three methods, which are adding necessary conditions, adjusting upper bound and applying parallel computing. The simulation results show that air conditioning loads can realize load reserve, and the proposed hierarchical solving method is effective to solve the reserve allocation problem with air conditioning loads considering the lock time.
引用
收藏
页码:293 / 308
页数:16
相关论文
共 51 条
[1]  
Amini M.H., 2015, 2015 North American Power Symposium (NAPS), P1, DOI DOI 10.1109/NAPS.2015.7335100
[2]  
[Anonymous], BAL0020 NERC
[3]   Energy and reserve pricing in security and network-constrained electricity markets [J].
Arroyo, JM ;
Galiana, FD .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (02) :634-643
[4]   Probabilistic reserve schedule with demand-side participation [J].
Bai, J. ;
Gooi, H. B. ;
Xia, L. M. .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2008, 36 (02) :138-151
[5]   Partitioning procedures for solving mixed-variables programming problems [J].
Benders, J. F. .
COMPUTATIONAL MANAGEMENT SCIENCE, 2005, 2 (01) :3-19
[6]   A new benders decomposition approach to solve power transmission network design problems [J].
Binato, S ;
Pereira, MVF ;
Granville, S .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2001, 16 (02) :235-240
[7]   Market-clearing with stochastic security - Part I: Formulation [J].
Bouffard, F ;
Galiana, FD ;
Conejo, AJ .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (04) :1818-1826
[8]   Generation following with thermostatically controlled loads via alternating direction method of multipliers sharing algorithm [J].
Burger, Eric M. ;
Moura, Scott J. .
ELECTRIC POWER SYSTEMS RESEARCH, 2017, 146 :141-160
[9]   Achieving Controllability of Electric Loads [J].
Callaway, Duncan S. ;
Hiskens, Ian A. .
PROCEEDINGS OF THE IEEE, 2011, 99 (01) :184-199
[10]   Tapping the energy storage potential in electric loads to deliver load following and regulation, with application to wind energy [J].
Callaway, Duncan S. .
ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (05) :1389-1400