Management of a long segmental defect at the proximal meta-diaphyseal junction of the tibia using a cylindrical titanium mesh cage

被引:47
作者
Ostermann, PAW [1 ]
Haase, N
Rübberdt, A
Wich, M
Ekkernkamp, A
机构
[1] St Agnes Hosp, Dept Traumatol, Bocholt, Germany
[2] Unfallkrankenhaus, Berlin, Germany
[3] Ernst Moritz Arndt Univ Greifswald, Greifswald, Germany
关键词
segmental bone loss; titanium mesh cage; third-generation intramedullary nail;
D O I
10.1097/00005131-200209000-00010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This case report describes a Gustilo Anderson type IIIB tibia fracture associated with extensive segmental bone loss at the proximal meta-diaphyseal junction associated with a tibial plateau fracture and an avulsion of the tibial tubercle. After the tibial plateau fracture was stabilized using cannulated lag screws, the shaft fracture was stabilized using a statically locked intramedullary nail in combination with a cylindrical titanium mesh cage and cancellous bone graft. The soft tissue defect was covered with local flaps. Immediate full weight bearing was initiated, and early functional recovery was achieved. At the final follow-up, plain radiographs demonstrated excellent limb alignment, and bony healing with computed tomography examination revealed bony ingrowth through the cage. This technique may be a reasonable alternative in the treatment of segmental bone loss of long bones.
引用
收藏
页码:597 / 601
页数:5
相关论文
共 14 条
[1]   Arthrodesis of the ankle with a free vascularized autogenous bone graft - Reconstruction of segmental loss of bone secondary to osteomyelitis, tumor, or trauma [J].
Bishop, AT ;
Wood, MB ;
Sheetz, KK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (12) :1867-1875
[2]  
BRUNNER UH, 1994, CLIN ORTHOPAEDICS, V301, P147
[3]   STRUCTURAL ALLOGRAFTS FOR RECONSTRUCTION OF LOWER-EXTREMITY OPEN FRACTURES WITH 10 CENTIMETERS OR MORE OF ACUTE SEGMENTAL DEFECTS [J].
CHMELL, MJ ;
MCANDREW, MP ;
THOMAS, R ;
SCHWARTZ, HS .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1995, 9 (03) :222-226
[4]  
CIERNY G, 1994, CLIN ORTHOP RELAT R, V301, P118
[5]   The cylindrical titanium mesh cage for treatment of a long bone segmental defect: Description of a new technique and report of two cases [J].
Cobos, JA ;
Lindsey, RW ;
Gugala, Z .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (01) :54-59
[6]  
DAHL MT, 1994, CLIN ORTHOP RELAT R, V301, P10
[7]   RECONSTRUCTION OF SKELETAL DEFECTS IN THE FOREARM AFTER TRAUMA - TREATMENT WITH CEMENT SPACER AND DELAYED CANCELLOUS BONE-GRAFTING [J].
GEORGIADIS, GM ;
DESILVA, SP .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1995, 38 (06) :910-914
[8]   THE INFLUENCE OF INDUCED MICROMOVEMENT UPON THE HEALING OF EXPERIMENTAL TIBIAL FRACTURES [J].
GOODSHIP, AE ;
KENWRIGHT, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (04) :650-655
[9]  
GREEN SA, 1994, CLIN ORTHOP RELAT R, V301, P111
[10]   PROBLEMS IN THE MANAGEMENT OF TYPE-III (SEVERE) OPEN FRACTURES - A NEW CLASSIFICATION OF TYPE-III OPEN FRACTURES [J].
GUSTILO, RB ;
MENDOZA, RM ;
WILLIAMS, DN .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1984, 24 (08) :742-746