Ion coalescence in Fourier transform mass spectrometry: should we worry about this in shotgun proteomics?

被引:13
作者
Tarasova, Irina A. [1 ]
Surin, Alexey K. [2 ]
Fornelli, Luca [3 ]
Pridatchenko, Marina L. [1 ]
Suvorina, Mariya Yu. [2 ]
Gorshkov, Mikhail V. [1 ,4 ]
机构
[1] Russian Acad Sci, VL Talrose Inst Energy Problems Chem Phys, Moscow 119334, Russia
[2] Russian Acad Sci, Inst Prot Res, Pushchino 142292, Moscow Region, Russia
[3] Ecole Polytech Fed Lausanne, Inst Chem Sci & Engn, CH-1015 Lausanne, Switzerland
[4] Moscow Inst Phys & Technol, Dolgoprudnyi 141700, Moscow Region, Russia
基金
俄罗斯科学基金会;
关键词
orbitrap; ion coalescence; shotgun proteomics; ASPARTATE ISOMERIZATION; ASPARAGINE DEAMIDATION; DYNAMIC-RANGE; RESOLUTION; SPACE; PEPTIDES; ACCURACY; TRAP; CELL;
D O I
10.1255/ejms.1356
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Coupling of motion of the ion clouds with close m/z values is a well-established phenomenon for ion-trapping mass analyzers. In Fourier transform ion cyclotron resonance mass spectrometry it is known as ion coalescence. Recently, ion coalescence was demonstrated and semiquantitatively characterized for the Orbitrap mass analyzer as well. When it occurs, the coalescence negatively affects the basic characteristics of a mass analyzer. Specifically, the dynamic range available for the high resolving power mass measurements reduces. In shotgun proteomics, another potentially adverse effect of ion coalescence is interference of the isotopic envelopes for the coeluting-precursor ions of close m/z values, subjected to isolation before fragmentation. In this work we characterize coalescence events for synthetic-peptide mixtures with fully and partially overlapping C-13-isotope envelopes, including pairs of peptides with glutamine-deamidation. Furthermore, we demonstrate that fragmentation of the otherwise coalesced peptide ion clouds may remove the locking between them owing to the total charge redistribution between more ion species in the mass spectrum. Finally, we estimated the possible-scale of the coalescence phenomenon for shotgun proteomics by considering the fraction of coeluted peptide pairs with the close masses using literature data for the yeast proteome. It was found that up to one-tenth of all peptide identifications with the relative mass differences of 20 ppm or less in the corresponding pairs may potentially experience the coalescence of the C-13-isotopic envelopes. However, sample complexity in a real proteomics experiment and precursor ion-signal splitting between many channels in tandem mass spectrometry drastically increase the threshold for coalescence, thus leading to practically coalescence-free proteomics based on Fourier transform mass spectrometry.
引用
收藏
页码:459 / 470
页数:12
相关论文
共 32 条
[1]   Mass spectrometry-based proteomics [J].
Aebersold, R ;
Mann, M .
NATURE, 2003, 422 (6928) :198-207
[2]   An electrically compensated trap designed to eighth order for FT-ICR mass Spectrometry [J].
Brustkern, Adam M. ;
Rempel, Don L. ;
Gross, Michael L. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2008, 19 (09) :1281-1285
[3]   Proteomics on an Orbitrap Benchtop Mass Spectrometer Using All-ion Fragmentation [J].
Geiger, Tamar ;
Cox, Juergen ;
Mann, Matthias .
MOLECULAR & CELLULAR PROTEOMICS, 2010, 9 (10) :2252-2261
[4]   Observation of ion coalescence in Orbitrap Fourier transform mass spectrometry [J].
Gorshkov, Mikhail V. ;
Fornelli, Luca ;
Tsybin, Yury O. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (15) :1711-1717
[5]   Calibration Function for the Orbitrap FTMS Accounting for the Space Charge Effect [J].
Gorshkov, Mikhail V. ;
Good, David M. ;
Lyutvinskiy, Yaroslav ;
Yang, Hongqian ;
Zubarev, Roman A. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2010, 21 (11) :1846-1851
[6]   Baseline mass resolution of peptide isobars: A record for molecular mass resolution [J].
He, F ;
Hendrickson, CL ;
Marshall, AG .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :647-650
[7]   The One Hour Yeast Proteome [J].
Hebert, Alexander S. ;
Richards, Alicia L. ;
Bailey, Derek J. ;
Ulbrich, Arne ;
Coughlin, Emma E. ;
Westphall, Michael S. ;
Coon, Joshua J. .
MOLECULAR & CELLULAR PROTEOMICS, 2014, 13 (01) :339-347
[8]   The dynamic range problem in the analysis of the plasma proteome [J].
Hortin, Glen L. ;
Sviridov, Denis .
JOURNAL OF PROTEOMICS, 2010, 73 (03) :629-636
[9]   Differentiation of isomeric amino acid residues in proteins and peptides using mass spectrometry [J].
Hurtado, Pilar Perez ;
O'Connor, Peter B. .
MASS SPECTROMETRY REVIEWS, 2012, 31 (06) :609-625
[10]   Empirical Multidimensional Space for Scoring Peptide Spectrum Matches in Shotgun Proteomics [J].
Ivanov, Mark V. ;
Levitsky, Lev I. ;
Lobas, Anna A. ;
Panic, Tanja ;
Laskay, Uenige A. ;
Mitulovic, Goran ;
Schmid, Rainer ;
Pridatchenko, Marina L. ;
Tsybin, Yury O. ;
Gorshkov, Mikhail V. .
JOURNAL OF PROTEOME RESEARCH, 2014, 13 (04) :1911-1920