Predictors of Complications of Endovascular Chronic Lead Extractions from Pacemakers and Defibrillators: A Single-Operator Experience

被引:75
作者
Agarwal, Sunil K. [1 ]
Kamireddy, Swapna [1 ]
Nemec, Jan [1 ]
Voigt, Andrew [1 ]
Saba, Samir [1 ]
机构
[1] Univ Pittsburgh, Med Ctr, Cardiovasc Inst, Sect Electrophysiol, Pittsburgh, PA 15213 USA
关键词
lead extraction; pacemakers; defibrillators; complications; predictors; DEVICE INFECTIONS; MANAGEMENT; RATES;
D O I
10.1111/j.1540-8167.2008.01283.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: National trends in chronic lead extractions from cardiac rhythm management (CRM) devices are on the rise. Objective: The main objective of the study was to identify the predictors of complications of chronic lead extractions. Methods: All patients who underwent endovascular chronic CRM lead extraction at our institution between 2002 and 2008 were included in this analysis. Demographic data as well as details of the extraction procedure and its complications within the ensuing 30 days were collected on all patients. Results: Data of 212 consecutive patients (456 leads, age = 65 +/- 17 years, men 75%, left ventricular ejection fraction = 36 +/- 16%, coronary artery disease 80%, defibrillators 49%) were analyzed. There were a total of 26 (11.8%) complications in 25 patients including 9 (4.2%) major complications (death 1, hemothorax 4, pneumothorax 2, tamponade 1, stroke 1) and 17 (8.0%) minor complications. Independent predictors of any complications included a higher number of explanted right ventricular leads (HR = 3.51, P = 0.013). Explantation of ICD as opposed to a pacemaker device showed a strong trend toward significance (HR = 2.57, P = 0.053). An elevated white blood cell count also predicted major complications (HR = 1.52, P = 0.005). Conclusion: Predictors of complications after lead extraction procedures include a higher number of extracted leads and the presence of defibrillator as opposed to pacemaker leads. A new paradigm of the removal of all leads not connected to a device may, therefore, reduce the risk of complications from lead extraction procedures and deserves to be tested prospectively. (J Cardiovasc Electrophysiol, Vol. 20, pp. 171-175, February 2009).
引用
收藏
页码:171 / 175
页数:5
相关论文
共 11 条
[1]   Nonvalvular cardiovascular device-related infections [J].
Baddour, LM ;
Bettmann, MA ;
Bolger, AF ;
Epstein, AE ;
Ferrieri, P ;
Gerber, MA ;
Gewitz, MH ;
Jacobs, AK ;
Levison, ME ;
Newburger, JW ;
Pallasch, TJ ;
Wilson, WR ;
Baltimore, RS ;
Falace, DA ;
Shulman, ST ;
Tani, LY ;
Taubert, KA .
CIRCULATION, 2003, 108 (16) :2015-2031
[2]   Pacemaker lead complications: when is extraction appropriate and what can we learn from published data? [J].
Bracke, FA ;
Meijer, A ;
van Gelder, LM .
HEART, 2001, 85 (03) :254-258
[3]   Increasing rates of cardiac device infections among Medicare beneficiaries: 1990-1999 [J].
Cabell, CH ;
Heidenreich, PA ;
Chu, VH ;
Moore, CM ;
Stryjewski, ME ;
Corey, GR ;
Fowler, VG .
AMERICAN HEART JOURNAL, 2004, 147 (04) :582-586
[4]   Diagnosis and management of infections involving implantable electrophysiologic cardiac devices [J].
Chua, JD ;
Wilkoff, BL ;
Lee, I ;
Juratli, N ;
Longworth, DL ;
Gordon, SM .
ANNALS OF INTERNAL MEDICINE, 2000, 133 (08) :604-608
[5]   Laser lead extraction: Is there a learning curve? [J].
Ghosh, N ;
Yee, R ;
Klein, GJ ;
Quantz, M ;
Novick, RJ ;
Skanes, AC ;
Krahn, AD .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (03) :180-184
[6]   Large, single-center, single-operator experience with transvenous lead extraction: Outcomes and changing indications [J].
Jones, Samuel O. ;
Eckart, Robert E. ;
Albert, Christine M. ;
Epstein, Laurence M. .
HEART RHYTHM, 2008, 5 (04) :520-525
[7]   Risk factors related to infections of implanted pacemakers and cardioverter-defibrillators - Results of a large prospective study [J].
Klug, Didier ;
Balde, Mamadou ;
Pavin, Dominique ;
Hidden-Lucet, Francoise ;
Clementy, Jacques ;
Sadoul, Nicolas ;
Rey, Jean Luc ;
Lande, Gilles ;
Lazarus, Arnaud ;
Victor, Jacques ;
Barnay, Claude ;
Grandbastien, Bruno ;
Kacet, Salem .
CIRCULATION, 2007, 116 (12) :1349-1355
[8]   Pacemaker and defibrillator lead extraction [J].
Kutalek, SP .
CURRENT OPINION IN CARDIOLOGY, 2004, 19 (01) :19-22
[9]  
Love CJ, 2000, PACE, V23, P544
[10]   Cardiac pacemaker lead extraction using conventional techniques: a single centre experience [J].
Mathur, G ;
Stables, RH ;
Heaven, D ;
Stack, Z ;
Lovegrove, A ;
Ingram, A ;
Sutton, R .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2003, 91 (2-3) :215-219