Videotaped helical CT images for lung cancer screening

被引:8
作者
Iwano, S
Makino, N
Ikeda, M
Itoh, S
Ishihara, S
Tadokoro, M
Ishigaki, T
机构
[1] Toyota Mem Hosp, Dept Radiol, Toyota, Aichi 4710821, Japan
[2] Nagoya Univ Hosp, Dept Med Informat & Med Records, Nagoya, Aichi, Japan
[3] Nagoya Univ, Sch Med, Dept Tech Radiol, Nagoya, Aichi 466, Japan
[4] Nagoya Univ, Sch Med, Dept Radiol, Nagoya, Aichi 466, Japan
关键词
computed tomography; helical; lungs; neoplasms; cancer; screening;
D O I
10.1097/00004728-200003000-00010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The goal of this work was to determine a radiologist's ability to detect solitary pulmonary nodules on helical CT using both video (cine) viewing and film-based viewing. Methods Sixty-five chest helical CT studies were reviewed. Six radiologists searched for 40 lung nodules on CT images presented in three formats. Film-based viewing of images at 10 and 5 mm increments was performed with a light box. Video viewing of the same examinations was performed in 5 mm increments at 2 frames/s, The area under the receiver operating characteristic curve (A(z)) measured the observers ability to detect nodules. Results: The A(z) was 0.948 for the video viewing, 0.844 for 5 mm increment film-based viewing, and 0.879 for 10 mm increment film-based viewing, There were no statistically significant differences. Conclusion: Lung nodules can be detected with similar defection rates when viewing conventional film or videotaped helical CT images. Videotaped images incur a lower cost, an important consideration in mass screening for lung cancer.
引用
收藏
页码:242 / 246
页数:5
相关论文
共 21 条
[11]   Ultra low-dose helical CT of the chest [J].
Nitta, N ;
Takahashi, M ;
Murata, K ;
Morita, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (02) :383-385
[12]  
Obuchi Masao, 1997, Nippon Acta Radiologica, V57, P12
[13]   Dorfman-Berbaum-Metz method for statistical analysis of multireader, multimodality receiver operating characteristic data: Validation with computer simulation [J].
Roe, CA ;
Metz, CE .
ACADEMIC RADIOLOGY, 1997, 4 (04) :298-303
[14]   Pulmonary nodule detection: Low-dose versus conventional CT [J].
Rusinek, H ;
Naidich, DP ;
McGuinness, G ;
Leitman, BS ;
McCauley, DI ;
Krinsky, GA ;
Clayton, K ;
Cohen, H .
RADIOLOGY, 1998, 209 (01) :243-249
[15]   Influence of CT image size and format on accuracy of lung nodule detection [J].
Seltzer, SE ;
Judy, PF ;
Feldman, U ;
Scarff, L ;
Jacobson, FL .
RADIOLOGY, 1998, 206 (03) :617-622
[16]   SPIRAL CT OF THE CHEST - COMPARISON OF CINE AND FILM-BASED VIEWING [J].
SELTZER, SE ;
JUDY, PF ;
ADAMS, DF ;
JACOBSON, FL ;
STARK, P ;
KIKINIS, R ;
SWENSSON, RG ;
HOOTON, S ;
HEAD, B ;
FELDMAN, U .
RADIOLOGY, 1995, 197 (01) :73-78
[17]  
SODA H, 1993, CANCER-AM CANCER SOC, V72, P2341, DOI 10.1002/1097-0142(19931015)72:8<2341::AID-CNCR2820720809>3.0.CO
[18]  
2-A
[19]   Mass screening for lung cancer with mobile spiral computed tomography scanner [J].
Sone, S ;
Takashima, S ;
Li, F ;
Yang, ZG ;
Honda, T ;
Maruyama, Y ;
Hasegawa, M ;
Yamanda, T ;
Kubo, K ;
Hanamura, K ;
Asakura, K .
LANCET, 1998, 351 (9111) :1242-1245
[20]   Detection of pulmonary nodules with helical CT: Comparison of cine and film-based viewing [J].
Tillich, M ;
Kammerhuber, F ;
Reittner, P ;
Riepl, T ;
Stoeffler, G ;
Szolar, DH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (06) :1611-1614