Analysing on Characteristics of Lightning Shielding Failure of UHVAC Double Circuit Transmission Line Based on Leader Progression Method

被引:0
|
作者
Wang, Zhiyong [1 ]
Wang, Shaoan [2 ]
Yu, Zhanqing [2 ]
Geng, Yinan [2 ]
Zeng, Rong [2 ]
He, Jinliang [2 ]
Li, Zhizhao [2 ]
机构
[1] China Southern Power Grid Co LTD, Guangzhou Power Supply Bur, Guangzhou 510620, Guangdong, Peoples R China
[2] Tsinghua Univ, State Key Lab Control & Simulat Power Syst & Gene, Dept Elect Engn, Beijing 100084, Peoples R China
关键词
STROKES; GAPS;
D O I
10.1109/APEMC.2010.5475688
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Shielding failure of lightning is the key problem for safe operation of UHV transmission lines. Taking the feature of 1000KV AC double circuit transmission lines into account, the leader progression method with proper criterion was employed. The lightning shielding failure rate of top phase, middle phase and bottom phase of two different transmission line tower types were compute, in three different geography conditions. The research work is helpful for improving the lightning performance of UHV transmission lines.
引用
收藏
页码:1582 / 1585
页数:4
相关论文
共 50 条
  • [31] Estimation of shielding failure number of transmission lines for different trace configurations using leader progression analysis
    Yahyaabadi, M.
    Vahidi, B.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 38 (01) : 27 - 32
  • [32] Fractal-based lightning model for shielding failure rate calculation of transmission lines
    Rahiminejad, Abolfazl
    Vahidi, Behrooz
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2018, 12 (06) : 719 - 725
  • [33] Experiment on the Hillside Effects of Lightning Shielding of Ultrahigh Voltage Common Tower Double-Circuit Transmission Lines
    Liu, Zongxi
    Wen, Xishan
    Wang, Yu
    Pan, Zhuohong
    An, Yunzhu
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2016, 44 (08) : 1442 - 1448
  • [34] Calculation Research on Influence of Adjacent Lines on Lightning Shielding Failure of ±1100 kV DC Transmission Line
    Wen X.
    Deng Y.
    Wang L.
    He H.
    Wang Y.
    Sun Z.
    Wang, Yu (wy_20002@163.com), 1600, Power System Technology Press (41): : 3420 - 3426
  • [35] Shielding failure lightning protection of 500kV quadruple-circuit transmission lines on the same tower
    Yu, Shifeng
    Ruan, Jiangjun
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 1705 - 1708
  • [37] Identification of Back Flash and Shielding Failure on Transmission Line Based on Time Domain Characteristics of Traveling Wave
    Liu, Yadong
    Sheng, Gehao
    Hu, Yun
    Jiang, Xiuchen
    Sun, Yue
    Wang, Shiqiang
    2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [38] Forecast on Failure Characteristics of Transmission Line Galloping Based on Neural Networks Method
    Zhang, Lichun
    Zhao, Bin
    Han, Jingshan
    Yang, Jialun
    Liu, Bin
    Ji, Kunpeng
    2019 6TH INTERNATIONAL CONFERENCE ON INFORMATION SCIENCE AND CONTROL ENGINEERING (ICISCE 2019), 2019, : 292 - 296
  • [39] Experimental test on corona characteristics of rigid jumper for 1 000 kV UHVAC double circuit transmission lines on the same tower
    Quan, Shanshan
    Xie, Liang
    Gu, Lili
    Cao, Jing
    Peng, Zongren
    Chen, Xiaohai
    Dianwang Jishu/Power System Technology, 2014, 38 (03): : 802 - 806
  • [40] A Metamodeling Approach for Leader Progression Model-based Shielding Failure Rate Calculation of Transmission Lines Using Artificial Neural Networks
    Tavakoli, Mohammad Reza Bank
    Vahidi, Behrooz