Utility integration of PV-wind-fuel cell hybrid distributed generation systems under variable load demands

被引:54
作者
Eid, Ahmad [1 ]
机构
[1] Aswan Univ, Fac Engn, Dept Elect Engn, Aswan 81542, Egypt
关键词
Distributed generation; Wind; Photovoltaic; Fuel cell; Field-oriented control; Bidirectional converter; POWER-GENERATION; MODEL; COMPENSATION; CONVERTER;
D O I
10.1016/j.ijepes.2014.05.020
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents modeling, control and performance of a DC micro-grid connected to the utility under variable load demand and different environmental conditions. This micro-grid consists of 60 kW wind turbine (WT) energy conversion system, 40 kW photovoltaic (PV) panel and 40 kW fuel cell (FC) module, in addition to, DC and AC loads. The WT energy conversion system is controlled by the indirect field orientation control (FOC) method to extract maximum power from the wind. The PV module is controlled to generate the available maximum power using P&O MPPT control considering environmental conditions. The fuel cell, with a current controlled DC/DC boost converter, supplies power only when the load demand exceeds the total power of the WT and PV systems. A bidirectional 6-pulse PWM converter connects the micro-grid to utility using the natural frame control (NFC) technique. It controls the DC bus voltage, power and reactive power transfer to/from the utility according to the available power from the DG units and the total load demand. The various control algorithms are presented to harness the maximum power from the renewable energy sources at different operating modes. In addition, voltage stability and smooth power transfer between the micro-grid and utility are maintained. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:689 / 699
页数:11
相关论文
共 27 条
[1]  
Abad G., 2011, DOUBLY FED INDUCTION, V85
[2]  
Altas I. H., 2007, IEEE International Conference on Clean Electrical Power, 2007. ICCEP '07, P341
[3]  
Anaya-Lara O., 2009, Wind Energy Generation : Modeling and Control
[4]   Modelling and simulation of the steady-state and dynamic behaviour of a PEM fuel cell [J].
Asl, S. M. Sharifi ;
Rowshanzamir, S. ;
Eikani, M. H. .
ENERGY, 2010, 35 (04) :1633-1646
[5]   Overview of control and grid synchronization for distributed power generation systems [J].
Blaabjerg, Frede ;
Teodorescu, Remus ;
Liserre, Marco ;
Timbus, Adrian V. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) :1398-1409
[6]   A MATLAB-Simulink-Based PV Module Model and Its Application Under Conditions of Nonuniform Irradiance [J].
Ding, Kun ;
Bian, XinGao ;
Liu, HaiHao ;
Peng, Tao .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2012, 27 (04) :864-872
[7]   Flexible Active Compensator Control for Variable Compensation Objectives [J].
Ginn, Herbert L., III ;
Chen, Guangda .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (06) :2931-2941
[8]  
Goel Puneet K., 2009, 2009 International Conference on Power Electronics and Drive Systems (PEDS 2009), P55, DOI 10.1109/PEDS.2009.5385678
[9]   A Flexible Harmonic Control Approach Through Voltage-Controlled DG-Grid Interfacing Converters [J].
He, Jinwei ;
Li, Yun Wei ;
Munir, Md Shirajum .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (01) :444-455
[10]   Fuzzy logic enhanced speed control of an indirect field-oriented induction machine drive [J].
Heber, B ;
Xu, LY ;
Tang, YF .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1997, 12 (05) :772-778