Occupational Electromagnetic Fields exposure in Magnetic Resonance Imaging systems - Preliminary results for the RF harmonic content

被引:12
作者
Gourzoulidis, G. [1 ,4 ]
Karabetsos, E. [2 ]
Skamnakis, N. [2 ]
Xrtistodoulou, A. [3 ]
Kappas, C. [4 ]
Theodorou, K. [4 ]
Tsougos, I. [4 ]
Maris, T. G. [5 ]
机构
[1] Hellen Minist Labor, OHS Directorate, Hazardous Agents Dept, Athens, Greece
[2] Greek Atom Energy Commiss, Nonionizing Radiat Off, Attika, Greece
[3] Hellen Minist Labor, OHS, Athens, Greece
[4] Univ Thessaly, Sch Hlth Sci, Fac Med, Dept Med Phys, Thessaly, Greece
[5] Univ Crete, Fac Med, Dept Med Phys, Iraklion, Greece
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2015年 / 31卷 / 07期
关键词
Electromagnetic fields; MRI occupational safety; Risk assessment; Occupational health and safety; MRI SCANNERS;
D O I
10.1016/j.ejmp.2015.03.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: European legislation concerning the protection of workers from exposure to Electromagnetic Fields (EMF) was recently (26.6.2013) completed by Directive 2013/35/.U. This Directive is a specific one of the framework Directive 89/391/EEC and part of the overall legislation for Occupational Health and Safety (OHS). Magnetic Resonance Imaging (MRI) systems have played a key role, both in the postponement of the former 2004/40 EMF Directive and in the formation of the latest limits adopted by the new Directive. On the other hand, MRI systems are associated with the exposure of personnel to EMF of various frequencies and modulations, arousing peculiar safety issues. Therefore, we will try to acquire the highly important knowledge of the exact occupational exposure levels, in all working scenarios and practices. Methods: Different MRI systems (1.5 and 3 T) have been chosen for a variety of measurements in order to assess occupational exposure compared to the limits (ALs) of the Directive and to the main OHS principles. Gradient function of MRI systems results in low frequency exposure, while high frequency exposure comes from the application of the RF excitation frequency. Results: In most of the cases the RMS and peak value measurements do not exceed the corresponding ALs, apart from a few specific hot spots, manageable through OHS principles. Discussion: Complete occupational exposure results can form the basis for dealing with multiple exposures present in MRI systems. Peculiar RF harmonic components, of no safety concern, were detected. Their origin is under examination. (C) 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:757 / 762
页数:6
相关论文
共 14 条
[1]  
Ahlbom A, 1998, HEALTH PHYS, V74, P494
[2]  
[Anonymous], 2013, Off. J. Eur. Union L
[3]  
[Anonymous], 60601233 IEC
[4]   Pooled analyses of effects on visual and visuomotor performance from exposure to magnetic stray fields from MRI scanners: Application of the Bayesian framework [J].
de Vocht, Frank ;
Glover, Paul ;
Engels, Hans ;
Kromhout, Hans .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (05) :1255-1260
[5]   Impact of cardiac magnetic resonance imaging on human lymphocyte DNA integrity [J].
Fiechter, Michael ;
Stehli, Julia ;
Fuchs, Tobias A. ;
Dougoud, Svetlana ;
Gaemperli, Oliver ;
Kaufmann, Philipp A. .
EUROPEAN HEART JOURNAL, 2013, 34 (30) :2340-2345
[6]   Effects of Static Magnetic Fields on Cognition, Vital Signs, and Sensory Perception: A Meta-analysis [J].
Heinrich, Angela ;
Szostek, Anne ;
Nees, Frauke ;
Meyer, Patric ;
Semmler, Wolfhard ;
Flor, Herta .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (04) :758-763
[7]  
Huettel SA, 2014, FUNCTIONAL MAGNETIC RESONANCE IMAGING, THIRD EDITION, P31
[8]   ACR guidance document on MR safe practices: 2013 [J].
Kanal, Emanuel ;
Barkovich, A. James ;
Bell, Charlotte ;
Borgstede, James P. ;
Bradley, William G., Jr. ;
Froelich, Jerry W. ;
Gimbel, J. Rod ;
Gosbee, John W. ;
Kuhni-Kaminski, Ellisa ;
Larson, Paul A. ;
Lester, James W., Jr. ;
Nyenhuis, John ;
Schaefer, Daniel Joe ;
Sebek, Elizabeth A. ;
Weinreb, Jeffrey ;
Wilkoff, Bruce L. ;
Woods, Terry O. ;
Lucey, Leonard ;
Hernandez, Dina .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (03) :501-530
[9]  
Karabetsos E, 2014, 8 EFOMP ATH GREEC
[10]  
Karabetsos E, 2014, 8 INT WORKSH BIOL EF