Biomechanical Evaluation of the Modified Cannulated Screws Fixation of Unstable Femoral Neck Fracture with Comminuted Posteromedial Cortex

被引:12
|
作者
Liu, Jingwen [1 ]
Zhang, Baokun [1 ]
Yin, Bohao [1 ]
Chen, Hongchi [1 ]
Sun, Hui [1 ]
Zhang, Wei [1 ]
机构
[1] Shanghai Jiao Tong Univ, Affiliated Peoples Hosp 6, Dept Orthoped Surg, Shanghai 200233, Peoples R China
关键词
DYNAMIC HIP SCREW; INTRACAPSULAR FRACTURES; POSTERIOR COMMINUTION; INTERNAL-FIXATION; CONFIGURATION; MULTICENTER; PARALLEL; IMPLANT; FEMUR;
D O I
10.1155/2019/2584151
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose. To verify the biomechanical importance with respect to the integrity of posteromedial cortex of femoral neck fracture (FNF) and demonstrate whether the modified fixation of cannulated screws (CSs) could increase the biomechanical strength. Methods. A total of 24 left artificial femurs were randomly divided into three groups. The osteotomy was made in the center of the femoral neck at a 20 degrees angle to the shaft axial. The posteromedial cortices of femoral neck were removed in groups B and C. In group A, 8 femurs with intact posteromedial cortex were fixed with three parallel partial thread screws (PTSs), forming a standard triangle. In group B, the femurs were stabilized with the same fixation of CSs like group A. In group C, two inferior PTSs were replaced by two fully thread screws (FTSs). Results. The lower A-P and axial stiffness and load to failure along with higher axial displacement were found in group B compared with group A (p <= 0.001 for all). Between groups B and C, the modified fixation of CSs increased A-P and axial stiffness and load to failure and reduced the axial displacement (p <= 0.001 for all). Conclusions. We verified that the comminuted posteromedial cortex affected the biomechanical strength adversely and resulted in higher displacement. The modified fixation of CSs characterized by two inferior FTSs could improve the biomechanical performance and buttress the femoral head fragment better.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] In Vitro Biomechanical Study of Femoral Neck Fracture Fixation with Two or Three Cannulated Screws in Dogs
    Caldeira, Fatima Maria C.
    Rahal, Sheila C.
    Cassanego, Guilherme R.
    Ribeiro, Celso R.
    Serrato, Sergio A. A.
    Mele, Carlos E.
    Masseran, Paulo
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2024,
  • [2] Ordinary Cannulated Compression Screws or Headless Cannulated Compression Screws? A Synthetic Bone Biomechanical Research in the Internal Fixation of Vertical Femoral Neck Fracture
    Zhang, Baokun
    Liu, Jingwen
    Zhang, Wei
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [3] Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture
    Zheng Wang
    Yong Yang
    Gangning Feng
    Haohui Guo
    Zhirong Chen
    Yaogeng Chen
    Qunhua Jin
    BioMedical Engineering OnLine, 21
  • [4] Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture
    Wang, Zheng
    Yang, Yong
    Feng, Gangning
    Guo, Haohui
    Chen, Zhirong
    Chen, Yaogeng
    Jin, Qunhua
    BIOMEDICAL ENGINEERING ONLINE, 2022, 21 (01)
  • [5] Biomechanical Research of Three Parallel Cannulated Compression Screws in Oblique Triangle Configuration for Fixation of Femoral Neck Unstable Fractures
    Zhang, Ru-Yi
    Zhang, Wu-Peng
    Yang, Guang-Min
    Wang, Dao-Feng
    Su, Peng
    Zhang, Yi
    Nie, Shao-Bo
    Li, Jia
    Zhao, Zhe
    Li, Jian-Tao
    Zhang, Li-Cheng
    Tang, Pei-Fu
    ORTHOPAEDIC SURGERY, 2024, 16 (04) : 953 - 964
  • [6] Biomechanical Evaluation of the Femoral Neck System in Unstable Pauwels III Femoral Neck Fractures: A Comparison with the Dynamic Hip Screw and Cannulated Screws
    Stoffel, Karl
    Zderic, Ivan
    Gras, Florian
    Sommer, Christoph
    Eberli, Ursula
    Mueller, David
    Oswald, Martin
    Gueorguiev, Boyko
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (03) : 131 - 137
  • [7] Optimum Configuration of Cannulated Compression Screws for the Fixation of Unstable Femoral Neck Fractures: Finite Element Analysis Evaluation
    Li, Jiantao
    Wang, Menglin
    Zhou, Jianfeng
    Han, Lin
    Zhang, Hao
    Li, Chen
    Li, Lianting
    Hao, Ming
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [8] A Comparative Biomechanical Analysis of Fixation Devices for Unstable Femoral Neck Fractures: The Intertan Versus Cannulated Screws or a Dynamic Hip Screw
    Rupprecht, Martin
    Grossterlinden, Lars
    Ruecker, Andreas H.
    de Oliveira, Alexander Novo
    Sellenschloh, Kay
    Nuechtern, Jakob
    Pueschel, Klaus
    Morlock, Michael
    Rueger, Johannes Maria
    Lehmann, Wolfgang
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 71 (03): : 625 - 634
  • [9] Biomechanical evaluation of the expansive cannulated screw for fixation of femoral neck fractures
    Zhang, Yang
    Tian, Li
    Yan, Yabo
    Sang, Hongxun
    Ma, Zhensheng
    Jie, Qiang
    Lei, Wei
    Wu, Zixiang
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (11): : 1372 - 1376
  • [10] Dynamic Hip and Cannulated Screws in Fixation of Adults Femoral Neck Fracture: A Comparative Study
    Al-Kelabi, Adnan Essa
    Mahmoud, Mustafa Shakir
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2018, 7 (03): : 135 - 142