A System Transient Stability Enhancement Control Method Using Doubly Fed Induction Generator Wind Turbine with Considering Its Power Constraints

被引:8
作者
Zheng, Di [1 ]
Ouyang, Jinxin [1 ]
Xiong, Xiaofu [1 ]
Xiao, Chao [1 ]
Li, Mengyang [1 ]
机构
[1] Chongqing Univ, Sch Elect Engn, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400044, Peoples R China
关键词
doubly fed induction generator; transient stability; rotor speed; reactive power; short circuit; RIDE-THROUGH; DFIG;
D O I
10.3390/en11040945
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With the rapid development of wind power, the effects of doubly fed induction generators (DFIGs) on the transient stability of power system have attracted more attention. However, the effects are still not clear due to the lack of deep and theoretical analysis. A control method for enhancing system rotor angle stability enhancement is proposed with considering the power constraints of DFIG. The rotor angle oscillation of the synchronous generator (SG) can be reduced and overspeed and the overcurrent of DFIG can be avoided. In this paper, the effects of the DFIG on the rotor angle characteristics of SG are analyzed. The change law of system rotor angle varying with transient power of the DFIG is obtained. Then, the power equation in the emergency pitch control process is explored. The reactive power constraints of the stator and grid-side converter are deduced. Finally, the system rotor angle stability enhancement control method is proposed based on the power constraints of DFIG. The effectiveness of proposed method is proven by simulations.
引用
收藏
页数:14
相关论文
共 18 条
[1]  
[Anonymous], WIND EN 2050 SHAP NE
[2]  
[Anonymous], MATH PROBL ENG
[3]   Power angle control of grid-connected doubly fed induction generator wind turbines for fault ride-through [J].
Bu, S. Qiqi ;
Du, Wenjuan ;
Wang, Haifeng F. ;
Gao, S. .
IET RENEWABLE POWER GENERATION, 2013, 7 (01) :18-27
[4]  
Cheng N., 2012, MILITARY COMMUNICATIONS CONFERENCE, MILCOM 2012, P1, DOI DOI 10.1109/MILC0M.2012.6415713
[5]   Low-voltage ride-through of a full converter wind turbine with permanent magnet generator [J].
Conroy, J. F. ;
Watson, R. .
IET RENEWABLE POWER GENERATION, 2007, 1 (03) :182-189
[6]   Impacts of High Penetration of DFIG Wind Turbines on Rotor Angle Stability of Power Systems [J].
Edrah, Mohamed ;
Lo, Kwok L. ;
Anaya-Lara, Olimpo .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2015, 6 (03) :759-766
[7]   Reactive Power Capability of Wind Turbines Based on Doubly Fed Induction Generators [J].
Engelhardt, Stephan ;
Erlich, Istvan ;
Feltes, Christian ;
Kretschmann, Joerg ;
Shewarega, Fekadu .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (01) :364-372
[8]   Impact of Increased Penetration of DFIG-Based Wind Turbine Generators on Transient and Small Signal Stability of Power Systems [J].
Gautam, Durga ;
Vittal, Vijay ;
Harbour, Terry .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2009, 24 (03) :1426-1434
[9]   Inertia Provision and Estimation of PLL-Based DFIG Wind Turbines [J].
He, Wei ;
Yuan, Xiaoming ;
Hu, Jiabing .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (01) :510-521
[10]  
Huang Y., 2009, P INT C SUSTAINABLE, P1