Cloud point extraction, preconcentration and spectrophotometric determination of trace amount of manganese(II) in water and food samples

被引:33
|
作者
Gouda, Ayman A. [1 ,2 ]
机构
[1] Zagazig Univ, Fac Sci, Dept Chem, Zagazig 44519, Egypt
[2] Umm AL Qura Univ, Fac Publ Hlth & Informat, Mecca, Saudi Arabia
关键词
Cloud point extraction; Manganese(II) determination; Spectrophotometry; Quinalizarin; Water samples; Food samples; ATOMIC-ABSORPTION-SPECTROMETRY; SOLID-PHASE EXTRACTION; OPTICAL-EMISSION SPECTROMETRY; SIZE-EXCLUSION CHROMATOGRAPHY; METAL-IONS; ENVIRONMENTAL-SAMPLES; MULTIELEMENT COPRECIPITATION; MASS SPECTROMETRY; NATURAL-WATER; TEA INFUSIONS;
D O I
10.1016/j.saa.2014.04.075
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A new cloud point extraction (CPE) process using the nonionic surfactant Triton X-114 to extract manganese(II) from aqueous solution was investigated. The method is based on the complexation reaction of manganese(II) with 1,2,5,8-tetrahydroxyanthracene-9,10-dione (quinalizarin) in the presence of borate buffer at pH 8.5 and micelle-mediated extraction of the complex. The enriched analyte in the surfactant-rich phase was determined by spectrophotometry at 528 nm. The optimal extraction and reaction conditions (e.g. pH, reagent and surfactant concentrations, temperature and centrifugation times) were evaluated and optimized. Under the optimized experimental conditions, the analytical characteristics of the method (e.g., limit of detection (LOD), linear range, preconcentration and improvement factors) were obtained. The proposed CPE method showed linear calibration within the range 5.0-200 ng mL(-1) of manganese(II) and the limit of detection of the method was 0.8 ng mL(-1) with an preconcentration factor of 50 when 25 mL of sample solution was preconcentrated to 0.5 mL. The relative standard deviation (RSD) and relative error were found to be 1.35% and 1.42%, respectively (C-Mn(II)= 150 ng mL(-1) = 6) for pure standard solutions. The interference effect of some cations and anions was also studied. In the presence of foreign ions, no significant interference was observed. The method was applied to the determination of manganese(II) in water and food samples with a recovery for the spiked samples in the range of 95.87-102.5%. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:138 / 144
页数:7
相关论文
共 50 条
  • [31] Development of a cloud-point extraction method for determination of trace amounts of copper(II) in water samples
    Mahdieh Koorepazan Moftakhar
    Mohammad Reza Yaftian
    Abbasali Zamani
    Journal of Analytical Chemistry, 2015, 70 : 1085 - 1091
  • [32] Development of a Cloud-Point Extraction Method for Determination of Trace Amounts of Copper(II) in Water Samples
    Moftakhar, Mahdieh Koorepazan
    Yaftian, Mohammad Reza
    Zamani, Abbasali
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (09) : 1085 - 1091
  • [33] An on-line cloud point extraction system for flame atomic absorption spectrometric determination of trace manganese in food samples
    Lemos, Valfredo Azevedo
    David, Graciete Teixeira
    MICROCHEMICAL JOURNAL, 2010, 94 (01) : 42 - 47
  • [34] Determination of Trace Iron in Water and Wine Samples by Spectrophotometry with Cloud Point Extraction
    Chang Zheng
    Yan Hongtao
    Huang Jiajian
    ACTA CHIMICA SINICA, 2010, 68 (07) : 717 - 721
  • [35] Determination of Trace Copper(II) in Food Samples by Flame Atomic Absorption Spectrometry After Cloud Point Extraction
    Xiang Guoqiang
    Wen Shengping
    Jiang Xiuming
    Liu Xing
    He Lijun
    IRANIAN JOURNAL OF CHEMISTRY & CHEMICAL ENGINEERING-INTERNATIONAL ENGLISH EDITION, 2011, 30 (03): : 101 - 107
  • [36] A New Ultrasonic Thermostatic-Assisted Cloud Point Extraction/Spectrophotometric Method for the Preconcentration and Determination of Bisphenol A in Food, Milk, and Water Samples in Contact with Plastic Products
    Yildirim, Emre
    Gurkan, Ramazan
    Altunay, Nail
    FOOD ANALYTICAL METHODS, 2017, 10 (06) : 1765 - 1776
  • [37] A New Ultrasonic Thermostatic-Assisted Cloud Point Extraction/Spectrophotometric Method for the Preconcentration and Determination of Bisphenol A in Food, Milk, and Water Samples in Contact with Plastic Products
    Emre Yıldırım
    Ramazan Gürkan
    Nail Altunay
    Food Analytical Methods, 2017, 10 : 1765 - 1776
  • [38] Determination of trace mercury by cloud point extraction preconcentration coupled with spectrophotometry
    Sohrabi, Mahmoud Reza
    Farokhi, Elham
    Adnani, Atena
    Ziaian, Mona
    Journal of Applied Sciences, 2007, 7 (20) : 3123 - 3126
  • [39] Ultrasound assisted extraction and spectrophotometric determination of trace selenium in water, food and vegetable samples
    Altunay, Nail
    Gurkan, Ramazan
    Gunes, Murat
    ANALYTICAL METHODS, 2016, 8 (46) : 8208 - 8218
  • [40] Determination of trace aluminum in biological and water samples by cloud point extraction preconcentration and graphite furnace atomic absorption spectrometry detection
    Sang, Hongbo
    Liang, Pei
    Du, Dan
    JOURNAL OF HAZARDOUS MATERIALS, 2008, 154 (1-3) : 1127 - 1132