A novel amperometric alcohol biosensor developed in a 3rd generation bioelectrode platform using peroxidase coupled ferrocene activated alcohol oxidase as biorecognition system

被引:38
作者
Chinnadayyala, Somasekhar R. [1 ]
Kakoti, Ankana [1 ]
Santhosh, Mallesh [1 ]
Goswami, Pranab [1 ]
机构
[1] Indian Inst Technol Guwahati, Dept Biotechnol, Gauhati 781039, Assam, India
关键词
Biosensor; Alcohol; Ferrocene; Alcohol oxidase; Horseradish peroxidase; Direct electron transfer; DIRECT ELECTROCHEMISTRY; CARBON NANOTUBES; DEHYDROGENASE; ETHANOL; FILM; PURIFICATION; RECOGNITION; ELECTRODES; GLUCOSE;
D O I
10.1016/j.bios.2013.12.005
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Alcohol oxidase (AOx) with a two-fold increase in efficiency (K-cat/K-m) was achieved by physical entrapment of the activator ferrocene in the protein matrix through a simple microwave based partial unfolding technique and was used to develop a 3rd generation biosensor for improved detection of alcohol in liquid samples. The ferrocene molecules were stably entrapped in the AOx protein matrix in a molar ratio of similar to 3:1 through electrostatic interaction with the Trp residues involved in the functional activity of the enzyme as demonstrated by advanced analytical techniques. The sensor was fabricated by immobilizing ferrocene entrapped alcohol oxidase (FcAOx) and sol-gel chitosan film coated horseradish peroxidase (HRP) on a multi-walled carbon nanotube (MWCNT) modified glassy carbon electrode through layer-by-layer technique. The bioelectrode reactions involved the formation of H2O2 by FcAOx biocatalysis of substrate alcohol followed by HRP-catalyzed reduction of the liberated H2O2 through MWCNT supported direct electron transfer mechanism. The amperometric biosensor exhibited a linear response to alcohol in the range of 5.0 x 10(-6) to 30 x 10(-4) mol L-1 with a detection limit of 2.3 x 10(-6) mol L-1, and a sensitivity of 150 mu A mM(-1) cm(-2). The biosensor response was steady for 28 successive measurements completed in a period of 5 h and retained similar to 90% of the original response even after four weeks when stored at 4 degrees C. The biosensor was successfully applied for the determination of alcohol in commercial samples and its performance was validated by comparing with the data obtained by GC analyses of the samples. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:120 / 126
页数:7
相关论文
共 37 条
[1]   Role of carbon nanotubes in electroanalytical chemistry -: A review [J].
Agui, Lourdes ;
Yanez-Sedeno, Paloma ;
Pingarron, Jose M. .
ANALYTICA CHIMICA ACTA, 2008, 622 (1-2) :11-47
[2]   Covalent layer-by-layer type modification of electrodes using ferrocene derivatives and crosslinkers [J].
Asaftei, S ;
Walder, L .
ELECTROCHIMICA ACTA, 2004, 49 (26) :4679-4685
[3]   Ethanol biosensors based on alcohol oxidase [J].
Azevedo, AM ;
Prazeres, DMF ;
Cabral, JMS ;
Fonseca, LP .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (02) :235-247
[4]   Molecular recognition of protein-ligand complexes: Applications to drug design [J].
Babine, RE ;
Bender, SL .
CHEMICAL REVIEWS, 1997, 97 (05) :1359-1472
[5]   Enzymatic biofuel cells for Implantable and microscale devices [J].
Barton, SC ;
Gallaway, J ;
Atanassov, P .
CHEMICAL REVIEWS, 2004, 104 (10) :4867-4886
[6]   THIN-FILM BIENZYME AMPEROMETRIC BIOSENSORS BASED ON POLYMERIC REDOX MEDIATORS WITH ELECTROSTATIC BIPOLAR PROTECTING LAYER [J].
BOGUSLAVSKY, L ;
KALASH, H ;
XU, Z ;
BECKLES, D ;
GENG, L ;
SKOTHEIM, T ;
LAURINAVICIUS, V ;
LEE, HS .
ANALYTICA CHIMICA ACTA, 1995, 311 (01) :15-21
[7]   An interference-free first generation alcohol biosensor based on a gold electrode modified by an overoxidised non-conducting polypyrrole film [J].
Carelli, D ;
Centonze, D ;
De Giglio, A ;
Quinto, M ;
Zambonin, PG .
ANALYTICA CHIMICA ACTA, 2006, 565 (01) :27-35
[8]  
Chinnadayyala S. S. R., 2012, J BIOPHYS CHEM, V3, P317, DOI DOI 10.4236/JBPC.2012.34039
[9]   Direct electrochemistry of alcohol oxidase using multiwalled carbon nanotube as electroactive matrix for biosensor application [J].
Das, Madhuri ;
Goswami, Pranab .
BIOELECTROCHEMISTRY, 2013, 89 :19-25
[10]   Graphite-Teflon composite bienzyme amperometric biosensors for monitoring of alcohols [J].
de Prada, AGV ;
Peña, N ;
Mena, ML ;
Reviejo, AJ ;
Pingarrón, JM .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (10) :1279-1288