Dependency of dose response of five charge-coupled device-based digital intra-oral radiographic systems on tube voltage

被引:3
作者
Nishikawa, K [1 ]
Shibuya, H [1 ]
Wakoh, M [1 ]
Kuoryanagi, K [1 ]
机构
[1] Tokyo Dent Coll, Dept Oral & Maxillofacial Radiol, Mihama Ku, Chiba 2618502, Japan
关键词
radiography; dental; digital imaging; technology; radiologic; dose-response relationship; radiation;
D O I
10.1038/sj.dmfr.4600484
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To compare the dependency of dose response of five CCD-based digital intra-oral radiographic systems on tube voltage. Methods: Characteristic curves for Sens-A-Ray (old and new generations; Regam Medical Systems, Sundsvall, Sweden), Computed Dental Radiography (Schick Technologies, Long Island City, NY, USA), CompuRay (Yoshida, Tokyo, Japan), and VIXA (Dentsply/Gendex, Des Plaines, IL, USA) were generated between 60 and 90 kVp at intervals of 10 kVp and corrected by subtraction of dark current. Their sensitivities were compared. Results: The sensitivity of the old generation Sens-A-Ray decreased with increase in tube voltage whereas in the other systems it increased. Conclusion: In the newer systems using a rare earth intensifying screen as a scintillator, the sensitivity increases with increase in tube voltage, thus reducing the radiation dose to the patient.
引用
收藏
页码:364 / 367
页数:4
相关论文
共 13 条
[1]  
[Anonymous], 1984, TXB DENT RADIOLOGY
[2]  
Farman A G, 1995, Quintessence Int, V26, P399
[3]   Sensitometric response of the Sens-A-Ray, a charge-coupled imaging device, to changes in beam energy [J].
Goshima, T ;
Goshima, Y ;
Scarfe, WC ;
Farman, AG .
DENTOMAXILLOFACIAL RADIOLOGY, 1996, 25 (01) :17-18
[4]   SENS-A-RAY CHARACTERISTICS WITH VARIATIONS IN-BEAM QUALITY [J].
HARADA, T ;
NISHIKAWA, K ;
SHIBUYA, H ;
HAYAKAWA, Y ;
KUROYANAGI, K .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1995, 80 (01) :120-123
[5]   Optimum exposure ranges for computed dental radiography [J].
Hayakawa, Y ;
Farman, AG ;
Scarfe, WC ;
Kuroyanagi, K ;
Rumack, PM ;
Schick, DB .
DENTOMAXILLOFACIAL RADIOLOGY, 1996, 25 (02) :71-75
[6]  
HAYAKAWA Y, 1995, ORAL RADIOL, V11, P31
[7]  
JOHNS HE, 1977, PHYSICS RADIOLOGY
[8]  
Kapa S F, 1990, Dentomaxillofac Radiol, V19, P67
[9]   THE REDUCTION IN RADIATION-DOSE FOR INTRAORAL RADIOGRAPHS BY THE USE OF THIN K-EDGE FILTERS [J].
MACDONALDJANKOWSKI, DS ;
LAWINSKI, CP .
BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (762) :524-528
[10]   SAMARIUM FILTERS FOR DENTAL RADIOGRAPHY [J].
RICHARDS, AG ;
BARBOR, GL ;
BADER, JD ;
HALE, JD .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1970, 29 (05) :704-&