Evacuated tube solar collector performance using CeO2/water nanofluid

被引:115
作者
Sharafeldin, M. A. [1 ,2 ]
Grof, Gyula [1 ]
机构
[1] Budapest Univ Technol & Econ, Budapest, Hungary
[2] Benha Univ, Fac Engn Shoubra, Mech Engn Dept, Banha, Egypt
关键词
Evacuated tube; Solar collector; Collector efficiency; CeO2-Water nanofluid; THERMAL PERFORMANCE; WATER NANOFLUID; FLAT-PLATE; EFFICIENCY; RECEIVER; ENERGY; PURE;
D O I
10.1016/j.jclepro.2018.03.054
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Nanofluids are the most attractive mean to enhance the performance of heat transfer devices. Several types of nanoparticles were utilized as they have high thermal conductivity. Renewable energy makes use of these nanofluids special in solar collectors. Evacuated tube solar collector is one of the most utilized solar collectors in thermal applications. CeO2 nanoparticles were used in the presented study. The mean diameter of CeO2 was 25 nm. A stable CeO2/water was made. The stability was checked using Zeta potential machine. Experiments were carried out using three different volume concentration of CeO2 nanoparticles of 0.015%, 0.025%, and 0.035%. The thermal performance of the evacuated tube solar collector was examined at different mass flux rates. Results showed that the temperature difference between inlet and outlet flow and absorbed energy increase when nanofluids are used. The volume fraction flow rate of 0.035% at the mass flux rate of 0.017 kg/s.m(2) had the maximum heat removable factor, the thermo-optical characteristic of the collector, and the thermal loss coefficient. The thermo-optical characteristic of the collector of tube solar corrector is raised up to 34%. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:347 / 356
页数:10
相关论文
共 36 条
[1]  
Al-Mashat SMS., 2013, Journal of Engineering, V19, P613
[2]  
[Anonymous], 2003, 932003 ASHRAE
[3]   Comparative field performance study of flat plate and heat pipe evacuated tube collectors (ETCs) for domestic water heating systems in a temperate climate [J].
Ayompe, L. M. ;
Duffy, A. ;
Mc Keever, M. ;
Conlon, M. ;
McCormack, S. J. .
ENERGY, 2011, 36 (05) :3370-3378
[4]   Parametric investigation of nanofluids utilization in parabolic trough collectors [J].
Bellos, Evangelos ;
Tzivanidis, Christos .
THERMAL SCIENCE AND ENGINEERING PROGRESS, 2017, 2 :71-79
[5]  
Chougule S. S., 2012, 2012 International Conference on Advances in Engineering, Science and Management (ICAESM), P247
[6]   Effects of different working fluid use on the energy and exergy performance for evacuated tube solar collector with thermosyphon heat pipe [J].
Ersoz, Mustafa Ali .
RENEWABLE ENERGY, 2016, 96 :244-256
[7]   Experimental investigation of a two-phase closed thermosyphon solar water heater [J].
Esen, M ;
Esen, H .
SOLAR ENERGY, 2005, 79 (05) :459-468
[8]   Thermal performance of a solar cooker integrated vacuum-tube collector with heat pipes containing different refrigerants [J].
Esen, M .
SOLAR ENERGY, 2004, 76 (06) :751-757
[9]   Performance of copper oxide/distilled water nanofluid in evacuated tube solar collector (ETSC) water heater with internal coil under thermosyphon system circulations [J].
Ghaderian, Javad ;
Sidik, Nor Azwadi Che ;
Kasaeian, Alibakhsh ;
Ghaderian, Sepideh ;
Okhovat, Amir ;
Pakzadeh, Amirabbas ;
Samion, Syahrullail ;
Yahya, Wira Jazair .
APPLIED THERMAL ENGINEERING, 2017, 121 :520-536
[10]   An experimental investigation on the effect of Al2O3/distilled water nanofluid on the energy efficiency of evacuated tube solar collector [J].
Ghaderian, Javad ;
Sidik, Nor Azwadi Che .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 108 :972-987