Flow-injection and sequential injection determination of hydroxypurines on an electrode modified with mixed-valence ruthenium and iridium oxides

被引:5
作者
Shaidarova, L. G. [1 ]
Chelnokova, I. A. [1 ]
Makhmutova, G. F. [1 ]
Degteva, M. A. [1 ]
Gedmina, A. V. [1 ]
Budnikov, H. C. [1 ]
机构
[1] Kazan Fed Univ, Butlerov Inst Chem, Kazan 420008, Russia
基金
俄罗斯基础研究基金会;
关键词
chemically modified electrodes; mixed-valence ruthenium and iridium oxides; electrooxidation of hydroxypurines; flow injection analysis; sequential injection analysis; URIC-ACID; ASCORBIC-ACID; ELECTROCATALYTIC OXIDATION; XANTHINE; HYPOXANTHINE; BIOSENSORS; ALLANTOIN; SENSOR; SIGNAL;
D O I
10.1134/S106193481409010X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mixed-valence ruthenium (RuO (x) ) and iridium (IrO (x) ) oxides and composites on their basis (RuO (x) -IrO (x) or IrO (x) -RuO (x) ) electrodeposited onto the surface of a glassy carbon electrode exhibit a catalytic activity in the electrooxidation of uric acid, xanthine, and hypoxanthine. The transition from metal oxides to composites of two mixed-valence metal oxides leads to an increase in the catalytic effect of the oxidation of hydroxypurines. The IrO (x) -RuO (x) composite demonstrated the highest catalytic activity. Procedures for the amperometric detection of hydroxypurines on this composite electrode under the conditions of flow-injection analysis (FIA) and sequential injection analysis are proposed. A linear dependence of an analytical signal on the analyte concentration is observed in the range 1 x 10(-6) to 5 x 10(-3) M for uric acid and xanthine and 5 x 10(-7) to 5 x 10(-3) M for hypoxanthine under FIA conditions and from 5 x 10(-7) to 5 x 10(-3) M for uric acid and xanthine and 5 x 10(-9) to 5 x 10(-3) M for hypoxanthine in sequential injection analysis. Under FIA conditions, the sensitivity, rapidity, and performance of the analysis increase compared to the stationary conditions. The advantages of sequential injection analysis over FIA include a lower consumption of the supporting electrolyte; the absence of pumps and connections; and an increase in sensitivity, reproducibility, and rapidity.
引用
收藏
页码:864 / 874
页数:11
相关论文
共 34 条
[1]   Determination of uric acid by voltammetry and coulometric titration [J].
Abdullin, IF ;
Bakanina, YN ;
Turova, EN ;
Budnikov, GK .
JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 56 (05) :453-456
[2]   Amperometric xanthine biosensors based on electrodeposition of platinum on polyvinylferrocenium coated Pt electrode [J].
Bas, Salih Zeld ;
Gulce, Handan ;
Yildiz, Salih .
JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 2011, 72 (3-4) :282-288
[3]  
Budnikov G.K., 2010, Modified Electrodes for Voltammetry in Chemistry, Biology, and Medicine
[4]  
Budnikov G.K., 2003, Fundamentals of Modern Electrochemical Analysis
[5]   Amperometric detection of uric acid and hypoxanthine with Xanthine oxidase immobilized and carbon based screen-printed electrode. Application for fish freshness determination [J].
Carsol, MA ;
Volpe, G ;
Mascini, M .
TALANTA, 1997, 44 (11) :2151-2159
[6]   Simultaneous determination of allantoin, hypoxanthine, xanthine, and uric acid in serum/plasma by CE [J].
Causse, Elizabeth ;
Pradelles, Aude ;
Dirat, Beatrice ;
Negre-Salvayre, Anne ;
Salvayre, Robert ;
Couderc, Francois .
ELECTROPHORESIS, 2007, 28 (03) :381-387
[7]   Quantification of allantoin, uric acid, xanthine and hypoxanthine in ovine urine by high-performance liquid chromatography and photodiode array detection [J].
Czauderna, M ;
Kowalczyk, J .
JOURNAL OF CHROMATOGRAPHY B, 2000, 744 (01) :129-138
[9]   Electrochemical tagging of urate: developing new redox probes [J].
Dutt, JSN ;
Cardosi, MF ;
Davis, J .
ANALYST, 2003, 128 (07) :811-813
[10]   Electrocatalytic oxidation of uric acid at an electrodeposited redox polymer film-modified gold electrode [J].
Fei, JJ ;
Wu, KB ;
Wu, YH ;
Hu, SS .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2004, 8 (05) :316-321