LOAD-POWER RELATIONSHIP DURING A COUNTERMOVEMENT JUMP: A JOINT LEVEL ANALYSIS

被引:6
作者
Williams, Kym J. [1 ,2 ,3 ]
Chapman, Dale W. [2 ,4 ]
Phillips, Elissa J. [5 ]
Ball, Nick B. [2 ]
机构
[1] Australian Inst Sport, Strength & Conditioning, Bruce, Australia
[2] Univ Canberra, Res Inst Sport & Exercise, Bruce, Australia
[3] Flinders Univ S Australia, Coll Educ Psychol & Social Work, Bedford Pk, SA, Australia
[4] Australian Inst Sport, Physiol, Bruce, Australia
[5] Australian Inst Sport, Movement Sci, Bruce, Australia
关键词
jump profiling; force-velocity relationship; optimal load; BODY RESISTANCE EXERCISES; ATHLETIC PERFORMANCE; MAXIMUM STRENGTH; PEAK POWER; SQUATS; OUTPUT; MUSCLE; FORCE; SPECIFICITY; ABILITY;
D O I
10.1519/JSC.0000000000002432
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
This study aimed to investigate whether hip, knee, and ankle peak power is influenced by the relative load lifted, altering the joint and system load-power relationship during a countermovement jump (CMJ). Twenty-three male national representative athletes (age: 20.3 +/- 3.1 years, squat 1 repetition maximum [1RM]: 133.8 +/- 24.8 kg) completed 3 CMJs at relative barbell loads of 0, 10, 20, 30, and 40% of an athlete's estimated back squat 1RM. Ground reaction force and joint kinematics were captured using a 16 camera motion capture array integrated with 2 in-ground triaxial force plates. Hip ((x) over tilde = 20%, range 0. 40%), knee ((x) over tilde = 0%, 0. 20%), and ankle ((x) over tilde = 40%, 0. 40%) peak power was maximized at different percentages of absolute strength, with an athlete-dependent variation in load-power profiles observed across all lower-body joints. A decrease in system (body + barbell mass) peak power was significantly (p <= 0.05, r = 0.45) correlated with a reduction in knee peak power. Timing of instantaneous system and hip peak power occurred significantly closer to toe-off as load increased. The findings highlight that the generation and translation of lower-body joint power is influenced by external load and athlete-dependent traits. This subsequently alters the load-power profile at a system level, explaining the broad spectrums of loads reported to optimize system power during a CMJ. When training, we recommend that a combination of barbell loads based on assorted percentages of the estimated 1RM be prescribed to optimize joint and system power during a CMJ.
引用
收藏
页码:955 / 961
页数:7
相关论文
共 33 条
[31]   The Optimal Load for Maximal Power Production During Upper-Body Resistance Exercises: A Meta-Analysis [J].
Marco Antonio Soriano ;
Timothy J. Suchomel ;
Pedro J. Marín .
Sports Medicine, 2017, 47 :757-768
[32]   The Optimal Load for Maximal Power Production During Lower-Body Resistance Exercises: A Meta-Analysis [J].
Marco A. Soriano ;
Pedro Jiménez-Reyes ;
Matthew R. Rhea ;
Pedro J. Marín .
Sports Medicine, 2015, 45 :1191-1205
[33]   Case study: The influence of Achilles tendon rupture on knee joint stress during counter-movement jump-Combining musculoskeletal modeling and finite element analysis [J].
Lu, Zhenghui ;
Sun, Dong ;
Kovacs, Balint ;
Radak, Zsolt ;
Gu, Yaodong .
HELIYON, 2023, 9 (08)