Unimolecular decomposition in ion cyclotron resonance traps: kinetic energy release and microsecond-scale kinetics

被引:2
作者
Rakov, VS [1 ]
Futrell, JH [1 ]
机构
[1] Pacific NW Natl Lab, Environm & Mol Sci Lab, Richland, WA 99352 USA
关键词
kinetic energy cyclotron spectroscopy; unimolecular decay; kinetic energy release; microsecond-scale kinetics; active complex lifetime; dynamic voltage trapping; surface-induced dissociation;
D O I
10.1255/ejms.497
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A method of recovering information about the kinetics and dynamics of gas-phase ion-molecule reactions which occur on a microsecond time scale inside a Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR-MS) cell is presented. In FT-ICR experiments, the typical time-scale of the ion detection is of the order of milliseconds to seconds and the microsecond-scale reactions usually run to completion before the detection takes place. However, axial oscillation inside the ICR cell can be made very fast and the efficiency of the dynamic voltage trapping depends on the axial position of the ions. We present a theoretical model which relates experimental ion abundance to the life-times and kinetic energy releases, illustrating it with an example of fast-decomposing chromium hexacarbonyl molecular cation activated by collision with a fluorinated self-assembled monolayer surface in a 7-Tesla FT-ICR cell. General formalism, quantitative limitations and application of this method to measure lifetimes and the kinetic energy releases of less-studied ionic systems are addressed in detail.
引用
收藏
页码:253 / 262
页数:10
相关论文
共 35 条
[1]   ION CYCLOTRON RESONANCE SPECTROSCOPY [J].
BALDESCHWIELER, JD .
SCIENCE, 1968, 159 (3812) :263-+
[2]   MEASUREMENT OF ION MOLECULE REACTIONS BETWEEN 10-K AND 20-K [J].
BARLOW, SE ;
LUINE, JA ;
DUNN, GH .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1986, 74 (01) :97-128
[3]   ION CYCLOTRON RESONANCE SPECTROSCOPY [J].
BEAUCHAM.JL .
ANNUAL REVIEW OF PHYSICAL CHEMISTRY, 1971, 22 :527-&
[4]   AN ION EJECTION TECHNIQUE FOR STUDY OF ION-MOLECULE REACTIONS WITH ION CYCLOTRON RESONANCE SPECTROSCOPY [J].
BEAUCHAMP, JL ;
ARMSTRONG, JT .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1969, 40 (01) :123-+
[5]   THEORY OF ION-CYCLOTRON RESONANCE [J].
BLOOM, M ;
RIGGIN, M .
CANADIAN JOURNAL OF PHYSICS, 1974, 52 (05) :436-455
[6]  
BUTRILL SE, 1969, J CHEM PHYS, V50, P4125
[7]   ION VELOCITY DISTRIBUTIONS IN AN ICR SPECTROMETER AND THEIR EFFECT ON MEASURED RATE CONSTANTS [J].
CHESNAVICH, WJ ;
SU, T ;
BOWERS, MT .
JOURNAL OF CHEMICAL PHYSICS, 1976, 65 (03) :990-997
[8]  
Clow R. P., 1970, INT J MASS SPECTROM, V4, P165
[9]   FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE SPECTROSCOPY [J].
COMISAROW, MB ;
MARSHALL, AG .
CHEMICAL PHYSICS LETTERS, 1974, 25 (02) :282-283
[10]   FRAGMENTATION OF ENERGY-SELECTED HEXACARBONYLCHROMIUM ION [J].
DAS, PR ;
NISHIMURA, T ;
MEISELS, GG .
JOURNAL OF PHYSICAL CHEMISTRY, 1985, 89 (13) :2808-2812