Intravascular ultrasound in the drug-eluting stent era

被引:106
作者
Mintz, Gary S.
Weissman, Neil J.
机构
[1] Cardiovasc Res Fdn, New York, NY USA
[2] Washington Hosp Ctr, Washington, DC USA
关键词
D O I
10.1016/j.jacc.2006.04.068
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Intravascular ultrasound (IVUS) has become an indispensable part of all drug-eluting stent (DES) studies; findings must be put into context with the IVUS findings in bare metal stents. Unfortunately, there is not yet a complete picture of either the Cypher (Cordis, Miami, Florida) or the Taxus (Boston Scientific, Maple Grove, Minnesota) stent (the two U.S. Food and Drug Administration-approved devices). Intimal hyperplasia volume in DES is reduced to < 15% of stent volume, but stent underexpansion continues to be a consistent finding in DES failures (restenosis and thrombosis). The utility of IVUS to assure adequate stent expansion may be more important whenever there are clinical risk factors for DES failure.
引用
收藏
页码:421 / 429
页数:9
相关论文
共 53 条
[1]   Sirolimus-eluting stents inhibit neointimal hyperplasia in diabetic patients - Insights from the RAVEL Trial [J].
Abizaid, A ;
Costa, MA ;
Blanchard, D ;
Albertal, M ;
Eltchaninoff, H ;
Guagliumi, G ;
Geert-Jan, L ;
Abizaid, AS ;
Sousa, AGMR ;
Wuelfert, E ;
Wietze, L ;
Sousa, JE ;
Serruys, PW ;
Morice, MC .
EUROPEAN HEART JOURNAL, 2004, 25 (02) :107-112
[2]   Long-term follow-up after percutaneous transluminal coronary angioplasty was not performed based on intravascular ultrasound findings - Importance of lumen dimensions [J].
Abizaid, AS ;
Mintz, GS ;
Mehran, R ;
Abizaid, A ;
Lansky, AJ ;
Pichard, AD ;
Satler, LF ;
Wu, HS ;
Pappas, C ;
Kent, KM ;
Leon, MB .
CIRCULATION, 1999, 100 (03) :256-261
[3]   Late incomplete stent apposition after sirolimus-eluting stent implantation - A serial intravascular ultrasound analysis [J].
Ako, J ;
Morino, Y ;
Honda, Y ;
Hassan, A ;
Sonoda, S ;
Yock, PG ;
Leon, MB ;
Moses, JW ;
Bonneau, HN ;
Fitzgerald, PJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (06) :1002-1005
[4]  
AKO J, 2005, CIRCULATION, V112, P1770
[5]   Peristent remodeling and neointimal suppression 2 years after polymer-based, paclitaxel-eluting stent implantation - Insights from serial intravascular ultrasound analysis in the TAXUS II study [J].
Aoki, J ;
Colombo, A ;
Dudek, D ;
Banning, AP ;
Drzewiecki, J ;
Zmudka, K ;
Schiele, F ;
Russell, ME ;
Koglin, J ;
Serruys, PW .
CIRCULATION, 2005, 112 (25) :3876-3883
[6]   Evaluation of four-year coronary artery response after sirolimus-eluting stent implantation using serial quantitative intravascular ultrasound and computer-assisted grayscale value analysis for plaque composition in event-free patients [J].
Aoki, J ;
Abizaid, AC ;
Serruys, PW ;
Ong, ATL ;
Boersma, E ;
Sousa, JE ;
Bruining, N .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (09) :1670-1676
[7]   Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions [J].
Colombo, A ;
Drzewiecki, J ;
Banning, A ;
Grube, E ;
Hauptmann, K ;
Silber, S ;
Dudek, D ;
Fort, S ;
Schiele, F ;
Zmudka, K ;
Guagliumi, G ;
Russell, ME .
CIRCULATION, 2003, 108 (07) :788-794
[8]  
Cook S, 2006, J AM COLL CARDIOL, V47, p9B
[9]  
Costa JD, 2006, J AM COLL CARDIOL, V47, p11B
[10]   Intravascular ultrasound characterization of the "black hole" phenomenon after drug-eluting stent implantation [J].
Costa, MA ;
Sabate, M ;
Angiolillo, DJ ;
Jimenez-Quevedo, P ;
Teirstein, P ;
Carter, A ;
Leon, MB ;
Moses, J ;
Zenni, M ;
Yakubov, S ;
Guzman, LA ;
Gilmore, P ;
Macaya, C ;
Bass, TA .
AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (02) :203-206