Clinical immunogenicity and tolerance studies of liquid vaccines delivered by jet-injector and a new single-use cartridge (Imule(R)): Comparison with standard syringe injection

被引:34
作者
duChatelet, IP
Lang, J
Schlumberger, M
Vidor, E
Soula, G
Genet, A
Standaert, SM
Saliou, P
Gueye, A
Julien, H
Lafaix, C
Lemardeley, P
Monnereau, A
Spiegel, A
Soke, M
Varichon, JP
机构
[1] PASTEUR MERIEUX SERUMS & VACCINS, F-69007 LYON, FRANCE
[2] ASSOC AIDE MED PREVENT, F-92430 MARNES LA COQUETTE, FRANCE
[3] CTR MURAZ OCCGE, BOBO BIOULASSO, BURKINA FASO
[4] MED DIST VELINGARA, VELINGARA, SENEGAL
[5] FIREMEN BRIGADE PARIS, PARIS, FRANCE
[6] VILLENEUVE ST GEORGES HOSP, VILLENEUVE, FRANCE
[7] LEGOUEST ARMY TEACHING HOSP, METZ, FRANCE
[8] AMP, KOLDA, SENEGAL
[9] BEGIN ARMY TEACHING HOSP, ST MANDE, FRANCE
[10] MED DIST ZOUDWEOGO, ZOUDWEOGO, BURKINA FASO
[11] TONKIN CLIN, VILLEURBANNE, FRANCE
关键词
jet-injector; clinical trials; review; vaccines; immunogenicity; tolerance;
D O I
10.1016/S0264-410X(96)00173-9
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
A new needleless jet-injector, Mini-Imojet(R), was developed that administers liquid vaccines from a single-use, pre-filled cartridge named Imule(R), which avoids the risk of cross-contamination. We conducted clinical trials in several settings in France and West Africa to compare the immunogenicity and tolerance of five vaccines (influenza vaccine, Vi capsular polysaccharide typhoid vaccine, tetanus toroid vaccine, diphtheria-tetanus-whole cell pertussis vaccine, and inactivated hepatitis A vaccine) administered with the Imule(R) system vs standard syringe technique. In each vaccine study, all subjects of either group were tested for serum antibody titres to calculate the geometrical mean titres and seroconversion rates after complete vaccination. Immediate local reactions were noted after each injection, and local and general reactions were evaluated during a predetermined period of follow-up. When delivered by the Imule(R) technique, all the administrated vaccines were of equivalent or superior immunogenicity, compared to the syringe technique. The tolerance to vaccines injected by the Imule(R) system was acceptable in all studies. The most frequently observed reactions were mild (e.g. minor bleeding, superficial papules, erythema and induration) and could be considered to be inherent to the injection technique. The technical and safety advantages of the Mini-Imojet(R)/Imule(R) system, compared to sterilizable, standard disposable or autodestruct syringes and to classical multi-dose vial jet-injectors, reinforces the interest of this new injection technique for collective immunizations. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:449 / 458
页数:10
相关论文
共 28 条
  • [1] AJJAN N, 1981, P 6 INT C TET LYON 3, P185
  • [2] AYLWARD B, 1995, B WORLD HEALTH ORGAN, V73, P531
  • [3] VIRUS TRANSMISSION BY SUBCUTANEOUS JET INJECTION
    BRINK, PRG
    VANLOON, AM
    TROMMELEN, JCM
    GRIBNAU, FWJ
    SMALENOVAKOVA, IRO
    [J]. JOURNAL OF MEDICAL MICROBIOLOGY, 1985, 20 (03) : 393 - 397
  • [4] Centers for Disease Control (CDC), 1986, MMWR Morb Mortal Wkly Rep, V35, P373
  • [5] IMPACT OF HAEMOPHILUS-INFLUENZAE TYPE-B POLYSACCHARIDE-TETANUS PROTEIN CONJUGATE VACCINE ON RESPONSES TO CONCURRENTLY ADMINISTERED DIPHTHERIA-TETANUS-PERTUSSIS VACCINE
    CLEMENS, JD
    FERRECCIO, C
    LEVINE, MM
    HORWITZ, I
    RAO, MR
    EDWARDS, KM
    FRITZELL, B
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1992, 267 (05): : 673 - 678
  • [6] DAGNAN S, 1994, P 4 INT SEM IMM AFR, P340
  • [7] DASTUR FD, 1981, LANCET, V2, P219
  • [8] Drucker J, 1986, Dev Biol Stand, V65, P145
  • [9] SIGNIFICANCE TESTING TO ESTABLISH EQUIVALENCE BETWEEN TREATMENTS, WITH SPECIAL REFERENCE TO DATA IN FORM OF 2 X 2 TABLES
    DUNNETT, CW
    GENT, M
    [J]. BIOMETRICS, 1977, 33 (04) : 593 - 602
  • [10] EDWARDS EA, 1974, B WORLD HEALTH ORGAN, V51, P501