Development of a stable cholesterol biosensor based on multi-walled carbon nanotubes-gold nanoparticles composite covered with a layer of chitosan-room-temperature ionic liquid network

被引:134
作者
Gopalan, Anantha Iyengar [1 ,2 ]
Lee, Kwang-Pill [1 ,2 ]
Ragupathy, Dhanusuraman [1 ]
机构
[1] Kyungpook Natl Univ, Dept Chem, Grad Sch, Taegu 702701, South Korea
[2] Nano Pract Applicat Ctr, Taegu 704801, South Korea
关键词
Cholesterol; Gold nanoparticles; Ionic liquid; Chitosan; Multi-wall carbon nanotubes; Amperometry; GLUCOSE-OXIDASE; DIRECT ELECTROCHEMISTRY; AMPEROMETRIC BIOSENSOR; PRUSSIAN BLUE; IMMOBILIZATION; POLYANILINE; FILM; POLYPYRROLE; PEROXIDASE; ENZYME;
D O I
10.1016/j.bios.2008.11.034
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel amperometric biosensor was fabricated based on the immobilization of cholesterol oxidase (ChOx) into a cross-linked matrix of chitosan (Chi)-room-temperature ionic liquid (IL) (1-butyl-3-methylimidazolium tetrafluoroborate). Initially, the surface of bare electrode (indium tin oxide coated glass) was modified with the electrodeposition of Au particles onto thiol (-SH) functionalized multi-walled carbon nanotubes (MWNTs). The biosensor electrode is designated as MWNT(SH)-Au/Chi-IL/ChOx. Scanning electron microscopy image of MWNT(SH)-Au/Chi-IL/ChOx reveals that Chi-IL exists as the interconnected wires covering the Au particles on the surface of MWNT(SH)-Au. Cyclic voltammetry and chronoamperometry were used for the electrochemical determination of cholesterol at the biosensor electrode, MWNT(SH)-Au/Chi-IL/ChOx. The presence of Au particles in the matrix of CNTs provides an environment for the enhanced electrocatalytic activities. The MWNT(SH)-Au/Chi-IL/ChOx biosensor exhibited a linear response to cholesterol in the concentration range of 0.5-5 mM with a correlation coefficient of 0.998, good sensitivity (200 mu A M-1), a low response time (similar to 7 s), repeatability (R.S.D value of 1.9%) and long term stability (20 days with a decrease of 5% response). The synergistic influence of MWNT(SH), Au particles, Chi and IL contributes to the excellent performance for the biosensor. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:2211 / 2217
页数:7
相关论文
共 43 条
[1]   Recent advances in cholesterol biosensor [J].
Arya, Sunil K. ;
Datta, Monika ;
Malhotra, Bansi D. .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (07) :1083-1100
[2]   Cholesterol biosensor based on N-(2-aminoethyl)-3-aminopropyl-trimethoxysilane self-assembled monolayer [J].
Arya, Sunil K. ;
Prusty, Arun K. ;
Singh, S. P. ;
Solanki, Pratima R. ;
Pandey, Manoj K. ;
Datta, Monika ;
Malhotra, Bansi D. .
ANALYTICAL BIOCHEMISTRY, 2007, 363 (02) :210-218
[3]   Amperometric determination of cholesterol in serum using a biosensor of cholesterol oxidase contained within a polypyrrole-hydrogel membrane [J].
Brahim, S ;
Narinesingh, D ;
Guiseppi-Elie, A .
ANALYTICA CHIMICA ACTA, 2001, 448 (1-2) :27-36
[4]   Amperometric third-generation hydrogen peroxide biosensor based on the immobilization of hemoglobin on multiwall carbon nanotubes and gold colloidal nanoparticles [J].
Chen, Shihong ;
Yuan, Ruo ;
Chai, Yaqin ;
Zhang, Lingyan ;
Wang, Na ;
Li, Xuelian .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (07) :1268-1274
[5]   Identification of inductive behavior for polyaniline via electrochemical impedance spectroscopy [J].
Chen, WC ;
Wen, TC ;
Hu, CC ;
Gopalan, A .
ELECTROCHIMICA ACTA, 2002, 47 (08) :1305-1315
[6]   Spontaneous reduction of metal ions on the sidewalls of carbon nanotubes [J].
Choi, HC ;
Shim, M ;
Bangsaruntip, S ;
Dai, HJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (31) :9058-9059
[7]   Direct electrochemistry of glucose oxidase and biosensing for glucose based on boron-doped carbon nanotubes modified electrode [J].
Deng, Chunyan ;
Chen, Jinhua ;
Chen, Xiaoli ;
Mao, Chunhui ;
Nie, Lihua ;
Yao, Shouzhuo .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (08) :1272-1277
[8]   Cholesterol biosensor based on electrophoretically deposited conducting polymer film derived from nano-structured polyaniline colloidal suspension [J].
Dhand, Chetna ;
Singh, S. P. ;
Arya, Sunil K. ;
Datta, Blonika ;
Malhotra, B. D. .
ANALYTICA CHIMICA ACTA, 2007, 602 (02) :244-251
[9]   Electrochemical determination of dopamine and ascorbic acid at a novel gold nanoparticles distributed poly(4-aminothiophenol) modified electrode [J].
Gopalan, Anantha Iyengar ;
Lee, Kwang-Pill ;
Manesh, Kalayil Manian ;
Santhosh, Padmanabhan ;
Kim, Jun Heon ;
Kang, Jae Soo .
TALANTA, 2007, 71 (04) :1774-1781
[10]   Carbon nanotubes-based amperometric cholesterol biosensor fabricated through layer-by-layer technique [J].
Guo, ML ;
Chen, JH ;
Li, J ;
Nie, LH ;
Yao, SZ .