The impact of moisture inside internal end-face gaps of optical components on the measurements quality of infrared moisture meter for sulfur hexafluoride (SF6) gas-insulated equipment (GIE) is explored. The distortion of observed absorption line shapes occurs when the background absorption spectrum of moisture existing inside internal end-face gaps of optical components at atmospheric pressure is superposed on the desired absorption spectrum of moisture in SF6 GIE where the pressure exceeds 1 atm. Errors that arise with the measurements of moisture concentration and pressure because of line shape distortion effects in infrared absorption spectroscopy are quantitatively analyzed. A correction algorithm is proposed for the dual-beam balanced ratiometric detector strategy to improve the measuring precision. This algorithm eliminates the line shape distortion effects caused by moisture inside optical components and conducts a successful moisture measurement and control program for SF6 GIE. In our experiments, the impacts of moisture inside optical components have been suppressed, and the mean absolute errors have been decreased by 86.0% and 76.1%, respectively.
引用
收藏
页码:920 / 925
页数:6
相关论文
共 13 条
[1]   ULTRASENSITIVE DUAL-BEAM ABSORPTION AND GAIN SPECTROSCOPY - APPLICATIONS FOR NEAR-INFRARED AND VISIBLE DIODE-LASER SENSORS [J].
ALLEN, MG ;
CARLETON, KL ;
DAVIS, SJ ;
KESSLER, WJ ;
OTIS, CE ;
PALOMBO, DA ;
SONNENFROH, DM .
APPLIED OPTICS, 1995, 34 (18) :3240-3249
[2]   Reduction of false alarms in forest fire surveillance using water vapour concentration measurements [J].
Bellecci, C. ;
De Leo, L. ;
Gaudio, P. ;
Gelfusa, M. ;
Lo Feudo, T. ;
Martellucci, S. ;
Richetta, M. .
OPTICS AND LASER TECHNOLOGY, 2009, 41 (04) :374-379
[3]  
Haller P. C. D., 1991, SPIE, V1435, P298, DOI DOI 10.1117/12.44253
[4]   Absolute, high resolution water transpiration rate measurements on single plant leaves via tunable diode laser absorption spectroscopy (TDLAS) at 1.37 μm [J].
Hunsmann, S. ;
Wunderle, K. ;
Wagner, S. ;
Rascher, U. ;
Schurr, U. ;
Ebert, V. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2008, 92 (03) :393-401
[5]  
Irawan R, 2000, EUROPTO SER, V4074, P175
[6]   Measurements of spectral parameters of water-vapour transitions near 1388 and 1345 nm for accurate simulation of high-pressure absorption spectra [J].
Liu, Xiang ;
Jeffries, Jay B. ;
Hanson, Ronald K. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (05) :1185-1194
[7]   The HITRAN 2008 molecular spectroscopic database [J].
Rothman, L. S. ;
Gordon, I. E. ;
Barbe, A. ;
Benner, D. Chris ;
Bernath, P. E. ;
Birk, M. ;
Boudon, V. ;
Brown, L. R. ;
Campargue, A. ;
Champion, J. -P. ;
Chance, K. ;
Coudert, L. H. ;
Dana, V. ;
Devi, V. M. ;
Fally, S. ;
Flaud, J. -M. ;
Gamache, R. R. ;
Goldman, A. ;
Jacquemart, D. ;
Kleiner, I. ;
Lacome, N. ;
Lafferty, W. J. ;
Mandin, J. -Y. ;
Massie, S. T. ;
Mikhailenko, S. N. ;
Miller, C. E. ;
Moazzen-Ahmadi, N. ;
Naumenko, O. V. ;
Nikitin, A. V. ;
Orphal, J. ;
Perevalov, V. I. ;
Perrin, A. ;
Predoi-Cross, A. ;
Rinsland, C. P. ;
Rotger, M. ;
Simeckova, M. ;
Smith, M. A. H. ;
Sung, K. ;
Tashkun, S. A. ;
Tennyson, J. ;
Toth, R. A. ;
Vandaele, A. C. ;
Vander Auwera, J. .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2009, 110 (9-10) :533-572
[8]  
Wainner R. T., 2007, P CLEO MAY, P1
[9]   Detection of water vapor concentration based on differential value of two adjacent absorption peaks [J].
Wang, Q. ;
Chang, J. ;
Zhu, C. -G. ;
Li, C. ;
Song, F. -J. ;
Liu, Y. -N. ;
Liu, X. -Z. .
LASER PHYSICS LETTERS, 2012, 9 (06) :421-425
[10]   High-sensitive measurement of water vapor: shot-noise level performance via a noise canceller [J].
Wang, Qiang ;
Chang, Jun ;
Zhu, Cunguang ;
Liu, Yongning ;
Lv, Guangping ;
Wang, Fupeng ;
Liu, Xiangzhi ;
Wang, Zongliang .
APPLIED OPTICS, 2013, 52 (05) :1094-1099