Root Canal Surface Strain and Canal Center Transportation Induced by 3 Different Nickel-Titanium Rotary Instrument Systems

被引:19
作者
Liu, Wenzhe [1 ,2 ]
Wu, Buling [1 ,2 ]
机构
[1] Southern Med Univ, Nanfang Hosp, Dept Stomatol, 1838 North Guangzhou Ave, Guangzhou 510515, Guangdong, Peoples R China
[2] Southern Med Univ, Coll Stomatol, Guangzhou 510515, Guangdong, Peoples R China
关键词
Canal center transportation; nickel-titanium; ProTaper Next; root surface strain; Wave One; MICRO-COMPUTED-TOMOGRAPHY; NI-TI; PROTAPER SYSTEM; RECIPROCATING FILES; SHAPING ABILITY; HAND; UNIVERSAL;
D O I
10.1016/j.joen.2015.10.023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Root canal anatomy and canal preparation instruments affect the outcome of endodontic treatment. The purpose of this study was to determine the root surface strain (SS) generated and the extent of canal center transportation during canal shaping using 3 different nickel-titanium instruments. Methods: Simulated root canals in resin blocks (n = 10 per group) were prepared using adaptive rotary motion with twisted files (Twisted File Adaptive [TFA]; SybronEndo, Orange, CA), reciprocating rotary motion with WaveOne (WO; Dentsply Maillefer, Ballaigues, Switzerland) files, and continuous rotary motion with ProTaper Next files (PTN, Dentsply Maillefer). Electrical strain gauges at 3 sites recorded SS real time during canal shaping, and the blocks were scanned by micro computed tomographic imaging to assess the canal center deviation at 3 sections after root canal instrumentation. The mean maximum SS and the canal center transportation for all groups and sites were derived and analyzed for a possible correlation between them. Results: An overall increase in root SS was observed after root canal instrumentation. A significant difference in the induced mean maximum SS between TFA, WO, and PTN at specific sites of curved root canals was observed. A statistically significant difference in the mean distance of canal center transportation was observed among the 3 shaping techniques at the apical section. Finally, the mean maximum SS values induced during canal shaping strongly correlated with canal center transportation in the apical section and the coronal section. Conclusions: The curved canals prepared using TFA exhibited lower SS and less canal center transportation at the apical section than the WO and PTN systems. SS generated during canal shaping correlated with canal center transportation in a site-specific manner.
引用
收藏
页码:299 / 303
页数:5
相关论文
共 29 条
[1]   Crack Initiation on the Apical Root Surface Caused by Three Different Nickel-Titanium Rotary Files at Different Working Lengths [J].
Adorno, Carlos G. ;
Yoshioka, Takatomo ;
Suda, Hideaki .
JOURNAL OF ENDODONTICS, 2011, 37 (04) :522-525
[2]   Comparison of two stainless steel files to shape simulated root canals [J].
AlOmari, MAO ;
Bryant, S ;
Dummer, PMH .
INTERNATIONAL ENDODONTIC JOURNAL, 1997, 30 (01) :35-45
[3]   A methodology for quantitative evaluation of root canal instrumentation using microcomputed tomography [J].
Bergmans, L ;
Van Cleynenbreugel, J ;
Wevers, M ;
Lambrechts, P .
INTERNATIONAL ENDODONTIC JOURNAL, 2001, 34 (05) :390-398
[4]  
Bergmans L, 2001, AM J DENT, V14, P324
[5]   Canal Shaping with WaveOne Primary Reciprocating Files and ProTaper System: A Comparative Study [J].
Berutti, Elio ;
Chiandussi, Giorgio ;
Paolino, Davide Salvatore ;
Scotti, Nicola ;
Cantatore, Giuseppe ;
Castellucci, Arnaldo ;
Pasqualini, Damiano .
JOURNAL OF ENDODONTICS, 2012, 38 (04) :505-509
[6]  
Buchanan L S, 1994, Dent Today, V13, P52
[7]   Incidence of Dentinal Defects after Root Canal Preparation: Reciprocating versus Rotary Instrumentation [J].
Buerklein, Sebastian ;
Tsotsis, Polymnia ;
Schaefer, Edgar .
JOURNAL OF ENDODONTICS, 2013, 39 (04) :501-504
[8]   Effects of ProTaper Universal, ProTaper Next, and HyFlex Instruments on Crack Formation in Dentin [J].
Capar, Ismail Davut ;
Arslan, Hakan ;
Akcay, Merve ;
Uysal, Banu .
JOURNAL OF ENDODONTICS, 2014, 40 (09) :1482-1484
[9]   Analysis of Ni-Ti versus stainless steel instrumentation in resin simulated canals [J].
Coleman, CL ;
Svec, TA .
JOURNAL OF ENDODONTICS, 1997, 23 (04) :232-235
[10]   Micro-computed Tomographic Assessment on the Effect of ProTaper Next and Twisted File Adaptive Systems on Dentinal Cracks [J].
De-Deus, Gustavo ;
Belladonna, Felipe Goncalves ;
Souza, Erick Miranda ;
Nogueira Leal Silva, Emmanuel Joao ;
Neves, Aline de Almeida ;
Alves, Haimon ;
Lopes, Ricardo Tadeu ;
Versiani, Marco Aurelio .
JOURNAL OF ENDODONTICS, 2015, 41 (07) :1116-1119