Recommendation of New Medical Alarms Based on Audibility, Identifiability, and Detectability in a Randomized, Simulation-Based Study

被引:19
作者
Bennett, Christopher [1 ]
Dudaryk, Roman [2 ]
Crenshaw, Nichole [3 ]
Edworthy, Judy [4 ]
McNeer, Richard [2 ]
机构
[1] Univ Miami, Frost Sch Mus, Mus Engn Technol, Coral Gables, FL 33124 USA
[2] Univ Miami, Miller Sch Med, Dept Anesthesiol Perioperat Med & Pain Management, Miami, FL 33136 USA
[3] Univ Miami, Sch Nursing & Hlth Studies, Coral Gables, FL 33124 USA
[4] Plymouth Univ, Cognit Inst, Plymouth, Devon, England
关键词
alarm fatigue; audible alarms; auditory alarms; medical alarms; patient monitoring; simulation; OPERATING-ROOM; NOISE;
D O I
10.1097/CCM.0000000000003802
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: Accurate and timely identification of existing audible medical alarms is not adequate in clinical settings. New alarms that are easily heard, quickly identifiable, and discernable from one another are indicated. The "auditory icons" (brief sounds that serve as metaphors for the events they represent) have been proposed as a replacement to the current international standard. The objective was to identify the best performing icons based on audibility and performance in a simulated clinical environment. Design: Three sets of icon alarms were designed using empirical methods. Subjects participated in a series of clinical simulation experiments that examined the audibility, identification accuracy, and response time of each of these icon alarms. A statistical model that combined the outcomes was used to rank the alarms in overall efficacy. We constructed the "best" and "worst" performing sets based on this ranking and prospectively validated these sets in a subsequent experiment with a new subject sample. Setting: Experiments were conducted in simulated ICU settings at the University of Miami. Subjects: Medical trainees were recruited from a convenience sample of nursing students and anesthesia residents at the institution. Interventions: In Experiment 1 (formative testing), subjects were exposed to one of the three sets of alarms; identical setting and instruments were used throughout. In Experiment 2 (summative testing), subjects were exposed to one of the two sets of alarms, assembled from the best and worst performing alarms from Experiment 1. Measurements and Main Results: For each alarm, we determined the minimum sound level to reach audibility threshold in the presence of background clinical noise, identification accuracy (percentage), and response time (seconds). We enrolled 123 medical trainees and professionals for participation (78 with < 6 yr of training). We identified the best performing icon alarms for each category, which matched or exceeded the other candidate alarms in identification accuracy and response time. Conclusions: We propose a set of eight auditory icon alarms that were selected through formative testing and validated through summative testing for adoption by relevant regulatory bodies and medical device manufacturers.
引用
收藏
页码:1050 / 1057
页数:8
相关论文
共 23 条
  • [1] Simulating environmental and psychological acoustic factors of the operating room
    Bennett, Christopher L.
    Dudaryk, Roman
    Ayers, Andrew L.
    McNeer, Richard R.
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2015, 138 (06) : 3855 - 3863
  • [2] For if the trumpet give an uncertain sound, who shall prepare himself to the battle? (I Corinthians 14:8, KJV)
    Block, Frank E., Jr.
    [J]. ANESTHESIA AND ANALGESIA, 2008, 106 (02) : 357 - 359
  • [3] PREFERRED METHOD FOR CLINICAL DETERMINATION OF PURE-TONE THRESHOLDS
    CARHART, R
    JERGER, JF
    [J]. JOURNAL OF SPEECH AND HEARING DISORDERS, 1959, 24 (04): : 330 - 345
  • [4] Methodological Quality and Reporting of Generalized Linear Mixed Models in Clinical Medicine (2000-2012): A Systematic Review
    Casals, Marti
    Girabent-Farres, Montserrat
    Carrasco, Josep L.
    [J]. PLOS ONE, 2014, 9 (11):
  • [5] Fewer but better auditory alarms will improve patient safety
    Edworthy, J
    Hellier, E
    [J]. QUALITY & SAFETY IN HEALTH CARE, 2005, 14 (03): : 212 - 215
  • [6] Edworthy J, 2017, Information design: research and practice, P377
  • [7] The impact of workload on the ability to localize audible alarms
    Edworthy, Judy
    Reid, Scott
    Peel, Katie
    Lock, Samantha
    Williams, Jessica
    Newbury, Chloe
    Foster, Joseph
    Farrington, Martin
    [J]. APPLIED ERGONOMICS, 2018, 72 : 88 - 93
  • [8] The Recognizability and Localizability of Auditory Alarms: Setting Global Medical Device Standards
    Edworthy, Judy
    Reid, Scott
    McDougall, Sine
    Edworthy, Jonathan
    Hall, Stephanie
    Bennett, Danielle
    Khan, James
    Pye, Ellen
    [J]. HUMAN FACTORS, 2017, 59 (07) : 1108 - 1127
  • [9] Heterogeneity in auditory alarm sets makes them easier to learn
    Edworthy, Judy
    Hellier, Elizabeth
    Titchener, Kirsteen
    Naweed, Anjum
    Roels, Richard
    [J]. INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2011, 41 (02) : 136 - 146
  • [10] Edworthy Judy Reed, 2017, Biomed Instrum Technol, V51, P50, DOI 10.2345/0899-8205-51.s2.50