Gas-diffusion microextraction coupled with spectrophotometry for the determination of formaldehyde in cork agglomerates

被引:16
作者
Brandao, Pedro F. [1 ]
Ramos, Rui M. [1 ]
Valente, Ines M. [1 ,2 ]
Almeida, Paulo J. [1 ]
Carro, Antonia M. [3 ]
Lorenzo, Rosa A. [3 ]
Rodrigues, Jose A. [1 ]
机构
[1] Univ Porto, Fac Ciencias, REQUIMTE LAQV Dept Quim & Bioquim, Rua Campo Alegre,687, P-4169007 Oporto, Portugal
[2] Univ Porto, Inst Ciencias Biomed Abel Salazar, REQUIMTE LAQV ICBAS Dept Clin Vet, R Jorge Viterbo Ferreira 228, P-4050343 Oporto, Portugal
[3] Univ Santiago de Compostela, Dept Quim Analit Nutr & Bromatol, Fac Quim, Inst Invest Sanitaria Santiago de Compostela IDIS, Avda Ciencias,S-N Campus Sur, Santiago De Compostela 15782, Spain
关键词
Experimental design; Formaldehyde; Gas-diffusion microextraction; Indoor air quality; Visible spectrophotometry; Wood-based products; EMISSION; WOOD; ALDEHYDES; RESINS; WINE;
D O I
10.1007/s00216-017-0233-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, a simple methodology was developed for the extraction and determination of free formaldehyde content in cork agglomerate samples. For the first time, gas-diffusion microextraction was used for the extraction of volatile formaldehyde directly from samples, with simultaneous derivatization with acetylacetone (Hantzsch reaction). The absorbance of the coloured solution was read in a spectrophotometer at 412 nm. Different extraction parameters were studied and optimized (extraction temperature, sample mass, volume of acceptor solution, extraction time and concentration of derivatization reagent) by means of an asymmetric screening. The developed methodology proved to be a reliable tool for the determination of formaldehyde in cork agglomerates with the following suitable method features: low LOD (0.14 mg kg(-1)) and LOQ (0.47 mg kg(-1)), r(2) = 0.9994, and intraday and interday precision of 3.5 and 4.9%, respectively. The developed methodology was applied to the determination of formaldehyde in different cork agglomerate samples, and contents between 1.9 and 9.4mg kg(-1) were found. Furthermore, formaldehyde was also determined by the standard method EN 717-3 for comparison purposes; no significant differences between the results of both methods were observed.
引用
收藏
页码:2885 / 2892
页数:8
相关论文
共 41 条
[1]   ORTHOGONAL MAIN-EFFECT PLANS FOR ASYMMETRICAL FACTORIAL EXPERIMENTS [J].
ADDELMAN, S .
TECHNOMETRICS, 1962, 4 (01) :21-+
[2]  
[Anonymous], 1994, 7172 EN
[3]  
[Anonymous], 1996, 7173 EN
[4]  
[Anonymous], 322 EN
[5]  
[Anonymous], A1460 JIS
[6]  
[Anonymous], [No title captured]
[7]  
[Anonymous], NEMRODW VRSION 2011
[8]  
[Anonymous], 2006, IARC MONOGRAPHS EVAL
[9]  
[Anonymous], 2004, 7171 EN
[10]   Analysis of industrial contaminants in indoor air: Part 1. Volatile organic compounds, carbonyl compounds, polycyclic aromatic hydrocarbons and polychlorinated biphenyls [J].
Barro, Ruth ;
Regueiro, Jorge ;
Llompart, Maria ;
Garcia-Jares, Carmen .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (03) :540-566