Reproducibility of resting peripheral blood flow using strain gauge plethysmography

被引:11
作者
Fehling, PC [1 ]
Arciero, PJ [1 ]
MacPherson, CJ [1 ]
Smith, DL [1 ]
机构
[1] Skidmore Coll, Dept Exercise Sci & Dance, Saratoga Springs, NY 12866 USA
关键词
venous occlusion plethysmography; arterial inflow; plethysmograph; reproducibility; reliability;
D O I
10.1055/s-1999-8845
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The purpose of this study was to examine the intra-tester and inter-tester reliability of strain gauge plethysmography (SGP) using the Hokanson EC-5R plethysmograph among three investigators. An arterial inflow test was performed by each of the investigators on fifteen college-aged volunteers at the forearm and calf sites. Intra-tester reliability was assessed by analyzing three serial measurements obtained at both sites. Intertester reliability was assessed in two ways: first, by having the three investigators obtain and analyze their own recordings, and, second, by having all three investigators (Testers 1, 2, and 3) analyze SGP recordings obtained by the most experienced investigator (Tester 1). The mean coefficient of variation (CV) for the intra-tester analysis was similar at the forearm (4.9%) and calf (4.0%) sites. The inter-tester analysis revealed that there were no significant differences among the three testers at either site when investigators obtained and analyzed their own waveforms. The CV calculated from the means of the three investigators was greater at the forearm site (10.7 %) than at the calf site (2.5 %). Similarly, when Testers 2 and 3 analyzed Tester 1's waveforms there were no significant differences found among testers at either site and the CV was less than when each investigator obtained his/her own waveforms. Strain gauge plethysmography blood flow measures obtained by experienced testers, under controlled laboratory conditions, are reproducible. The small variability in blood flow that exists is more attributable to variability in the acquisition of the waveforms than in the analysis of the waveforms.
引用
收藏
页码:555 / 559
页数:5
相关论文
共 21 条
  • [1] ALTENKIRCH HU, 1989, VASA-J VASCULAR DIS, V18, P140
  • [2] Effects of short-term inactivity on glucose tolerance, energy expenditure, and blood flow in trained subjects
    Arciero, PJ
    Smith, DL
    Calles-Escandon, J
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1998, 84 (04) : 1365 - 1373
  • [3] BLACK JE, 1959, CLIN SCI, V18, P89
  • [4] CLARKE RSJ, 1957, CLIN SCI, V16, P103
  • [5] DOYLE DL, 1986, CAN J SURG, V29, P338
  • [6] VASCULAR-RESPONSES IN FOREARM AND CALF TO CONTRALATERAL STATIC EXERCISES
    DUPREZ, DA
    ESSANDOH, LK
    VANHOUTTE, PM
    SHEPHERD, JT
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1989, 66 (02) : 669 - 674
  • [7] EICKHOFF JH, 1980, ACTA CHIR SCAND, P15
  • [8] ELSNER RW, 1962, J APPL PHYS, V17, P436
  • [9] IMPAIRED THERMOREGULATION IN RAYNAUDS-PHENOMENON
    GREENSTEIN, D
    GUPTA, NK
    MARTIN, P
    WALKER, DR
    KESTER, RC
    [J]. ANGIOLOGY, 1995, 46 (07) : 603 - 611
  • [10] DOUBLE-BLIND CLINICAL AND PLETHYSMOGRAPHIC STUDY OF CALCIUM DOBESILATE IN PATIENTS WITH PERIPHERAL MICRO-VASCULAR DISORDERS
    HACHEN, HJ
    LORENZ, P
    [J]. ANGIOLOGY, 1982, 33 (07) : 480 - 488