The Value of Automated Diabetic Retinopathy Screening with the EyeArt System: A Study of More Than 100,000 Consecutive Encounters from People with Diabetes

被引:113
作者
Bhaskaranand, Malavika [1 ]
Ramachandra, Chaithanya [1 ]
Bhat, Sandeep [1 ]
Cuadros, Jorge [2 ]
Nittala, Muneeswar G. [3 ]
Sadda, Srinivas R. [3 ]
Solanki, Kaushal [1 ]
机构
[1] Eyenuk Inc, 5850 Canoga Ave,Suite 250, Los Angeles, CA 91367 USA
[2] EyePACS LLC, San Jose, CA USA
[3] Doheny Eye Inst, 1355 San Pablo St, Los Angeles, CA 90033 USA
基金
美国国家卫生研究院;
关键词
artificial intelligence; automation; diabetic retinopathy; screening; IMAGE ASSESSMENT SOFTWARE; CARE; VALIDATION;
D O I
10.1089/dia.2019.0164
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Current manual diabetic retinopathy (DR) screening using eye care experts cannot scale to screen the growing population of diabetes patients who are at risk for vision loss. EyeArt system is an automated, cloud-based artificial intelligence (AI) eye screening technology designed to easily detect referral-warranted DR immediately through automated analysis of patient's retinal images. Methods: This retrospective study assessed the diagnostic efficacy of the EyeArt system v2.0 analyzing 850,908 fundus images from 101,710 consecutive patient visits, collected from 404 primary care clinics. Presence or absence of referral-warranted DR (more than mild nonproliferative DR [NPDR]) was automatically detected by the EyeArt system for each patient encounter, and its performance was compared against a clinical reference standard of quality-assured grading by rigorously trained certified ophthalmologists and optometrists. Results: Of the 101,710 visits, 75.7% were nonreferable, 19.3% were referable to an eye care specialist, and in 5.0%, the DR level was unknown as per the clinical reference standard. EyeArt screening had 91.3% (95% confidence interval [CI]: 90.9-91.7) sensitivity and 91.1% (95% CI: 90.9-91.3) specificity. For 5446 encounters with potentially treatable DR (more than moderate NPDR and/or diabetic macular edema), the system provided a positive "refer" output to 5363 encounters achieving sensitivity of 98.5%. Conclusions: This study captures variations in real-world clinical practice and shows that an AI DR screening system can be safe and effective in the real world. This study demonstrates the value of this easy-to-use, automated tool for endocrinologists, diabetologists, and general practitioners to address the growing need for DR screening and monitoring.
引用
收藏
页码:635 / 643
页数:9
相关论文
共 31 条
  • [1] Abramoff MD, 2015, TELEOPHTHALMOLOGY PR, P41
  • [2] Pivotal trial of an autonomous AI-based diagnostic system for detection of diabetic retinopathy in primary care offices
    Abramoff, Michael D.
    Lavin, Philip T.
    Birch, Michele
    Shah, Nilay
    Folk, James C.
    [J]. NPJ DIGITAL MEDICINE, 2018, 1
  • [3] Automated Early Detection of Diabetic Retinopathy
    Abramoff, Michael D.
    Reinhardt, Joseph M.
    Russell, Stephen R.
    Folk, James C.
    Mahajan, Vinit B.
    Niemeijer, Meindert
    Quellec, Gwenole
    [J]. OPHTHALMOLOGY, 2010, 117 (06) : 1147 - 1154
  • [4] Evaluation of a System for Automatic Detection of Diabetic Retinopathy From Color Fundus Photographs in a Large Population of Patients With Diabetes
    Abramoff, Michael D.
    Niemeijer, Meindert
    Suttorp-Schulten, Maria S. A.
    Viergever, Max A.
    Russell, Stephen R.
    van Ginneken, Bram
    [J]. DIABETES CARE, 2008, 31 (02) : 193 - 198
  • [5] [Anonymous], DIAB 2018
  • [6] [Anonymous], 2017, NAT DIAB STAT REP
  • [7] [Anonymous], 2017, Diabetic Retinopathy PPP - Updated 2017
  • [8] [Anonymous], 2015, Eur. Ophthalmic Rev, DOI DOI 10.17925/EOR.2015.09.01.49
  • [9] Bhaskaranand M., 2016, J DIABETES SCI TECHN, V10, P254, DOI DOI 10.1177/1932296816628546
  • [10] Diabetic retinopathy management guidelines
    Chakrabarti, Rahul
    Harper, C. Alex
    Keeffe, Jill Elizabeth
    [J]. EXPERT REVIEW OF OPHTHALMOLOGY, 2012, 7 (05) : 417 - 439