Zeolite-magnetite composites to remove Hg2+ from water

被引:5
|
作者
Andrade, Angela Leao [1 ]
Duarte Cavalcante, Luis Carlos [2 ]
Fabris, Jose Domingos [3 ,4 ]
Pereira, Marcio Cesar [5 ]
Ardisson, Jose Domingos [6 ]
Pizarro, Carmen [7 ]
机构
[1] Fed Univ Ouro Preto UFOP, Dept Chem, BR-35400000 Ouro Preto, MG, Brazil
[2] Fed Univ Piaui UFPI, Ctr Nat Sci, BR-64049550 Teresina, PI, Brazil
[3] Fed Univ Minas Gerais UFMG, Dept Chem, BR-31270901 Belo Horizonte, MG, Brazil
[4] Fed Univ Uberlandia UFU, Inst Chem, BR-38400902 Uberlandia, MG, Brazil
[5] Fed Univ Jequitinhonha & Mucuri Valleys UFVJM, Inst Sci Engn & Technol, BR-39803371 Teofilo Otoni, MG, Brazil
[6] Ctr Dev Nucl Tecnol CDTN, Lab Appl Phys, BR-31270901 Belo Horizonte, MG, Brazil
[7] Univ Santiago, Fac Chem & Biol, Chile USACH, Santiago, Chile
来源
HYPERFINE INTERACTIONS | 2019年 / 240卷 / 01期
关键词
Zeolite-magnetite composites; Mercury; Environment contaminant; MERCURY REMOVAL; NANOPARTICLES; GOLD; SPECIATION; SILVER; IRON;
D O I
10.1007/s10751-019-1624-5
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
It is reported an innovative though still exploratory study devoted to characterizing their structure and evaluating the response of zeolite-magnetite composites as adsorbing materials to remove Hg2+ from water. The zeolite material collected from a sampling site in Parral, Chile, was identified and structurally characterized as containing mordenite with crystallographic orthorhombic unit cell dimensions a=18.060(1) angstrom; b=20.429(2) angstrom and c=7.5091(7) angstrom. From Mossbauer data, two paramagnetic ferric iron sites occur in its structure. This zeolite, a sample of synthetic magnetite and their two-component composites were used as adsorbers to sequester Hg2+ dissolved in water. The adsorption rate was found to reach a steady state of nearly constant Hg concentrations corresponding to 26.2; 22.1; 20.6; 17.4 and 16.7mg Hg per g adsorber, between 24h and 72h reaction, for the samples zeolite only, for the composites zeolite:magnetite mass ratio 10:1; 5:1; 1:1 and for the magnetite only, respectively. These corresponding maximum adsorption capacities reduced the initial concentration of Hg2+ in water from 700mgL(-1) to an equilibrium concentration of 0; 110; 150; 240 and 250mgL(-1), respectively. Although the composites showed a lower adsorption capacity of Hg than did the sole zeolite (zeol sample), the composites contained magnetic particles, which allow the adsorbing systems to be readily removed from the aqueous medium, with a magnetic field. These combined characteristic point to the remarkable potential of such materials, particularly the mag-zeol-2, to be used to remediate natural bodies of water contaminated with Hg.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Carbon material–immobilized ionic liquids were applied on absorption of Hg2+ from water phase
    Lihan Sun
    Mengru Wang
    Wei Li
    Sha Luo
    Yan Wu
    Chunhui Ma
    Shouxin Liu
    Environmental Science and Pollution Research, 2020, 27 : 26882 - 26904
  • [42] A colorimetric probe for dual sensing of Hg2+ and Cu2+ ions in water
    Sie, Yi-Wun
    Li, Chia-Lin
    Wan, Chin-Feng
    Chen, Jie-Hong
    Hu, Ching-Han
    Yan, Hongbin
    Wu, An-Tai
    INORGANICA CHIMICA ACTA, 2017, 467 : 325 - 329
  • [43] The kinetics of mercury nucleation from Hg2+2 and Hg2+ solutions on vitreous carbon electrodes
    Serruya, A
    Mostany, J
    Scharifker, BR
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 464 (01): : 39 - 47
  • [44] ZnS Nanoparticle Gels for Remediation of Pb2+ and Hg2+ Polluted Water
    Pala, Irina R.
    Brock, Stephanie L.
    ACS APPLIED MATERIALS & INTERFACES, 2012, 4 (04) : 2160 - 2167
  • [45] Fabrication of AO/LDH fluorescence composite and its detection of Hg2+ in water
    Meng Liu
    Guocheng Lv
    Lefu Mei
    Yanke Wei
    Jieyuan Liu
    Zhaohui Li
    Libing Liao
    Scientific Reports, 7
  • [46] Zeolite/magnetite composites as catalysts on the Synthesis of Methyl Esters (MES) from cooking oil
    Sriatun
    Darmawan, Adi
    Sriyanti
    Cahyani, Wuri
    Widyandari, Hendri
    7TH INTERNATIONAL SEMINAR ON NEW PARADIGM AND INNOVATION ON NATURAL SCIENCE AND ITS APPLICATION, 2018, 1025
  • [47] Zeolite/magnetite composites as catalysts on the Synthesis of Methyl Esters (MES) from cooking oil
    Sriatun
    Darmawan, Adi
    Sriyanti
    Cahyani, Wuri
    Widyandari, Hendri
    7TH INTERNATIONAL SEMINAR ON NEW PARADIGM AND INNOVATION ON NATURAL SCIENCE AND ITS APPLICATION, 2018, 1025
  • [48] The Research on Trace Amount Hg2+ in Water Determined by Restraining Chemiluminescence Method
    Wu Wan-e
    Shuai Ling
    Du Yong
    2011 INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SYSTEMS SCIENCE AND ENGINEERING (ICESSE 2011), VOL 3, 2011, : 115 - 120
  • [49] Magnetically recoverable fluorescence chemosensor for the adsorption and selective detection of Hg2+ in water
    Lv, Qiang
    Li, Gang
    Cheng, Zhuhong
    Lu, Hong
    Gao, Xiaoxia
    ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS, 2014, 16 (01) : 116 - 123
  • [50] Toxicity effect of Hg2+ and Cr (VI) on algae growth in eutrophic water
    Bi, Dongsu
    Chen, Zhenmin
    2008 PROCEEDINGS OF INFORMATION TECHNOLOGY AND ENVIRONMENTAL SYSTEM SCIENCES: ITESS 2008, VOL 4, 2008, : 758 - 761